ZKHS GDJS-800D high-low temperature Humidity Cyclic Chamber -60~150 ℃/800L
Interior size 800 * 1000 * 1000mm, Temperature range -60~150 ℃, humidity control range 30~98% R.H, Temperature fluctuation ≤ ± 0.5 ℃, humidity deviation + 2, -3% R.H, heating rate -40 → 100 ℃ Technologies 45min, cooling rate 25~ -60 ℃ Technologies 65min
ZKHS-
ZKHS GDJS-010B High-low temperature Humidity Cyclic Chamber -20~150 ℃/1000L
$ 11948.00 -
HUDA vertical rapid temperature change Test Chamber QD-E708-512K60-X5
$ 13056.00 -
KESIONOTS high and low temperature experimental box KS-OTS-HD1000LC temperature control -40 ℃~ 150 ℃
$ 8186.00 -
ZKHS GDW-225D Temperature Cycling Test Chamber -60 ℃~ 150 ℃
$ 6320.00 -
BOZHEN GDW2025 low/high Temperature Test Chamber -20~130 ℃/250L
$ 4869.00
Product Description
◆This product is suitable for testing various performance indicators of aerospace products, information electronic instruments, materials, electrical engineering, electronic products, and various electronic components in high-low temperature or hot and humid environments.
Box structure
◆The box body is processed by CNC machine tools, with beautiful and elegant appearance, and adopts non-reactive handles, which are easy to operate.
◆The inner tank of the box is made of imported high-grade stainless steel (SUS304) mirror panel, and the outer shell of the box is made of A3 steel plate sprayed with plastic, which increases the appearance texture and cleanliness.
◆The water supply tank is placed in the lower right part of the control box, and has automatic protection against water shortage, which is more convenient for the operator to replenish water.
◆The large observation window is equipped with a lighting lamp to keep the inside of the box bright, and the built-in tempered glass in the heating element is used to clearly observe the situation inside the box at any time.
◆The pipeline of the humidification system is separated from the control circuit board, which can avoid failure due to water leakage of the humidification pipeline and improve safety.
◆Water system pipeline circuit system adopts door type opening, which is convenient for maintenance and repair.
◆Using ultra-fine glass fiber insulation cotton for thermal insulation of the cabinet, which can avoid unnecessary energy loss.
◆The test hole with a diameter of 50mm is equipped on the left side of the cabinet, which can be used for external test power lines or signal lines.
Programmable Logic Controller
◆The temperature and humidity control instrument adopts a (7.0-inch) super-large screen, which is easy to operate on the screen and easy to program edit. The controller operation interface is available in Chinese and English, and the real-time operation curve can be displayed on the screen.
◆It has the capacity of 100 groups of programs, 1000 segments and 999 cycle steps, and the maximum time setting for each segment is 99 hours and 59 minutes.
◆After the data and test conditions are input, the controller has a screen lock function to avoid stopping the machine due to human touch.
◆With RS-232 or RS-485 communication interface, it can design programs on the computer, monitor the test process and perform functions such as automatic power-off.
◆It has the function of automatic calculation, which can immediately correct the changing conditions of temperature and humidity, making the temperature and humidity control more accurate and stable.
Refrigeration and air circulation system
◆Refrigerator adopts French original "Taikang" fully enclosed compressor.
◆The refrigeration system adopts unit or binary low temperature loop system design.
◆Multi-blade air blower is used for strong air circulation, avoiding any dead angle, and can make the temperature and humidity distribution in the test area even.
◆The design of the wind circuit circulation air outlet and return air, the wind pressure and wind speed meet the test standards, and can make the temperature and humidity stabilize quickly when the door is opened. The heating, cooling, and humidification systems are completely independent and effective, reducing testing costs and increasing life. Reduce the failure rate.
