MODERNER XD-1JQ-A1-P 1m3 formaldehyde release determination climate chamber, rapid desorption type
The MODERNER XD-1JQ-A1-P formaldehyde release determination Climate Chamber can classify the material according to the VOC release characteristics of the pattern material. The temperature control range of XD-1JQ-A1-P is + 20 ℃~ + 35 ℃, and it can be sprayed for rapid desorption.
Moderner-
HUANGYI HYQ-1000L 1 cubic meter formaldehyde release environment Test Chamber
Login -
Ring instrument HYV-60-4 VOC equilibrating chamber 4 barrel type
Login -
HYQC-1500 1.5 cubic meters environment Test Chamber Glass
Login -
HYV-1000 1 cubic meter VOC emission environment Test Chamber
Login -
Ring instrument HYV-60-6 VOC equilibrating chamber 6 barrel type
Login
Overview
The environmental chamber can realistically simulate environmental parameters such as temperature, humidity, ventilation frequency, and air flow rate on the surface of the pattern. Through the analysis and verification of the test data results, the amount of volatile toxic and harmful (VOC) substances contained in the pattern material can be measured and calculated. The impact of its release characteristics on the environment can in turn:
Determine the impact of environmental variables on the VOC release amount and release characteristics of test materials
Classify materials based on their VOC release characteristics
Research and development of sample materials and verification of indoor air VOC release pollution characteristics
The time duration attenuation of the VOC release amount of the sample
The assessment of indoor air quality will be predicted based on the detection data analysis.
fulfill the standard
GB18580-2017 "Limits of Formaldehyde Release in Interior Decoration Materials - Artificial Panels and Their Products"
GB18584-2001 "Limits of Hazardous Substances in Wood Furniture, Interior Decoration Materials" (Draft for Approval)
Appendix A (Normative Appendix) in GB18587-2001 "Indoor Decoration Materials - Carpets, Carpet Pads and Carpet Adhesives - Release Limits of Hazardous Substances": Small Environmental Test Chamber Method.
GB/T 31107-2014 "General Technical Conditions for Climate Chambers for Detection of Volatile Organic Compounds in Furniture"
LY/T1980-2011 "Volatile organic compounds and formaldehyde release detection box"
LY/T1981-2011 "Formaldehyde Release Gas Analysis Detection Box"
ASTM D 6007-02 "Standard Test Method for Determination of Formaldehyde Concentration in Gas Released from Wood Products in a Small Environmental Chamber"
EN 717-1 2004 "Wooden-based panels - Test determination of formaldehyde release - Part 1: Determination of formaldehyde release using a Test Chamber"
ISO 12460-1.2007 "Determination of Formaldehyde Emission from Boards by 1m3 Climate Chamber Method" American Standard
ISO 16000-9-2006 "Determination of volatile organic compounds released from building products and furniture - Laboratory release method"
Related test reports

Background test report

Temperature and humidity measurement test report
Product details


Moderner XD-1JQ-A1-P Determination of formaldehyde release climate ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | 20~35℃ |
| Humidity control range | 40~60% R.H. |
| Temperature Fluctuation | ±1℃ |
| Temperature Uniformity | ≤2℃ |
| Temperature deviation | ≤±2.0℃ |
| Humidity stability | -2%RH,﹢3%RH |
| Humidity Deviation | ≤±3.0%RH |
| wind speed | The wind speed at the geometric center point in the box is 0.1~ 0.5m/s. (Wind speed is adjustable) |
| noise | Less than or equal to 55 decibels (A sound level), there will be no resonance sound between the box door and the equipment door |
| Background concentration | ≤0.006mg/m3 |
| Applicable standards | GB18580-2017、GB18584-2001、GB18587-2001、GB/T17657-2013、LY/T 1981-2011、JG/T 344-2011、ASTMD 6007-02、EN 717-1 2004、GB 50325-2010、ISO 12460-1.2007 |
| Interior size | 内箱Size1±0.02 m3;W960mm*H1050mm*D1000 mm |
| air exchange rate | 0.5~ 2 times/hour (adjustable); Flow rate adjustment range should be greater than 0.25~ 2.5m3/h |
| Flow rate Accuracy | Glass Rotor Flow rate meter, Accuracy not less than 2.5; 0.25~ 2.5m3/h |
| Flow rate display | Standard Glass Rotor Flow rate meter scale display (Flow rate range adjustable), the analog digital Micro Gas flow rate meter, Touch screen Online Flow rate display (Flow rate range adjustable) |
| Air tightness | When the pressure is over 1000pa, the leakage is less than 10-3 × 1m3/min; the gas flow rate difference between the import and export of the gas is less than 1%; the air pressure monitoring in the box, analog digital display micro pressure Sensors, touch screen online pressure display in the box |
| Stabilization time | Temperature Stabilization time is less than 40min; Humidity Stabilization time is less than 70min, the equipment can run continuously for not less than 30 days; |
| desorption | Sprinkable rapid desorption |
Moderner XD-1JQ-A1-P Determination of formaldehyde release climate Chamber Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJG/T 527-2017
- ActiveSN/T 3026-2011
- ActiveLY/T 1982-2011
- ActiveLY/T 1981-2011
- ActiveLY/T 1612-2004
- ActiveGB/T 39600-2021
- ActiveGB/T 43353-2023
- ActiveGB/T 33043-2016


XD-1JQ-A1-P