Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Formaldehyde Climatic Chamber> huangyi> huangyi HYV-1000 1 cubic Meter VOC emission environment Test Chamber

      HYV-1000 1 cubic meter VOC emission environment Test Chamber

      Ring instrument VOC emission environment Test Chamber HYV-1000 is a Test Chamber volume of 1000L 1 cubic meter VOC emission environment Test Chamber, HYV-1000 Temperature range is 20~100 ℃, Temperature fluctuation is 0.5 ℃, stainless steel cabin.

      Brand
      SKU: NB024244
      China huangyi
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • huangyi HYV-1000 1 cubic Meter VOC emission environment Test ChamberOverview

        • Specifications
        • Comments
        • FAQs
        HYV-1000
        1 cubic Meter VOC emission environment Test Chamber

        Introduction

        The VOC emission Test Chamber HYV-1000 is an instrument and equipment used to simulate the release of VOC (formaldehyde) by products in an environment close to people's living. It is used to test and evaluate furniture, building materials, automotive interiors and other products. The amount of harmful substances released.

        This Test Chamber provides a clean closed space (very low background concentration), no liquid water (to prevent formaldehyde and other components to be measured that are easily absorbed by water), and at the same time control the temperature, humidity, wind speed, relative pressure, and temperature in the chamber. The gas rate is used to simulate the pollutant release process of the product in an environment similar to that of people living, and the release amount is determined by monitoring the concentration of pollutants in the warehouse, which is used to evaluate the environmental protection level of the product.

        Applications

        It is mainly used to detect the release of formaldehyde and VOC in interior decoration materials, decoration materials, wood-based panels, and its wood products; at the same time, it can also test the release of VOC in other products. Comprehensive environmental index evaluation of indoor air quality based on indoor pollutant data or prediction models.

        Features


        1) The professional air jacket indirect temperature control method is adopted, which has the characteristics of large contact area, small heat transfer temperature difference, uniform heat exchange, stable temperature, and no condensed water.

        2) Humidity control adopts dry and wet air ratio mixing method, microcomputer PID adjustment, fast response speed, high control precision, humidity balance is about half an hour, far faster than dew point method, shortening the experiment cycle.

        3) The moisture adopts the company's unique low-temperature evaporation technology, no resistance, no temperature difference, soft humidification and no condensation.

        4) Low background concentration design, sealing materials and air replacement pipelines and other components are all made of clean materials that do not release VOC (stainless steel, copper, polytetrafluoroethylene, etc.).

        5) Energy-saving design, generally using frequency converter and silicon controlled rectifier to adjust the load to achieve lower operating power.

        6) Fresh air purification: The air supply after multiple treatments of precision filter, permeable membrane, polar adsorbent, and non-polar adsorbent is very clean, which can isolate external pollution.

        7) Microcomputer intelligent control, automatic temperature control, automatic humidity control, automatic water replenishment, automatic alarm, automatic recording, one-button switch, whole-process monitoring.

        8) Air supply components, air circulation components, filter components, and humidification components are all built in the control cabinet, which occupies less space, has low noise, and is simple and beautiful.

        system protection

        ①High temperature protection in the cabin

        ②Power overload, leakage, phase loss, underVoltage, overVoltage, phase sequence protection

        ③ Refrigeration system high-low pressure protection, overload protection

        ④Heating component overheating protection

        ⑤ Anti-load impact design

        ⑥Motor overcurrent protection

        ⑦ fan, air pump overheating, overload protection

        ⑧Humidification and water shortage protection

        ⑨Pressure protection

        plan

        Display of VOC emission environmental Test Chamber HYV-1000 of Huanyi Instrument

        VS

        huangyi HYV-1000 1 cubic Meter VOC emission environment Test ChamberSpecifications

