JINGQI FP6410 Flame photometer
Dual channel, potassium, sodium concentration direct reading, menu keyboard operation, correlation coefficient automatic calculation, can be equipped with printer, computer, flame size pre-selected, with flameout protection device
JingQi-
YUEFENG FP6423 Flame photometer Calcium Ca/Ba
$ 1450.00 -
JINGHUA 7600S Dual beam of light UV-Visible Spectrophotometer Wavelength Accuracy +/- 0.3nm
$ 5083.00 -
JINGHUA H300 Dual beam of light Spectrophotometer Wavelength range 190nm-1100nm
$ 2656.00 -
YueFeng 722S Single beam of light Visible Spectrophotometer
$ 334.00 -
YueFeng 723N Visible Spectrophotometer Wavelength 325~ 1100nm
$ 832.00
Features
·Double channel
· Potassium, sodium concentration direct reading
· Menu keyboard operation
· Automatic calculation of correlation coefficient
·Can be equipped with a printer
·Can be connected to computer
·The flame size is pre-selected
·With flameout protection device

Application
·ceramics
·cement
·Glass
· Soil fertilizer
·Medical clinic
·Refractories
·Third party testing
·Professional colleges
JingQi FP6410 Flame photoMeterSpecifications
| LIST | VALUE |
|---|---|
| Operating Mode | Interference filter |
| display | LED LCD |
| Sample absorption and spray Volume | <6mL/min |
| Stability | ≤ 3% within 15s; ≤ 5% within 5min |
| Response time | <8S |
| Detection limit | K:≤0.004mmol/L;Na:≤0.008mmol/L |
| Sexual repeability | ≤ 3% |
| linearity error | K:≤0.005mmol/L ;Na:≤0.03mmol/L |
| test range | K: 0 ~ 100ug / ml; Na: 0 ~ 160ug / ml |
| Filter light transmission characteristics | Potassium: Absolute value of peak wavelength error ≤ 7nm Sodium: Absolute value of peak wavelength error ≤ 5nm |
| Filter light transmission characteristics | Potassium: half width ≤ 15nm Sodium: half width ≤ 15nm |
| Filter light transmission characteristics | Potassium: Background transmittance ≤ 0.5% Sodium: Background transmittance ≤ 0.5% |
JingQi FP6410 Flame photoMeter Packing list
host x1, power cord x1, instruction manual x1, certificate x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 713.2-2023
- ActiveASTM D4185-23
- ActiveGB/T 3260.1-2024
- ActiveGB/T 693-2024
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 38216.5-2024
- ActiveGB/T 42513.7-2024
- ActiveGB/T 6730.89-2024
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveYS/T 514.7-2009
- ActiveQX/T 216-2013
- Active 01010102-2006
- ActiveGB/T 15262-1994
- ActiveGB/T 15516-1995
- ActiveGB/T 16129-1995


FP6410