Linshang LS192 Glossiness Meter 60 °/1000GU
60 ° angle; range 0~1000GU; no button, real-time measurement; with QC detection function; through the Measurement Institute detection; with software
LinShang-
KSJ MG68-F2 intelligent Gloss meter, projection angle 60 °/85 °
Login -
Gloss Measurement Instrument JFL-BZ20 (high light smart) JFL 20 degree surface high gloss measurement
$ 389.00 -
3NH YG60 Single Angle Glossiness Meter
$ 285.00 -
QILI MN75 paper Glossmeter paper Glossmeter
$ 487.00 -
KSJ MG6-SA Microporous Gloss Meter, range 0~999GU polished mirror measurement
Login
Introduction
LS192 is a hand-held gloss meter with a 60° universal angle design and a range of up to 1000GU. It is widely used on the surface of paint, coating, ink, plastic, paper, ceramic tile, ceramic, stone, metal and electroplating products. Gloss test. The instrument is easy to operate, and it can be tested immediately after release, without key operation. In addition to the normal mode, it can also be set to the QC mode, which can realize QC rapid detection. The instrument is also equipped with powerful PC software, which can be used for online measurement, intelligent statistics of data and generation of measurement reports.
Features
1. The operation is simple, it can be used immediately after being turned on, the instrument can be released and measured immediately, and the data can be locked with one key, without cumbersome settings.
2. The instrument can be switched to normal mode or QC mode to adapt to different application scenarios. The normal mode is ready to release and measure, and the reading is fast; the QC mode can customize the upper and lower limit values and judge whether the data is qualified or not, which can realize the rapid detection of incoming materials.
3. The instrument has the function of ambient temperature compensation, the value is stable, and it allows long-term calibration. The repeatability is very good, within the measurement range of 0-100GU, the repeatability can reach ±0.2GU; within the measurement range of 100-1000GU, the repeatability can reach ±0.2% of reading
4. The LS192 gloss meter can ensure that it passes the test of any metrology institute, conforms to the national JJG696-2002 standard for first-class working machines, and can completely compare with the test data of imported gloss meters.
5. Equipped with dedicated upper computer software (only supports Windows system), supports PC-side setting, online measurement, and can print test reports for test results.
6. Strong magnetic bottom cover design, two-in-one with the standard plate, can be calibrated after power-on, no need to worry about losing the calibration plate.
7. Built-in high-performance rechargeable lithium battery, the instrument has ultra-low power consumption, and can be used continuously for more than 48 hours after one charge.
8. Slim body, compact and portable, aviation aluminum shell, industrial style design, super good texture.
The product meets the standard
LS192 gloss meter complies with the following standards: ISO2813, ISO7668, ASTM D523, ASTM D2457, DIN 67530, GB/T9754, GB/T13891, GB/T7706, GB/T8807. To the requirements of the first-level working machine in the measurement verification regulations of "gloss meter and gloss board".
software download
Connect to the computer via USB, you can use the gloss meter PC software. (PC software only supports Windows operating system) This software can perform functions such as online measurement, parameter setting, report generation and printing.
It can be installed by:
1) In the product packaging box, the attached U disk is equipped with PC software, no need to install, just run it directly.
2) Download the software online to the local, and run it directly after decompression
Precautions
The recommended calibration cycle is one year, and the company provides calibration services.
When the battery of the instrument is empty, it should be charged in time.
If the instrument is not used for more than half a year, it needs to be charged regularly to prevent the battery from being damaged due to excessive discharge.
If there are multiple instruments, it is necessary to put the instruments into the base corresponding to the serial number for calibration.
The instrument has temperature compensation, which allows long-term calibration, and it is recommended to calibrate once a week. If the ambient temperature changes significantly, recalibration is required.
The test port of the instrument should be attached to the surface of the measured object to prevent external light from leaking in.
After the base is removed from the main unit, it should be stored in a clean place to avoid contamination of the standard board.
Do not insert any objects into the instrument to clean it, as this will damage the instrument and affect measurement accuracy and operational safety.
The instrument and standard plate should be cleaned before storage and use, and the pollutants should be removed with a clean special lens cloth. The surface of the standard plate is very precise, make sure that the lens cloth does not have any fine particles, otherwise it will damage the standard plate.
LinShang LS192 Glossiness meterSpecifications
| LIST | VALUE |
|---|---|
| Geometry | 60° |
| Measuring Areas | 9*15mm |
| Minimum size of test object | 20mm*10mm |
| Measurement range | 0~1000GU |
| Division Value | 0.1GU |
| Sexual repeability | 0-100GU: ± 0.2GU; 100-1000GU: ± 0.2% reading |
| Reproducibility | 0-100GU: ± 0.5GU; 100-1000GU: ± 0.5% reading |
| Zero Error | 0.1GU |
| Error of indication | 0-100GU: ± 1.5GU; 100-1000GU: ± 1.5% reading |
| Weight | Approx. 300g |
| Power | Rechargeable lithium battery 3.7V@1000mAh |
| Display | 192 × 64 lattice |
| Language | Simplified Chinese, English |
| Charging port | USB(Type-C) |
| Data Interface | USB |
| Environment Operating Temperature | 10~45 ℃, 0~85% RH (no condensation) |
| Storage temperature | -10~60 ℃, 0~85% RH (no condensation) |
| Encasement list | Glossiness meter, USB data cable, software U disk, cleaning cloth, manual, Certificate/quality assurance card |
LinShang LS192 Glossiness meter Packing list
Glossiness meter x1, base x1 with standard board, USB data cable x1, charger x1, special lens cleaning cloth x1, user manual x1, product certificate x1, warranty card x1, lens paper x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- LS192 Gloss Meter Quick Use Guide and Operation Video
- Linshang LS192 Gloss Meter Beauty Picture Appreciation
- ActiveGB/T 13217.2-2024
- ActiveSY/T 4106-2016
- Active 002-2017
- ActiveFZ/T 01097-2006
- AbolishGB/T 11420-1989
- ActiveGB/T 13448-2019
- ActiveHG/T 2006-2006
- ActiveHG/T 5370-2018
- ActiveHG/T 5183-2017
- ActiveHG/T 5180-2017
- ActiveASTM D3794-2022
- ActiveJJG 696-2015
- AbolishASTM F1843-2015
- ActiveASTM D1455-2023
- ActiveASTM D3928-2018
- ActiveGB/T 1766-2008
- ActiveHG/T 4758-2014
- ActiveHG/T 4761-2014
- ActiveGB/T 23999-2009
- ActiveGB/T 20503-2006


LS192