HYV-1000 1 cubic meter VOC emission environment Test Chamber
Ring instrument VOC emission environment Test Chamber HYV-1000 is a Test Chamber volume of 1000L 1 cubic meter VOC emission environment Test Chamber, HYV-1000 Temperature range is 20~100 ℃, Temperature fluctuation is 0.5 ℃, stainless steel cabin.
huangyi-
HYV-1000 1 cubic meter VOC emission environment Test Chamber
Login -
HUANGYI HYQ-1000L 1 cubic meter formaldehyde release environment Test Chamber
Login -
Ring instrument HYV-60-6 VOC equilibrating chamber 6 barrel type
Login -
HYQC-1500 1.5 cubic meters environment Test Chamber Glass
Login -
Ring instrument HYV-60-4 VOC equilibrating chamber 4 barrel type
Login
Introduction
The VOC emission Test Chamber HYV-1000 is an instrument and equipment used to simulate the release of VOC (formaldehyde) by products in an environment close to people's living. It is used to test and evaluate furniture, building materials, automotive interiors and other products. The amount of harmful substances released.
This Test Chamber provides a clean closed space (very low background concentration), no liquid water (to prevent formaldehyde and other components to be measured that are easily absorbed by water), and at the same time control the temperature, humidity, wind speed, relative pressure, and temperature in the chamber. The gas rate is used to simulate the pollutant release process of the product in an environment similar to that of people living, and the release amount is determined by monitoring the concentration of pollutants in the warehouse, which is used to evaluate the environmental protection level of the product.
Applications
It is mainly used to detect the release of formaldehyde and VOC in interior decoration materials, decoration materials, wood-based panels, and its wood products; at the same time, it can also test the release of VOC in other products. Comprehensive environmental index evaluation of indoor air quality based on indoor pollutant data or prediction models.
Features
1) The professional air jacket indirect temperature control method is adopted, which has the characteristics of large contact area, small heat transfer temperature difference, uniform heat exchange, stable temperature, and no condensed water.
2) Humidity control adopts dry and wet air ratio mixing method, microcomputer PID adjustment, fast response speed, high control precision, humidity balance is about half an hour, far faster than dew point method, shortening the experiment cycle.
3) The moisture adopts the company's unique low-temperature evaporation technology, no resistance, no temperature difference, soft humidification and no condensation.
4) Low background concentration design, sealing materials and air replacement pipelines and other components are all made of clean materials that do not release VOC (stainless steel, copper, polytetrafluoroethylene, etc.).
5) Energy-saving design, generally using frequency converter and silicon controlled rectifier to adjust the load to achieve lower operating power.
6) Fresh air purification: The air supply after multiple treatments of precision filter, permeable membrane, polar adsorbent, and non-polar adsorbent is very clean, which can isolate external pollution.
7) Microcomputer intelligent control, automatic temperature control, automatic humidity control, automatic water replenishment, automatic alarm, automatic recording, one-button switch, whole-process monitoring.
8) Air supply components, air circulation components, filter components, and humidification components are all built in the control cabinet, which occupies less space, has low noise, and is simple and beautiful.
