LANDTEK CM8823 film thickness eddy Current Coating Thickness Gauge
Eddy Current thickness measurement principle, split N-type probe, thickness measurement range 0~1000μm, error range +/- 3%, no supporting software, can be used for nonconductive coating testing on aluminum, with automatic shutdown function, can be customized Miscellaneous large range.
LANDTEK-
Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
$ 341.00 -
Defelsko Positector 6000 FJS1 magnetic Coating Thickness Gauge 25mm
$ 1509.00 -
CHINA CTG-800-3000F Coating Thickness Gauge, Integrated Iron-based Standard Type
$ 206.00 -
Defelsko PosiTector 6000 FHXS1 Coating Thickness Gauge, hot surface Coating Thickness Gauge
$ 1624.00 -
Defelsko PosiTector 6000 FN3 metal thickness Measurement Instrument
$ 1756.00
product description
The domestic (CN) LANDTEK CM8823 Film Thickness Gauge is a portable structure design, an eddy current coating Thickness Gauge with an external N-type probe, and the LCD displays the measured thickness data, which is simple and intuitive. The CM8823 coating Thickness Gauge uses the principle of eddy current thickness measurement. The Film Thickness Gauge is used to measure the thickness of the coating with a range of 0~1000 microns. The minimum measurable curved surface is 3mm convex, and the minimum measurement area is 6mm. Auto power off function saves energy and prolongs battery life.
Applications
| Specification model: | CM8823 |
| Applications: | Eddy current sensing Film Thickness Gauge CM-8823 uses eddy current sensors to measure enamel, rubber, paint, plastic layers, etc. on copper, aluminum, zinc, tin and other substrates. Widely used in manufacturing, metal processing, chemical industry, commodity inspection and other testing fields. |
Features
CM8823 Film Thickness Gauge adopts the principle of eddy current thickness measurement, which is suitable for measuring the thickness of non-conductive coating on aluminum substrate.
Pictures




Selection reference chart

LANDTEK Film Thickness Gauge Selection List

LANDTEK CM8823 Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | eddy current |
| Measuring range | 0 ~ 1000µm |
| margin of error | ±3% |
| resolution | 0.1mm | 1mm |
| Minimum radius of curvature | NF: convex 3mm; concave 50mm |
| thinnest matrix | 0.3mm |
| probe | NF Distribution Probe |
| icon function | without |
| Power | 4 * AA battery |
| Calibrated Certificate | without |
| Language | Chinese |
| Display screen | LCD |
| supporting software | without |
| Total Weight | 210G (without battery) |
| Complete-built unit size | 161*69*32mm |
| Minimum measurement surface | F6mm |
| Unit display | μm/mils |
| Voltage prompt | Low Voltage prompt |
| Operating Temperature | 0~40℃ |
| Optional accessories | Customizable Range (Large Range Sensors): 0~200um to 18000um |
| Relative Humidity | 10~90%RH |
LANDTEK CM8823 Coating Thickness Gauge Packing list
Host x1, probe (aluminum base) x1, reference block (aluminum base) CTG-BSx1, calibrated diaphragm CTG-CFx1, portable box x1, manual x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Appreciation of beautiful pictures taken by Lantai CM8823 Coating Thickness Gauge
- Lantai CM8820, CM8821, CM8822 and CM8823 Coating Thickness Gauge [Parameter comparison]
- CM-8822 Landtek Coating Thickness Gauge
- Comparison table of each model of LANDTEK Thickness Gauge [Selection Guide]
- ActiveISO
- ActiveGB/T 44757-2024
- ActiveJB/T 13939-2020
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveASTM D7091-2022
- ASTM E376-2019
- ActiveHG/T 3885-2006
- ActiveGB/T 13452.2-2008
- ActiveGB/T 11374-2012
- ActiveGB/T 4957-2003


CM8823