QIWEI BNT-4T Portable Coated-4 Viscometer Pure Copper/4mm
Outflow time 0~150s, flow hole diameter 4mm, capacity 100ml, cup body material pure copper, Applicable standard GB/T 1723, correction coefficient K = 1 +/- 0.03.
-
LND-3 Coating Viscometer 4mm Copper Coating Viscosity Flow Cup
$ 119.00 -
YONGLIDA QNB-3 No. Outflow Viscosity Cup 3mm aperture Measurement range 7~ 14cSt
$ 141.00 -
TRUIT TR 1004/2.5 French standard Viscosity Cup aperture φ2.5mm
$ 125.00 -
TRUIT TR 1002/5 Ford Viscosity Cup outflow aperture φ5.20mm
$ 125.00 -
TRUIT TR 1002/4 Ford Viscosity Cup outflow aperture φ4.12mm
$ 125.00
Principles and calculations
The viscosity measured by the COAT-4 viscometer is the conditional viscosity, that is, the time for a certain amount of sample to flow out of the hole with a specified pore size at a certain temperature, expressed in seconds. The resulting specimen elution time (s) is converted into kinematic viscosity values (mm²/s) using the following formula:
At t<23s, t=0.154μ+11
At 23s≤t≤150s, t=0.223μ+6.0
where:
t— outflow time, s;
μ – kinematic viscosity, mm²/s.
Main technical characteristics:
1. The Tu-4 viscometer is made of brass, with a capacity of about 100 ml, and its geometric size and inner wall roughness conform to the provisions of GB/T 1723 Coating Viscosity Determination Method, and its bottom is an outflow hole of stainless steel.
2. Correction coefficient K: multiply the viscosity measured by the corrected viscometer by the K value, which is the conditional viscosity measured by the viscometer. The correction factor K should be in the range of 1±0.03, otherwise the viscometer should be replaced. The viscometer should be calibrated regularly according to the frequency of its use.
3. The difference between the measured value and the calculated value of the standard viscosity liquid with known kinematic viscosity from the Tu-4 viscometer should be within ±3% of the calculated value.
QiWei BNT-4T Tu -4 ViscometerSpecifications
| LIST | VALUE |
|---|---|
| outflow time | 0~150s |
| flow hole diameter | 4mm |
| Capacity | 100ml |
| Cup body material | pure copper |
| Applicable standard | GB/T 1723 |
| Correction factor | K=1±0.03 |
QiWei BNT-4T Tu -4 Viscometer Packing list
Viscosity cup × 1, certificate ×, manual × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJB/T 3078-2015
- ActiveQB/T 5477-2020
- ActiveJT/T 821.4-2011
- ActiveJT/T 821.3-2011
- ActiveJT/T 821.2-2011
- ActiveJJG 743-2018
- ActiveHG/T 3830-2006
- AbolishGB/T 13217.4-2008
- ActiveQB/T 1046-2012
- ActiveGB/T 1723-1993
- ActiveJC/T 423-1991
- ActiveGB/T 4653-1984
- ActiveHG/T 2661-1995
- ActiveHG/T 2005-1991
- ActiveJB/T 4297-2008
- ActiveJB/T 6886-2010
- ActiveJB/T 6504-1992
- ActiveGB/T 1979-1979
- ReplacedJJG 743-1991
- AbolishGB/T 13217.4-2008


QiWei
BNT-4T
TND-4G