        LIST VALUE
        Interior Volume 1000L±20L
        Interior size 850*1080*1100mm
        Dimensions 1580×1285×1572mm
        Door (door opening) (width × height) 850×1100mm
        Observation window (width × height) 225×365mm
        Temperature range 20~100 ℃ (high temperature cleaning temperature 250 ℃)
        Temperature fluctuation 0.5 ℃
        Adjustment Accuracy ± 1.0 ℃ when complying with VDA276 standard
        Temperature Uniformity ≤±0.8 ℃
        Measurement Accuracy ±0.1℃
        Temperature control method Air jacket indirect temperature control method (external heating and cooling components)
        Humidity control range 20~80% R.H. (20-30 ℃) When conforming to VDA276 standard, 5% R.H. (65 ℃)
        Humidity fluctuation ≤ ± 1% RH
        Humidity Uniformity ≤ ± 2% RH
        Adjustment Accuracy ±3%R.H.
        Measurement Accuracy ±2.5%R.H.
        Humidity control method Dry and moisture proportional control method (external), stable time ≤ 40 min
        Background concentration Formaldehyde ≤ 0.006 mg/m3
        Single VOC background ≤0.002 mg/m3
        TVOC background value ≤0.02 mg/m3
        Air exchange rate 0.2~ 2.5 times/hour
        Center wind speed 0.1~ 1.0 m/s Compliant with VDA276 standard, wind speed greater than 1.0m/s
        Adjustment Accuracy Ventilating Volume ± 3%
        Measurement Accuracy ±0.01m³/h
        tightness Add 1000Pa overpressure, the gas leakage is less than 1 × 10-3m3/min
        Equipment collection rate >85 %
        Relative positive pressure retention 10±5 Pa
        compressed air Air Volume: 1.2m ³/h; working pressure: greater than 2bar
        dryer Maximum air Volume 1.2m ³/h
        Cabin material SUS304 mirror stainless steel 1.5mm, rounded corners, full welding and polishing
        Enclosure Material Q235A Cold rolled steel plate 1.5mm, surface electrostatic spraying, white
        sealing material Imported PTFE, fluororubber
        Thermal insulation material 80 mm, high density polyurethane foam
        Efficient particulate filtrator handles maximum air Volume 2m³/h
        Particulate concentration in gas treated by high efficiency particulate filtrator Microparticles with a diameter greater than 0.5um Concentration < 100particles/m ³
        Activated carbon filtrator handles maximum air Volume 2m³/h
        Particulate concentration in gas treated by activated carbon filtrator TVOC concentration < 20ug/m ³; microparticle number concentration greater than 0.5um diameter < 100particles/m ³; O3 < 10ug/m ³, NOx and SOx < 10ug/m ³
        Human Machine Interface Delta 7-inch color touch screen (provides Ethernet port, can be controlled remotely)
        Equipment control method The following control methods can be realized: ① Local control: operate the device directly on the touch screen; ② Regional control: view and control the device on any local area network computer; ③ Remote control: access the control device anywhere through the Internet
        Automatically record items ① Temperature; ② Humidity; ③ Pressure; ④ Flow; ⑤ Running time ⑥ System alarm; can realize system control, program setting, dynamic Data Display and historical data playback, fault record, alarm setting and other functions
        Data Interface The device provides the following external interfaces: ① USB A: 1 ② USB B: 1 ③ RJ-45:1 ④ RS232:1
        Sampling interface 3 ( ∈ 8mm )
        Noise ≤60 dB
        cover an area 1.7 × 2.8 m (width × depth, including door opening and surrounding heat dissipation space)
        Power AC380V    3KW
        Humidification water Distillation water
        Replenishment cycle > 20 days (continuous operation)

        huangyi HYV-1000 1 cubic Meter VOC emission environment Test Chamber Packing list

        complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        HYV-1000 environmental test chamber, can you test the ammonia release? Want to use to detect ammonia release in concrete test block Gas Analyzer in the test chamber can detect specific gases
        [A]
        A small amount is OK. If a large amount is corrosive, it will not work. The specifics need to be further confirmed. Contact our technology to recommend your selection.
        [Q]
        Can HYV-1000 test ammonia release?
        [A]
        Ammonia is corrosive. If the quantity is large, it cannot be used with PuNeng 304 material.
        [Q]
        Meet GB/T239851 cubic meters VOC emission environment test chamber
        [A]
        HYV-10001 cubic meters VOC emission environment test chamber, please refer to
        huangyi
        HYV-1000 1 cubic meter VOC emission environment Test Chamber