JINGQI WD9203B Portable Water Quality Tester (COD/Total Nitrogen)
Jingqi WD9203B portable water quality Tester Measurement range COD: 0~2000mg/L Total nitrogen: 0.05~ 100mg/L, COD error of indication ≤ +/- 5%, total nitrogen error of indication ≤ +/- 5% and 0.2 The largest, Repeatability ≤ 3%, anti-chlorine interference ≤ 2000mg/L (COD determination)
JingQi-
JINGQI WD8105 Cyanide Tester
$ 481.00 -
HANNA HI981420 Water Quality Tester
$ 654.00 -
TONGAO TR 6900N Benchtop Total Nitrogen STIP-scan
$ 2807.00 -
TONGAO TR-116H Manganese meter, water quality heavy metals Detector
$ 786.00 -
HANNA HI97748 Manganese/potassiumhy permanganate [LR] Portable Photometer
$ 540.00
Features
1. The digestion instrument is separated from the measuring instrument, which does not affect the measurement accuracy. Temperature PID automatic temperature control and timing.
2. High-performance ultra-low-power 16-bit microcontroller, the standby time of the instrument can reach more than 6 months.
3. Time-saving operation.
4. Cold light source, narrow-band interference optical system, good optical stability.
5. Data power-off protection function.
6. 30 standard curves and 199 measured values (including measured values, absorbance values and transmittance with time labels year, month, day, hour, minute, second) can be saved.
7. With USB port, it can be connected to a computer for recording and reading or printing out the stored data.
8. The main chassis is made of molded ABS material, IP65 design, and has good waterproof and dustproof performance.

JingQi WD9203B Portable water quality TesterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | COD: 0~2000mg/L Total nitrogen: 0.05~ 100mg/L |
| An indication of COD error | ≤±5 % |
| TN error of indication | ≤ +/- 5% and the largest of 0.2 |
| Repeatability | ≤3% |
| anti-chlorine interference | ≤2000mg/L(COD) |
| Optical inspection Stability | <0.002A/20min |
| Dimension | Host 80 * 230 * 55mm Digestion instrument 105 * 160 * 90mm |
JingQi WD9203B Portable water quality Tester Packing list
Host x1, Digester x1, instruction manual x1, certificate x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1012-2019
- ActiveHG/T 5669-2019
- ActiveSL/T 788.2-2019
- ActiveGB/T 42955-2023
- ActiveGB/T 29599-2013
- ActiveHJ 2515-2012


WD9203B





![HANNA HI97748 Manganese/potassiumhy permanganate [LR] Portable Photometer](http://img.nbchao.com/imgs/200/2024/03/29/1402320004222739.jpg)