NIRUN NTV-T1HA Viscosity and temperature control machine 100-6.6 mPa · s
Measurement range 100~6.6mPa · s, Rotor specification SC4-21, 27, 28, 29, Rotor speed 0.3~ 100rpm, reproducibility +/- 0.5% F.S, Measurement accuracy +/- 1% F.S, Power supply Voltage input AC100-240V, 50Hz/60Hz. Output DC17V1.2A, Interface RS232, USB, Operating language Chinese, capacity 2~ 16ml.
NiRun-
FANGRUI LV-SSR-H Viscometer Coaxial Cylinder Structure, Small Sample Adapter
$ 1470.00 -
Pingxuan RVTV-2H Brinell Viscometer High Temperature Viscometer 10 million mpas
$ 2092.00 -
NIRUN NTV-E1 Intelligent Touch Digital Viscometer Measurement range 1-10 million Pa.s
$ 1313.00 -
NIRUN DV-79 Digital Viscometer with Printer 1 million mPa · s
$ 1059.00 -
YUEPING NDJ-8S Rotational Viscometer is used in grease, paints, plastics, accessories, Coatings, detergents, etc
$ 610.00
Introduction
Viscosity temperature control all-in-one machine is a combination of viscosity measurement and precise temperature control. It breaks through the split machine composed of constant temperature Water Tank, viscosity measuring instrument and small sample adapter in the existing market.
The all-in-one viscosity measurement system is composed of a 7-inch wide touch screen host, a small sample adapter (SSR), a cylindrical sample sleeve, an SC4 rotor, and a temperature controller;
Only 2 to 16m of sample is required for testing, and the cylindrical geometry of the SC4 rotor provides very accurate viscosity measurements.
Electric control lift, precise positioning. The small sample cylinder is easy to load and unload, which brings convenience to the cleaning work.
The small-volume sample cylinder is closely connected with the temperature controller, so that the temperature of the sample can be kept very accurately. The stirring action of the rotor, coupled with the small amount of sample, can minimize the inhomogeneity of the sample temperature and greatly shorten the constant temperature time;
The viscosity measurement system comes with a password protection temperature and viscosity correction coefficient, allowing users to correct the temperature and viscosity correction coefficient by themselves on the premise of reliable and accurate data;
Support infinitely variable speed measurement of viscosity, input any speed, it will directly reflect the full scale of each rotor, which is convenient for users to select test conditions;
Support external U disk data storage; single-point, continuous, and timing three storage methods are optional.
plan

NiRun NTV-T1HA Viscosity temperature control machineSpecifications
| LIST | VALUE |
|---|---|
| Display | touch type |
| Measuring range | 100~6.6mPa·s |
| Rotor Specifications | SC4-21, 27, 28, 29 |
| Rotor speed | 0.3~100rpm |
| Reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1% |
| Power | Input AC100-240V, 50Hz/60Hz. Output DC17V1.2A. |
| Data Interface | RS232、USB |
| Operating language | Chinese |
| Capacity | 2~16ml |
| Lifting system | Automatic lifting system |
| Temperature range | -1~150℃ |
| temperature Accuracy | ±0.1℃ |
| software system | SNB data collection and plotting software (optional) |
| Speed control method | CVT |
NiRun NTV-T1HA Viscosity temperature control machine Packing list
host x1, rotor x4, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle characteristics and application analysis of spot inks viscosity Measurement Instrument
- Nirun Ultra Low Viscosity Adapter ULA Instructions for Use
- Difference and comparison of three series of NDJ/SNB/DV rotary viscometer
- How does the Rotational Viscometer meet the needs of constant temperature of experimental samples?
- How to measure unknown viscosity samples
- Operation steps and precautions for the use of Nirun viscometer
- ActiveSH/T 0732-2004
- ActiveDIN EN 12092-2002
- AbolishGB/T 14235.8-1993
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveJJG 1002-2005
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ReplacedHG/T 3323-1982
- ActiveSY/T 0522-2008
- ActiveGB/T 21882-2008
- ActiveSY/T 5377-2007
- ActiveSY/T 0520-2008
- ActiveGB/T 5561-2012
- ActiveJB/T 9357-1999
- ActiveGB/T 10247-2008


NTV-T1HA
NTV-T1L