Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Drying time Recorder> TQC sheen> TQC sheen AB3600 Drying Time Recorder
      TQC sheen AB3600 Drying Time Recorder

      TQC sheen AB3600 Drying Time Recorder BK method, six-track -20 ℃ to 70 ℃ test

      Equipped with six independent tracks and a heated display, the operation temperature range is -20 ° C to 70 ° C, the time setting accuracy error is less than 1%, and it supports a wide range of drying time testing requirements from 1 minute to 200 hours.

      Brand
      SKU: NB022276
      Netherlands TQC sheen
      Model
      Stock
      Loading…
      Price
      $ 4189.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • TQC sheen AB3600 Drying Time RecorderOverview

        • Specifications
        • Comments
        • FAQs
        AB3600
        Drying Time Recorder
        • TQC sheen AB3600 Drying Time Recorder BK method, six-track -20 ℃ to 70 ℃ test
        Equipped with six independent tracks and a heated display, the operation temperature range is -20 ° C to 70 ° C, the time setting accuracy error is less than 1%, and it supports a wide range of drying time testing requirements from 1 minute to 200 hours.

        Introduction

        The drying time Recorder is a fully digitally controlled machine that is used to define the different stages of the paint and coating drying process. The drying time Recorder conforms to the BK (Beck Koller) method. With a clear digital display and an intuitive interface, it is very easy to define the final result or check the intermediate stages. The compact machine complies with ASTM D5895, ISO 9117-4 and DIN EN 14022.The drying time Recorder has six tracks and is equipped with two robust and reusable 100 x 350 x 3 mm glass beds. Six narrow glass beds with special adapters are available as an option.

        The front panel of the dry time logger is made of clear glass, which is easy to clean and protects the display underneath it. The drying time logger is powered by a safe 24 V DC power supply.

        Temperature-friendly design

        The possibility of testing at temperatures as low as -20°C is unique. The drive system is lubricant-free, so there is no risk of lubricant thickening at lower temperatures. The display is heated to improve menu visibility at lower temperatures. These design features allow for an operating temperature range from -20°C to +70°C (non-condensing), which allows testing in a climate chamber.

        Broad and flexible time frames

        The wide and flexible time range can be set from 1 minute to 200 hours. This makes the drying time logger suitable for fast-drying water-based paints as well as very slow drying paints that can take days to dry. The time setting is very accurate, < 1% of the set time.

        Dutch TQC drying time Recorder AB3600 display diagram

        VS

        TQC sheen AB3600 Drying Time RecorderSpecifications

        LIST VALUE
        Number of strokes 6 stitches
        Scribing needle specification Φ2mm;R 1mm
        Travel 300mm
        Drying time range 1 minute - 200 hours
        execution standard ASTM D5895, ISO 9117-4 and DIN EN 14022
        Motor power Universal 24 V DC Power Adapter, 40W
        dimensions 335*400*190mm
        operating temperature -20 ° C - 70 ° C/-4 ° F - 158 ° F (non-condensing)
        time accuracy < 1% of the set time
        Glass bed 2 x three rails 305 mm x 100 mm x 3 mm (available), or 6 x independent rails 305 mm x 25 mm x 3 mm narrow Glass bed or custom bed, maximum dimensions W 200 mm, H 8 mm, L 400 mm
        block 9.5 kilograms/20.94 pounds
        material Anodic oxidation Aluminum, Glass, Nylon, Powder coated steel, Stainless steel
        show 128 x 64 pixel graphic LCD, 70 mm x 40 mm, white lighting, heated
        language English
        input method Illuminated tactile navigation button with triple function

        TQC sheen AB3600 Drying Time Recorder Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +TQC sheen AB3600 Drying Time Recorder Big data
          +TQC sheen AB3600 Drying Time RecorderSimilar products
          +TQC sheen AB3600 Drying Time RecorderKnowledge
          +TQC sheen AB3600 Drying Time RecorderStandard
          +Navigation
          TQC sheen
          TQC sheen AB3600 Drying Time Recorder BK method, six-track -20 ℃ to 70 ℃ test
          Service
          Focus on online sales of Lab Testing Instruments