KYLINBELL GL-1600 Dry Thermostat
KYLINBELL GL-1600 Dry Thermostat Temperature range RT+ + 5~ 100 ℃, Temperature change time ≤ 15min (20 ℃ to 100 ℃), Maximum setting time 99h59min, Maximum Power 150W.
kylinbell-
Jinan HORIZON F-35 Backpressure High Temperature Cooking Instrument
$ 2920.00 -
Leakage marking Tester (touch screen) pure platinum electrode purchased separately
$ 1794.00 -
TQC VF2200 Moisture Penetration Cup SH1003 10cm2
$ 504.00 -
Jinan HORIZON ZPY-01 axis deviation Tester 100-200mm
$ 1075.00 -
CIMA ST9660A + PCBA Circuit Board Thermal Analyzer
$ 992.00
Application
It is suitable for the constant temperature of trace samples in life science, bioengineering, microbiology and medical clinical experiments; The conventional instrument for incubation, boiling, denaturation and concentration analysis has high constant temperature accuracy, no constant temperature dead angle, and uniform temperature, which completely overcomes the shortcomings of uneven temperature and large temperature fluctuation of Water Bath constant temperature.

Features
Ultra-compact design. It does not occupy limited space, compact and convenient. The whole machine is integrated with touch key control, and the set temperature and real-time temperature display are clean and beautiful. The rectangular aluminum alloy heating seat can be quickly replaced. Heating seats with different aperture diameters can be configured at will.
GL-1600 Dry Thermostat Optional Module
| Model | description | Maximum temperature |
| C1 | 96 x 0.2 ml centrifuge tubes | Φ104.5mm x 32 |
| C2 | 59 x 0.5ml centrifuge tubes | Φ104.5mm x 32 |
| C3 | 39 x 1.5ml centrifuge tubes | Φ104.5mm x 32 |
| C4 | 39 x 2.0 ml centrifuge tubes | Φ104.5mm x 32 |
| C5 | 18 x 5.0 ml centrifuge tubes | Φ104.5mm x 32 |
| C6 | 24×0.5 ml + 30×1.5 ml centrifuge tubes | Φ104.5mm x 32 |
| C7 | 58×6mm | Φ104.5mm x 32 |
| C8 | Customized modules | |
Instrument general configuration For example, GL-1600C1 means that the instrument model GL-1600 is selected, and the C1 model module is equipped. | ||
kylinbell GL-1600 Dry ThermostatSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | Room temperature + 5~ 100 ℃ |
| Temperature change time | ≤ 15min (20 ℃ to 100 ℃) |
| Maximum setup time | 99h59min |
| Maximum Power | 150W |
kylinbell GL-1600 Dry Thermostat Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


GL-1600





