SANFA GRX-240 Hot Air Sterilization Oven (Dry Heat Sterilizer) 240L
SANFA GRX-240 hot air detoxification box (dry heat disinfection box) Temperature range RT + 10~300 ℃, volume 220L, GRX dry heat disinfection box uses high temperature dry heat to cause microbial oxidation, protein denaturation, dielectric condensation poisoning and other effects.
sanfa-
HUITAI HTG-9070A Vertical Blast Drying Oven volume 80L water analysis/BOD determination
$ 512.00 -
Kenton 101-4A digital Forced Air Drying Oven 640L with independent temperature limiter
$ 736.00 -
BOZHEN DHG-9140A Desktop Forced Air Drying Oven
$ 604.00 -
BENTING CBX230BE Hot Air Disinfection Box, LCD 230L
Login -
SANFA DHG-9960A vertical Forced Air Drying Oven 960L
$ 3180.00
GRX dry heat disinfection box uses high temperature and dry heat to oxidize microorganisms, denature proteins, and cause poisoning caused by dielectric concentration. Among them, the protoplasm of cells is mainly destroyed by oxidation, and microorganisms are killed, so all microorganisms can be killed within a certain heating time.
Features
※Accurate: High-precision microcomputer LCD display temperature controller, accurate and reliable temperature control, with over-temperature, sensor failure, leakage, alarm functions, and timing function.
※Rapid: Fast heating, forced convection, dry hot air directly passing the heated object, drying and disinfection time is significantly shortened.
※Safety: There is an independent temperature limit alarm system, which will be automatically interrupted when the limit is exceeded to ensure the safety of personnel and instruments.
※Convenience: Mirror stainless steel liner, rounded corners, easy to clean, and the shelf can be moved easily. It can be equipped with RS-485 interface, which can be connected to a printer and a computer, and can record the changes of temperature parameters.
Series selection
| model | GRX-30 | GRX-70 | GRX-140 | GRX-240 |
| Voltage | ~220V 50Hz | |||
| volume | 35L | 70L | 140L | 220L |
| Temperature control range | RT+10-300℃ | |||
| temperature resolution | 0.1°C | |||
| temperature fluctuation | ±1℃ | |||
| temperature uniformity | ±2°C (test point is 100°C) | |||
| power | 320W | 470W | 620W | 770W |
| studio size | 300×300×350 | 350×400×480 | 450×500×580 | 500×550×780 |
| Dimensions | 562×490×520 | 612×670×650 | 712×770×750 | 762×810×950 |
| Timer Range | 1-9999min | |||
sanfa GRX-240 Hot air detoxification boxSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | RT+10~300℃ |
| Temperature Fluctuation | ±1℃ |
| Temperature Resolution | 0.1℃ |
| Temperature Uniformity | ±2℃ |
| Volume | 220L |
| Interior size | 500*550*780mm |
| Chamber material | Mirror stainless steel |
| Timer | 1~9999min |
| Power | 220V 50Hz |
| Input Power | 770W |
| Environmental temperature | RT+5~40℃ |
| Dimensions | 762*810*950mm |
| Communication interface | RS-485 interface (optional) |
sanfa GRX-240 Hot air detoxification box Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 17782-1999
- ActiveQB/T 5250-2018
- ActiveJB/T 5520-1991
- ActiveGB/T 11026.5-2010
- ActiveGB/T 21782.7-2008
- AbolishGB/T 16592-1996


GRX-240
GRX-30
GRX-70
GRX-140





