SANFA GRX-140 Hot Air Sterilization Oven (Dry Heat Sterilizer) 140L
SANFA GRX-140 hot air detoxification box (dry heat disinfection box) Temperature range RT + 10~300 ℃, volume 140L, GRX dry heat disinfection box uses high temperature dry heat to cause microbial oxidation, protein denaturation, dielectric condensation poisoning and other effects.
sanfa-
Kenton DHG-9230C Precision digital display thermostatic drying oven 230L
$ 770.00 -
YIHENG BPZ-6123B Electronic semiconductor Vacuum Oven with imported Vacuumpump
$ 4098.00 -
BOZHEN 766-3A Far infrared Drying Oven
$ 380.00 -
SANFA DHG-9960A vertical Forced Air Drying Oven 960L
$ 3204.00 -
BOZHEN DGG-9240A Vertical Forced Air Drying Oven 225L/200 ℃
$ 781.00
GRX dry heat disinfection box uses high temperature and dry heat to oxidize microorganisms, denature proteins, and cause poisoning caused by dielectric concentration. Among them, the protoplasm of cells is mainly destroyed by oxidation, and microorganisms are killed, so all microorganisms can be killed within a certain heating time.
Features
※Accurate: High-precision microcomputer LCD display temperature controller, accurate and reliable temperature control, with over-temperature, sensor failure, leakage, alarm functions, and timing function.
※Rapid: Fast heating, forced convection, dry hot air directly passing the heated object, drying and disinfection time is significantly shortened.
※Safety: There is an independent temperature limit alarm system, which will be automatically interrupted when the limit is exceeded to ensure the safety of personnel and instruments.
※Convenience: Mirror stainless steel liner, rounded corners, easy to clean, and the shelf can be moved easily. It can be equipped with RS-485 interface, which can be connected to a printer and a computer, and can record the changes of temperature parameters.
Series selection
| model | GRX-30 | GRX-70 | GRX-140 | GRX-240 |
| Voltage | ~220V 50Hz | |||
| volume | 35L | 70L | 140L | 220L |
| Temperature control range | RT+10-300℃ | |||
| temperature resolution | 0.1°C | |||
| temperature fluctuation | ±1℃ | |||
| temperature uniformity | ±2°C (test point is 100°C) | |||
| power | 320W | 470W | 620W | 770W |
| studio size | 300×300×350 | 350×400×480 | 450×500×580 | 500×550×780 |
| Dimensions | 562×490×520 | 612×670×650 | 712×770×750 | 762×810×950 |
| Timer Range | 1-9999min | |||
sanfa GRX-140 Hot air detoxification boxSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | RT+10~300℃ |
| Temperature Fluctuation | ±1℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Uniformity | ±2℃ |
| Volume | 140L |
| Interior size | 450*500*580mm |
| Chamber material | Mirror stainless steel |
| Timer | 1~9999min |
| Power | 220V 50Hz |
| Input Power | 620W |
| Environmental temperature | RT+5~40℃ |
| Dimensions | 712*770*750mm |
| Communication interface | RS-485 interface (optional) |
sanfa GRX-140 Hot air detoxification box Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 17782-1999
- ActiveQB/T 5250-2018
- ActiveJB/T 5520-1991
- ActiveGB/T 11026.5-2010
- ActiveGB/T 21782.7-2008
- AbolishGB/T 16592-1996


GRX-140
GRX-30
GRX-70
GRX-240