system protection
①High temperature protection in the cabin
②Power overload, leakage, phase loss, underVoltage, overVoltage, phase sequence protection
③ Refrigeration system high-low pressure protection, overload protection
④Heating component overheating protection
⑤ Anti-load impact design
⑥Motor overcurrent protection
⑦ fan, air pump overheating, overload protection
⑧Humidification and water shortage protection
⑨Pressure protection
plan

huangyi HYV-1000 1 cubic Meter VOC emission environment Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Interior Volume | 1000L±20L |
| Interior size | 850*1080*1100mm |
| Dimensions | 1580×1285×1572mm |
| Door (door opening) (width × height) | 850×1100mm |
| Observation window (width × height) | 225×365mm |
| Temperature range | 20~100 ℃ (high temperature cleaning temperature 250 ℃) |
| Temperature fluctuation | 0.5 ℃ |
| Adjustment Accuracy | ± 1.0 ℃ when complying with VDA276 standard |
| Temperature Uniformity | ≤±0.8 ℃ |
| Measurement Accuracy | ±0.1℃ |
| Temperature control method | Air jacket indirect temperature control method (external heating and cooling components) |
| Humidity control range | 20~80% R.H. (20-30 ℃) When conforming to VDA276 standard, 5% R.H. (65 ℃) |
| Humidity fluctuation | ≤ ± 1% RH |
| Humidity Uniformity | ≤ ± 2% RH |
| Adjustment Accuracy | ±3%R.H. |
| Measurement Accuracy | ±2.5%R.H. |
| Humidity control method | Dry and moisture proportional control method (external), stable time ≤ 40 min |
| Background concentration | Formaldehyde ≤ 0.006 mg/m3 |
| Single VOC background | ≤0.002 mg/m3 |
| TVOC background value | ≤0.02 mg/m3 |
| Air exchange rate | 0.2~ 2.5 times/hour |
| Center wind speed | 0.1~ 1.0 m/s Compliant with VDA276 standard, wind speed greater than 1.0m/s |
| Adjustment Accuracy | Ventilating Volume ± 3% |
| Measurement Accuracy | ±0.01m³/h |
| tightness | Add 1000Pa overpressure, the gas leakage is less than 1 × 10-3m3/min |
| Equipment collection rate | >85 % |
| Relative positive pressure retention | 10±5 Pa |
| compressed air | Air Volume: 1.2m ³/h; working pressure: greater than 2bar |
| dryer | Maximum air Volume 1.2m ³/h |
| Cabin material | SUS304 mirror stainless steel 1.5mm, rounded corners, full welding and polishing |
| Enclosure Material | Q235A Cold rolled steel plate 1.5mm, surface electrostatic spraying, white |
| sealing material | Imported PTFE, fluororubber |
| Thermal insulation material | 80 mm, high density polyurethane foam |
| Efficient particulate filtrator handles maximum air Volume | 2m³/h |
| Particulate concentration in gas treated by high efficiency particulate filtrator | Microparticles with a diameter greater than 0.5um Concentration < 100particles/m ³ |
| Activated carbon filtrator handles maximum air Volume | 2m³/h |
| Particulate concentration in gas treated by activated carbon filtrator | TVOC concentration < 20ug/m ³; microparticle number concentration greater than 0.5um diameter < 100particles/m ³; O3 < 10ug/m ³, NOx and SOx < 10ug/m ³ |
| Human Machine Interface | Delta 7-inch color touch screen (provides Ethernet port, can be controlled remotely) |
| Equipment control method | The following control methods can be realized: ① Local control: operate the device directly on the touch screen; ② Regional control: view and control the device on any local area network computer; ③ Remote control: access the control device anywhere through the Internet |
| Automatically record items | ① Temperature; ② Humidity; ③ Pressure; ④ Flow; ⑤ Running time ⑥ System alarm; can realize system control, program setting, dynamic Data Display and historical data playback, fault record, alarm setting and other functions |
| Data Interface | The device provides the following external interfaces: ① USB A: 1 ② USB B: 1 ③ RJ-45:1 ④ RS232:1 |
| Sampling interface | 3 ( ∈ 8mm ) |
| Noise | ≤60 dB |
| cover an area | 1.7 × 2.8 m (width × depth, including door opening and surrounding heat dissipation space) |
| Power | AC380V 3KW |
| Humidification water | Distillation water |
| Replenishment cycle | > 20 days (continuous operation) |
huangyi HYV-1000 1 cubic Meter VOC emission environment Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveISO 12460
- ActiveJJG 1172-2007
- ActiveHG/T 5173-2017
- ActiveJG/T 481-2015
- ActiveJG/T 527-2017
- ActiveSN/T 3026-2011
- ActiveLY/T 1982-2011
- ActiveLY/T 1981-2011
- ActiveLY/T 1612-2004
- ActiveGB/T 43353-2023
- ActiveGB/T 33043-2016
- ActiveGB/T 38597-2020
- ActiveISO 3251-2019
- ActiveGB/T 23984-2009
- ActiveASTM D 3960-2018
- ActiveGB/T 23985-2009