HZAOC hzaoc GDJS-010A Temperature Humidity Cyclic Chamber -20~150 ℃/1000L
HZAOC hzaocGDJS-010A Temperature Humidity Cyclic Chamber liner is made of imported 304 stainless steel, GDJS-010A adopts imported touch screen temperature control instrument, Interior size is 1000 × 1000 × 1000mm.
hzaoc-
HZAOC GDJS-010E high-low temperature Humidity Cyclic Chamber -70~150 ℃/1000L
$ 13658.00 -
YIHENG BPHJS-1000B High-low temperature alternating damping heat Test Chamber -40~130 ℃/1000L
$ 15856.00 -
YIHENG BPS-500CA constant temperature and Humidity Test Chamber -20~100 ℃/500L
$ 7677.00 -
Factory Direct NBC-1000L-70 programmable constant temperature and humidity testing machine, paint board 1000L -70~150 ℃
$ 7066.00 -
ZKHS GDJS-800C high-low temperature Humidity Cyclic Chamber -40~150 ℃/800L
$ 12072.00
Introduction
The product is suitable for the investigation of electrical and electronic products, components, parts and materials under different temperature and humidity conditions, its moisture resistance, and can also be used as an adaptability test for storage, transportation and use in high-low temperature environments.
Cabinet structure
1. The whole box adopts an integral structure.
2. The inner side of the box is made of 1.0mm SUS304B stainless steel plate, and the outer side is sprayed with 1.0mm cold-rolled steel plateThe warm material is made of ultra-fine glass insulation foam.
3. The door seal is made of double-layer silicone rubber sealing material.
4. The observation window is multi-layer conductive film tempered insulating glass, and the size is 250×260mm to prevent low temperatureThe glass is frosted, surrounded by a built-in special heating wire, and illuminated by a light to provide illumination for observation.
5. There is a φ50mm test hole with a plug on the side of the box, and the plug material is silicone rubber with low foaming, which is durableHigh-low temperature, both thermal insulation effect.
6. An air conditioning cabinet is arranged at the back of the box studio, and evaporators, electric heaters, andHumidifiers, fans, fan volutes and other equipment.
7. The temperature sensor is placed at the air outlet.
8. The air supply mode in the Test Chamber is the upper air supply and lower return air mode.

Heating and humidification systems
1. The heater adopts porcelain frame nickel-chromium wire electric heater, which has low thermal inertia and long life. The controllable pulse duty cycle PID signal is output by the instrument, which is controlled by a solid-state relay, and the control is stable and reliable.
2. Steam boiler electric heating humidification method, armored electric heating tube, PID control mode, using non-contact periodic pulse widening SSR (solid state relay) control, equipped with water level control device, heater anti-dry burning device.
Control system
1. Temperature controller: LCD touch screen temperature and humidity controller
2. Sensor: PT100 temperature sensor.
3. The control heating output is triggered by solid-state relay zero-crossing to reduce noise, reduce pollution, facilitate maintenance, and improve control accuracy.
4. Safety protection measures should be set up in the control system, including: phase loss protection, phase sequence error protection, phase Voltage uneven protection, fan overload protection, over-temperature power-off protection, leakage and other protection.
5. The control system is equipped with a user-friendly operation panel, which is located in the upper left part of the Test Chamber, and is equipped with power supply, lighting, operation buttons for various functions and fault indicators.
6. In addition to the main controller in the system, an independent over-temperature protector is also set up, even if the main controller fails, the over-temperature protector can reliably disconnect the heating power supply to protect the safety of equipment and samples.
7. There is an interlock device in the electrical control system, and the heating and humidification system cannot be started when the circulating fan is not started or overloaded.
Enforce the standard
1.GB/T2423.3-2001
2.GB/T5170.5-96;
3.GB/T10586-89;
hzaoc GDJS-010A Temperature Humidity Cyclic ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -20~150℃ |
| Temperature Fluctuation | ≤±0.5℃ |
| Temperature Uniformity | ≤±2℃ |
| Humidity Control Range | 30~98%R.H |
| Power supply Voltage | AC380V |
| Interior size | 1000*1000*1000mm |
| Dimensions | 1610*1560*1960mm |
| Interior Volume | 1000L |
| Humidity Uniformity | +2%-3%R.H |
| Humidity stability | ±2%R.H |
| Power | 3~15KW |
hzaoc GDJS-010A Temperature Humidity Cyclic Chamber Packing list
host x1, sample holder x1, silicone plug x1, Humidity gauze x1, warranty card x1, manual x1, certificate x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveIEC
- ActiveIEC
- ActiveASTM
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveQX/T 16-2020
- ActiveJG/T 25-2017
- ActiveGB/T 43489-2023
- ActiveGB/T 4893.8-2023
- ActiveGB/T 23711.2-2019
- AbolishGB/T 2424.5-2006
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 32065.6-2015
- Active 10590-2006
- ActiveGB/T 2423.4-2008
- ActiveGB/T 41166-2021


GDJS-010A