EASTONG ETA-068NF Coating Thickness Gauge measurement of nonmagnetic metal substrates such as copper, aluminum, zinc, tin, etc. Thickness of nonconductive coatings
EASTONG ETA-068NF Coating Thickness Gauge eddy Current, Measurement range 0~1000μm, error range +/- 3%, resolution 0.1μm | 1μm, Display screen LCD.
Eastong-
LANDTEK CM8822 platings Thickness Gauge measurement of nonconductive coatings on magnetically permeable objects and nonconductive coatings on nonmagnetic metal substrates
$ 332.00 -
LANDTEK Thickness Gauge probe 90 ° right angle iron based probe
$ 161.00 -
LINSHANG LS216 Multilayer Ultrasonic Thickness Gauge Simultaneous measurement of multilayer thickness, suitable for various substrates
$ 1081.00 -
LANDTEK CM8825Fn platings Thickness Measurement Instrument Dual function coating Thickness Measurement Instrument
$ 386.00 -
LEEB Leeb231 eddy Current Coating Thickness Gauge Measurement range 0~1250μm
$ 332.00
Introduction
ETA-068NF Split Eddy Current Coating Thickness Gauge adopts the eddy current thickness measurement method, which can non-destructively measure the thickness of non-conductive covering layers on non-magnetic metal substrates such as copper, aluminum, zinc, tin, etc., such as enamel, rubber, paint, plastic, etc. ETA-083NF surface coating Thickness Gauge has the characteristics of small measurement error, high reliability, good stability, easy operation, etc., is a testing instrument required to control and ensure product quality, and is widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields.
Parameters
| Model | ETA-068NF |
| Operating Principle | Eddy current |
| Measuring range | 0~1000um |
| Measurement accuracy | ±(3%H±1.5) |
| Display accuracy | 0~99.9um: 0.1um/100um or more: 1um |
| Statistical function (single measurement) | Average, maximum, minimum, number of measurements |
| Minimal matrix | 10*10 mm |
| Minimum curvature | Convex 5mm, concave 25mm |
| Thinnest matrix | 0.5mm |
| Ambient temperature | 0℃~40℃ |
| Relative Humidity | Not more than 85% |
| power supply | 2 No. 7 batteries |
| Fuselage size | 125mm×74mm×33mm |
Features
Small design, easy to carry
Fully intelligent design, easy to operate
The measurement is fast and repeatable
Zero-point calibration, two-point calibration
LCD digital display
Metric/Imperial unit conversion
There is a beep prompt during operation
Two probe designs for different testing sites
ETA-068NF Coating Thickness GaugeIt has an automatic shutdown function
Iron-based and non-iron-based materials are automatically recognized
Eastong ETA-068NF Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 0~1000μm |
| margin of error | ±3% |
| Resolution | 0.1μm|1μm |
| Minimum measurement surface | 10*10mm |
| Minimum radius of curvature | Convex 5mm; Concave 25mm |
| thinnest substrate | 0.5mm |
| probe | NF split probe |
| statistical function | Measurement Times, MAX Maximum, MIN Minimum, Average |
| icon function | without |
| Power Supply | 2 * AAA Battery |
| Calibrated Certificate | without |
| system language | Chinese |
| Display screen | LCD screen |
| supporting software | without |
| Machine size | 125*74*33mm |
| Operating temperature | 0~40℃ |
| Relative Humidity | ≤85%RH |
Eastong ETA-068NF Coating Thickness Gauge Packing list
host x1, standard piece x3, base x1, battery x2, cleaning cloth x1, manual x1, warranty card x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Introduction of nondestructive thickness testing principle and instrument
- Influencing factors of ultrasonic thickness indication distortion
- Application Value of Coating Thickness Gauge in Steel Structure Coating Construction
- How to choose a Thickness Gauge?
- National testing standards commonly used in car painting
- Measuring methods of coating Thickness Gauge
- Principle, Application and Type Selection Analysis of Chrome Coating Thickness Gauge
- Film defect analysis and solution summary
- Introduction of calibrating method of metal coating Thickness Gauge
- How to choose a suitable painting Thickness Gauge?