JFL Qxp 0-50 ISO Grindometer single-channe 0~50μm
The JFL ISO Grindometer Qxp 0-50 is a single-channe Fineness Gauge with a range of 0 to 50 microns and a recommended range of 15 to 40 μm. The Qxp 0-50 Grindometer is used to test the impurity particle fineness of pigments in Paints and paint pulps.
JFL-
TRUIT TR 1201/015 single-channe Coating Fineness gauge 0~15μm
$ 165.00 -
TQCVF2124 double-channel fineness grindometer 0-500µm
$ 1524.00 -
TQCsheen VF2142 wide-channel Fineness gauge Range 0~5000μm
$ 1698.00 -
Pushen 0-15um single-channe small Fineness gauge (single-channe) detects the Fineness of Coatings, inks and other particles
$ 192.00 -
TRUIT TR 1202/015 double-channel Fineness ruler 0~15μm
$ 187.00
Introduction
Jinfulun Qxp scraper Fineness Meter is manufactured in accordance with the relevant regulations of international standards ISO1524 and GB/T 1724-2019. It is used to measure the particle fineness of paint and related products. The scraper fineness is divided into single groove and double groove. .
Product Usage
The ink fineness plate is used to determine the fineness of pigments and impurities in paints and paint slurries.
Range selection
When the fineness is below 30um, an ink fineness plate with a measuring range of 50um should be used; when the fineness is above 30um, an ink fineness plate with a measuring range of 100um or 150um should be used.
plan

JFL QXP 0-50 GrindometerSpecifications
| LIST | VALUE |
|---|---|
| range | 0~50μm |
| Graduation | 5µm |
| Scraper type | Single-channe |
| Number of grooves | 1 |
| Scale unit | μm |
| Scraper size | 175mm*65 mm*13mm |
| Groove size | 140*12.5mm |
| Drawdown blade size | 90*40*6mm |
| scraper material | stainless steel |
| Drawdown blade material | stainless steel |
| Applicable standards | ISO1524、GB/T 1724-2019 |
| Calibrated Certificate | without |
| Recommended range | 15~40μm |
JFL QXP 0-50 Grindometer Packing list
Fineness Gauge X1, manual X1, certificate X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the gloss meters that meet the GB/T9966 standard?
- What are the models of stone gloss meter? What is the difference?
- These gloss meters can be used in paper inspection, understand!
- How to choose the right model for Jinfulun JFL gloss meter?
- Jinfulun JFL-B60 Glossiness Meter instruction manual
- Study on uncertainty analysis of Moisture meter measurement results by drying method
- ActiveJT/T 821.3-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveGB/T 1724-2019
- ActiveASTM D1316-2020
- ActiveGB/T 5211.17-1988
- ActiveJJG 905-2010
- ActiveASTM D333-2021
- ActiveISO 1524-2020
- AbolishGB/T 13217.3-2008
- ReplacedQB/T 2025-1994
- ActiveGB/T 21867.2-2008
- ActiveQB/T 1046-2012
- ReplacedASTM D1210-1996
- ReplacedISO 1524-2000
- ActiveHG/T 2243-1991
- ActiveGB/T 13492-1992
- ActiveGB/T 6745-2008
- ActiveGB/T 17459-1998


QXP 0-50