ANGNI AD400C Slap Aseptic Homogenizer
ANGNI AD400C Aseptic Homogenizer bag size 170 × 300 mm, Processing capacity 30~400 ml.
AN-
LYD500W-T LABOratory High Shear Dispersion Homogenizer 24G/80-5000ml
$ 958.00 -
Lanyu LYD500W-T LABOratory High Shear Dispersion Homogenizer 30G/100-8000ml
$ 1017.00 -
Lanyu 18G Homogenizer can be equipped with optional dispersion head
$ 378.00 -
Lanyu LYD500W-T LABOratory High Shear Dispersion Homogenizer 36G/150-13000ml
$ 1075.00 -
Huxi FJ200-SH Digital Display Constant Speed High Speed Dispersion Homogenizer Φ12/18mm
$ 576.00
Introduction
AD400C LABOratory Aseptic Homogenizer, also known as Slap Homogenizer.
It is suitable for the homogenization of animal tissues and biological samples in the fields of food, medicine, cosmetics, clinical, molecular, toxin and bacterial detection, etc., to separate or extract microorganisms contained in the interior and surface of solid samples, and to obtain representative samples. .
The instrument is composed of an operation control manager, a stainless steel homogenization preparation box and a sterile homogenization bag, etc. It has the characteristics of simple experimental operation, digital screen display control, homogenization and softness, no pollution, no damage, no heating, no sterilization treatment, no need to wash utensils, effectively prevent cross-contamination, and protect the safety of operators, etc. Accurate results, good repeatability and other experimental requirements.

AN AD400C Slap Sterile HomogenizerSpecifications
| LIST | VALUE |
|---|---|
| Rated Voltage | AC220V |
| Rated Frequency | 50/60 Hz |
| Input Power | 180W |
| Operating Mode | S1 (continuous) |
| slapping speed | 3~ 12 times/second |
| tap spacing | 0~40mm |
| Run Settings | 3 sets of given values |
| Allowable Relative Humidity | ≤80% |
| Homogeneous bag size | 17×30cm |
| Processing Capacity | 30~400 ml |
| Dimensions | 380*220*33mm |
| Machine Weight | 22.0 kg |
AN AD400C Slap Sterile Homogenizer Packing list
Homogenizer x1, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- HANNA HI96821 Digital refractometer operation guide
- Classification and Application of Formula Guide
- Lab Film Applicators for prepative polypropylene (PP) nitrile films
- Selection guide for Surface Tensiometers
- Critical surface tension and its role in pigment wettability
- Demonstration of RCA wear-resistant tape machine
- Difference Between Halogen Moisture Analyzer and Thermogravimeter
- Calibration Terms - Coating Thickness Gages
- Application and test method of UV accelerated weathering Test Chamber in automotive Glass film
- The performance of lithium button batteries needs to be tested


AD400C





