Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Gas detector> HuiRuiPu> HuiRuiPu HRP-T1000-EX Combustible Gas Detector (no display, no light)

      HUIRUIPU HRP-T1000-EX Combustible Gas Detector (No Display No Light)

      Catalytic Sensors principle, detection of gas EX, diffusion sampling, two-stage concentration alarm, flameproof design, suitable for hazardous conditions 1 and 2 zones, the range is 0~100% LEL.

      Brand
      SKU: NB026364
      China HuiRuiPu
      Stock
      Loading…
      Price
      $ 117.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HuiRuiPu HRP-T1000-EX Combustible Gas Detector (no display, no light)Overview

        • Specifications
        • Comments
        • FAQs
        HRP-T1000-EX
        Combustible Gas Detector (no display, no light)
        • HUIRUIPU HRP-T1000-EX Combustible Gas Detector (No Display No Light)
        • HUIRUIPU HRP-T1000-EX Combustible Gas Detector (No Display No Light) Figure 1
        Catalytic Sensors principle, detection of gas EX, diffusion sampling, two-stage concentration alarm, flameproof design, suitable for hazardous conditions 1 and 2 zones, the range is 0~100% LEL.

        Introduction

        HRP-T1000 Gas Detector is used in flammable and explosive gas leakage places and chemical plant areas where poisonous and harmful exists. The instrument adopts catalytic combustion sensor and electrochemical sensor technology imported from the United States. The product has the advantages of stable signal and high precision. The instrument shell is made of The explosion-proof and explosion-proof design of cast aluminum is one-time forming, and the wiring method is suitable for various dangerous places.

        The instrument is widely used in pharmaceuticals, chemical fertilizers, natural gas pipeline networks, sewage treatment, municipal administration, iron and steel smelting, chlorine plants, acetylene plants, refrigeration workshops, chemical workshops, gas station areas, boiler rooms, hotel kitchen operating rooms, etc. that require anti-virus and fire protection Explosion-proof places.

        Features

        ◆The detection accuracy and measuring range are adjustable

        ◆Long life, high sensitivity, low drift, stable and reliable work

        ◆Two-level concentration alarm, with relay output function

        ◆With temperature compensation, automatic zero point correction function

        ◆4~20mA standard analog output and RS485 digital output, can be uploaded to DCS, PLC system

        ◆Infrared remote control mode, the Detector can be adjusted without opening the cover, which is safe and convenient

        ◆Explosion-proof design is suitable for hazardous conditions in zones 1 and 2


        Detection principle : The system provides 24V standard DC Voltage to the external transmitter, collects
                             the input signal of the standard 4-20mA transmitter, analyzes and processes it to complete the digital display and alarm operation.

        Applicable objects : This system supports the input signals of various standard transmitters. Such as gas transmitters: carbon monoxide, hydrogen sulfide,

        Gas alarm controller use and Application

        It can be used in oil exploration, oil and gas transportation, oil refining, metallurgy, power plants, chemicals, oil depots, liquefied gas stations, mines, tunnels, tunnels, underground pipelines and other places that require fire protection, explosion protection, and poisoning for gas safety detection and alarm.


        VS

        HuiRuiPu HRP-T1000-EX Combustible Gas Detector (no display, no light)Specifications

        LIST VALUE
        Sensors principle Catalytic
        Detection gas EX
        Sampling method diffusion
        Debugging method Infrared remote control
        Ambient Temperature -20~+50℃
        Relative Humidity <95%
        Explosion-proof method flameproof
        Explosion-proof sign Ex dⅡC T6 Gb
        Power DC24V±15%
        Output signal Current: (4~ 20) mA
        switching quantity 1 (the first-level alarm point is always open)
        power consumption ≤3W
        Connection Cable ≥1.5mm2×3;≥1.5mm2×4
        Maximum distance between Detector and host ≤1000m
        Machine Weight ≤1500g
        Operating Pressure 86~106kPa
        Dimensions 190*150*95mm
        range 0~100%LEL

        HuiRuiPu HRP-T1000-EX Combustible Gas Detector (no display, no light) Packing list

        Complete machine X1, operation manual X1, certificate of conformity X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Does this combustible gas detector comply with the GB15322.1 standard?
        [A]
        The combustible gas detector is suitable for GB15322.1. Please consult customer service for detailed application definition.
        [Q]
        HRP-T1000-EX Combustible Gas Detector (No Display No Light) Sensors principle is catalytic?
        [A]
        Yes, Gas detector uses catalytic detection principle. Detect gas EX
        HuiRuiPu
        HUIRUIPU HRP-T1000-EX Combustible Gas Detector (No Display No Light)
        Service
        Focus on online sales of Lab Testing Instruments