Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Formaldehyde Climatic Chamber> Moderner> Moderner XD-1JQ-F1 Determination of formaldehyde release climate Chamber
      Moderner XD-1JQ-F1 Determination of formaldehyde release climate Chamber

      MODERNER XD-1JQ-F1 1m3 formaldehyde release determination Climate Chamber, top matching type

      MODERNER XD-1JQ-F1 formaldehyde release measurement Climate Chamber temperature control range is + 20 ℃~ + 35 ℃, background formaldehyde mass concentration ≤ 0.006mg/m3, XD-1JQ-F1 is a test material can determine the environment variables VOC release and release characteristics of the influence of formaldehyde release measurement Climate Chamber.

      Brand
      SKU: NB022851
      China Moderner
      VS
      Information
      Genuinegoods
      • Moderner XD-1JQ-F1 Determination of formaldehyde release climate ChamberOverview

      • Specifications
      • Comments
      • FAQs
      XD-1JQ-F1
      Determination of formaldehyde release climate Chamber

      Overview

        The environmental chamber can realistically simulate environmental parameters such as temperature, humidity, ventilation frequency, and air flow rate on the surface of the pattern. Through the analysis and verification of the test data results, the amount of volatile toxic and harmful (VOC) substances contained in the pattern material can be measured and calculated. The impact of its release characteristics on the environment can in turn:

      ØDetermine the impact of environmental variables on the VOC release amount and release characteristics of test materials

      ØClassify materials according to their VOC release characteristics

      ØDevelopment of sample materials and verification of indoor air VOC release pollution characteristics

      ØThe VOC release amount of the sample

      ØAssessment of indoor air quality will be predicted based on detection data analysis

      fulfill the standard

      GB18580-2017 "Limits of Formaldehyde Release in Interior Decoration Materials - Artificial Panels and Their Products"

      GB18584-2001 "Limits of Hazardous Substances in Wood Furniture, Interior Decoration Materials" (Draft for Approval)

      Appendix A (Normative Appendix) in GB18587-2001 "Indoor Decoration Materials - Carpets, Carpet Pads and Carpet Adhesives - Release Limits of Hazardous Substances": Small Environmental Test Chamber Method.

      GB/T 31107-2014 "General Technical Conditions for Climate Chambers for Detection of Volatile Organic Compounds in Furniture"

      LY/T1980-2011 "Volatile organic compounds and formaldehyde release detection box"

      LY/T1981-2011 "Formaldehyde Release Gas Analysis Detection Box"

      ASTM D 6007-02 "Standard Test Method for Determination of Formaldehyde Concentration in Gas Released from Wood Products in a Small Environmental Chamber"

      EN 717-1 2004 "Wooden-based panels - Test determination of formaldehyde release - Part 1: Determination of formaldehyde release using a Test Chamber"

      ISO 12460-1.2007 "Determination of Formaldehyde Emission from Boards by 1m3 Climate Chamber Method" American Standard

      ISO 16000-9-2006 "Determination of volatile organic compounds released from building products and furniture - Laboratory release method"

      Related test reports

      Background test report

      Background test report

      Temperature and humidity measurement test report

      Temperature and humidity measurement test report

      Product details


      VS

      Moderner XD-1JQ-F1 Determination of formaldehyde release climate ChamberSpecifications

      LIST VALUE
      Temperature range 20~35℃
      Humidity control range 40~60% R.H.
      Temperature Fluctuation ±1℃
      Temperature Uniformity ≤2℃
      Temperature deviation ≤±2.0℃
      Humidity stability -2%RH,﹢3%RH
      Humidity Deviation ≤±3.0%RH
      wind speed The wind speed at the geometric center point in the box is 0.1~ 0.5m/s. (Wind speed is adjustable)
      noise Less than or equal to 55 decibels (A sound level), there will be no resonance sound between the box door and the equipment door
      Background concentration ≤0.006mg/m3
      Interior size 内箱Size1±0.02 m3;W960mm*H1050mm*D1000 mm
      Temperature Resolution 0.1℃
      Humidity resolution 0.1%RH
      air exchange rate 0.5~ 2 times/hour (adjustable); Flow rate adjustment range should be greater than 0.25~ 2.5m3/h;
      Flow rate Accuracy Digital Flow rate meter, Accuracy 0.5; 0~500L/min Glass rotor Flow rate meter, Accuracy not less than 2.5; 0.25~ 2.5m3/h
      Flow rate display Standard Glass Rotor Flow rate meter scale display (Flow rate range adjustable) _ Analog digital micro Gas flow rate meter, Touch screen Online Flow rate display (Flow rate range adjustable)
      Air tightness When the pressure is over 1000pa, the leakage is less than 10-3 × 1m3/min; the gas flow rate difference between the import and export of the gas is less than 1%; the air pressure monitoring in the box, analog digital display micro pressure Sensors, touch screen online pressure display in the box
      Stabilization time Temperature Stabilization time is less than 40min; Humidity Stabilization time is less than 70min, the equipment can run continuously for not less than 30 days;

      Moderner XD-1JQ-F1 Determination of formaldehyde release climate Chamber Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +Moderner XD-1JQ-F1 Determination of formaldehyde release climate Chamber Big data
        +Moderner XD-1JQ-F1 Determination of formaldehyde release climate ChamberKnowledge
        +Moderner XD-1JQ-F1 Determination of formaldehyde release climate ChamberStandard
        +Navigation
        Moderner
        MODERNER XD-1JQ-F1 1m3 formaldehyde release determination Climate Chamber, top matching type
        Service
        Focus on online sales of Lab Testing Instruments