HUIRUIPU HRP-T1000-O2 Oxygen Gas Detector (LCD without lamp)
Sensors principle of HUIRUIPU HRP-T1000-O2 oxygen Gas Detector electrochemistry, detection of gas O2, sampling method natural diffusion, Display mode LCD liquid crystal display concentration value, status indication 3 LED lights indicate power supply, secondary alarm, debugging infrared remote control.
HuiRuiPu-
GUOYUGRA GY/VGD-200-NF3-G (0-50ppm) Nitrogen trifluoride Detector
$ 817.00 -
HONEYEAGLE HNAG1000-NH3 Fixed Ammonia Gas Detector 0-200PPM
$ 436.00 -
SMART SENSOR AS8801 Oxygen Detector
$ 149.00 -
HONEYEAGLE HNAG1000-NH3 Fixed Ammonia Gas Detector 0-15000PPM
$ 856.00 -
GUOYUGRA GY/VGD-200-C2HCL3-G (0-50ppm) trichloroethylene Detector
$ 419.00
Introduction
HRP-T1000 Gas Detector is used in flammable and explosive gas leakage sites and chemical plant areas where toxic and harmful substances exist. The instrument uses catalytic combustion sensors and electrochemical sensor technology imported from the United States. The product has the advantages of stable signal and high accuracy. The instrument casing is made of The one-time cast aluminum molding is explosion-proof and explosion-proof design, and the wiring method is suitable for various dangerous places.
Instruments are widely used in pharmaceuticals, chemical fertilizers, natural gas pipeline networks, sewage treatment, municipal administration, iron and steel smelting, chlorine plants, acetylene plants, refrigeration workshops, chemical workshops, gas station areas, boiler rooms, hotel kitchen operating rooms, etc. that require poison and fire prevention Explosion-proof place.
Features
âDetection accuracy and measuring range are adjustable
âLong life, high sensitivity, low drift, stable and reliable operation
âTwo-level concentration alarm, with relay output function
âLCD display and working status display
âWith temperature compensation and automatic zero point correction functions
â4ï½20mA standard analog output and RS485 digital output, can be uploaded to DCS and PLC systems
âInfrared remote control allows you to adjust the Detector without opening the cover, which is safe and convenient
âThe explosion-proof design is suitable for hazardous conditions zones 1 and 2.
Detection principle : The system provides 24V standard DC Voltage to the external transmitter, collects
the input signal of the standard 4-20mA transmitter, and analyzes and processes it to complete digital display and alarm operations.
Applicable objects : This system supports the input signals of various standard transmitters. Such as gas transmitter: carbon monoxide, hydrogen sulfide,
Gas alarm controller uses and application fields
Used for gas safety detection and alarm in oil exploration, oil and gas transportation, oil refining, metallurgy, power plants, chemical industry, oil depots, liquefied gas stations, mines, tunnels, tunnels, underground pipelines and other places that require fire protection, explosion protection and poisoning prevention.
HuiRuiPu HRP-T1000-O2 Oxygen Gas Detector (No Lights, LCD Model)Specifications
| LIST | VALUE |
|---|---|
| Sensors principle | Electrochemistry |
| Detect gas | Oxygen O2 |
| Sampling method | Diffusion |
| Display | LCD liquid crystal display concentration value |
| status indication | 3 LED lights indicating Power , secondary alarm |
| debugging method | Infrared remote control |
| Ambient Temperature | -20~+50℃ |
| Relative Humidity | <95% |
| Explosion-proof method | flameproof type |
| Explosion-proof sign | Ex dⅡC T6 Gb |
| Power | DC24V±15% |
| Output signal | Current: (4~ 20) mA |
| switching quantity | 1 (the first-level alarm point is normally open) |
| power consumption | ≤3W |
| Connection Cable | ≥1.5mm2×3;≥1.5mm2×4 |
| The maximum distance between the Detector and the host | ≤1000m |
| Machine Weight | ≤1500g |
| Operating Pressure | 86~106kPa |
| Dimensions | 190*150*95mm |
| Range | 0~30%vol |
HuiRuiPu HRP-T1000-O2 Oxygen Gas Detector (No Lights, LCD Model) Packing list
whole machine X1, operation manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHJ 872-2017
- ActiveSN/T 5162-2019
- ActiveJB/T 11621-2013
- ActiveGB/T 20936.3-2017
- ActiveGB/T 20936.2-2017


HRP-T1000-O2