Standards
Strictly refer to: GB/T10592-2008, GB/T10586-2006, GB/T2423.1-2008, GB/T2423.2-2008, GB/T2423.3-2006, GB/T2423.4-2008, GJB150.3A -2009, GJB150.4A-2009 and other related standards design and manufacture
Series selection
model | GDJS-100 | GDJS-225 | GDJS-500 | GDJS-800 | GDJS-010 |
Internal dimensions | 450X450X500mm | 500X600X750mm | 700X800X900mm | 800X1000X1000mm | 1000X1000X1000mm |
temperature range | A: 0℃~150℃ B: -20℃~150℃ C: -40℃~150℃ D: -60℃~150℃ E: -70℃~150℃ | ||||
humidity range | 30~98%RH | ||||
Fluctuation/Uniformity | ≤±0.5℃/≤+2℃ | ||||
Humidity Deviation | +2, -3%RH | ||||
Heating time | -20℃~100℃ for about 35min | -40℃~100℃about 45min | -70℃~100℃about 55min | ||
cooling time | 25℃~-40℃about 50min | 25℃~-60℃about 65min | 25℃~-70℃ for about 80min | ||
controller | (7.0 inches) large screen screen programmable touch temperature and humidity controller | ||||
Accuracy range | Setting accuracy: temperature ±0.1℃, humidity ±1%RH | ||||
Temperature and humidity sensor | Platinum resistance PT100Ω/MV | ||||
Heating system | Fully independent system, nickel-chromium alloy electric heating heater | ||||
humidification system | Built-in isolated, all stainless steel shallow surface evaporative humidifier | ||||
dehumidification system | Adopt evaporator coil dew point temperature laminar flow contact dehumidification method | ||||
Cooling System | Original French "Taikang", fully enclosed air-cooled compression refrigeration method | ||||
circulatory system | Temperature-resistant low-noise air-conditioning motor, multi-blade centrifugal wind wheel | ||||
Enclosure Material | A3 steel plate electrostatic spray treatment | ||||
Inner box material | SUS304 stainless steel good mirror plate | ||||
Insulation material | Polyurethane rigid foam, superfine glass fiber cotton | ||||
door frame insulation | Double-layer high-low temperature aging resistant silicone rubber door seal | ||||
Test time | 0~9999 M, H adjustable | ||||
Standard configuration | 1 set of multi-layer heating and defrosting glass window with lighting, 2 test sample racks, 1 test lead hole φ50mm | ||||
safety protection | Leakage, short circuit, over temperature, water shortage, motor overheating, compressor overpressure, overload, overcurrent protection | ||||
Voltage | AC220V±10% 50Hz AC380V±10% 50Hz Three-phase five-wire system | ||||
Ambient temperature | 5℃~+30℃ ≤85%RH | ||||
ZKHS GDJS-800D Temperature&Humidity Cycling Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Interior size | 800*1000*1000mm |
| Temperature range | -60~150℃ |
| Humidity control range | 30~98%R.H |
| Temperature fluctuation | ≤±0.5℃ |
| Humidity Deviation | +2、-3%R.H |
| Heating rate | -40→100℃≈45min |
| Cooling rate | 25~-60℃≈65min |
| display | (7.0 inch) large screen screen programmable touch temperature and humidity Controller |
| Accuracy range | Setting Accuracy: temperature ± 0.1 ℃, humidity ± 1% R.H |
| Temperature transducer | Platinum resistance PT100Ω/MV |
| Heating system | Fully independent system, nickel-chromium alloy electric heating heater |
| Humidification system | Built-in isolated, all stainless steel shallow surface evaporative humidifier |
| Dehumidification system | Adopt evaporator coil dewpoint temperature laminar flow contact dehumidification method |
| Refrigeration system | Original French "Taikang", fully enclosed air-cooled compression refrigeration method |
| Circulatory system | Temperature-resistant and low-noise air-conditioned motor, multi-leaf centrifugal wind turbine |
| Enclosure Material | A3 steel plate electrostatic spray treatment |
| Inner chamber material | SUS304 stainless steel high quality mirror steel plate |
| Thermal insulation material | Polyurethane Rigid Foam, Ultrafine Glass Fiber Cotton |
| Door frame insulation | Double Layer High and Low Temperature Conditioning Silicone Rubber Door Seal |
| Timer | 0~9999 M, H adjustable |
| Standard configuration | Multi-layer heating and defrosting with lighting Glass window 1 set, 2 test racks, 1 test lead hole φ50mm |
| Safety Devices | Leakage, short circuit, over temperature, water shortage, motor overheating, compressor overVoltage, overload, overcurrent protection |
| Power | AC220V ± 10% 50Hz AC380V? 10% 50Hz three-phase five-wire system |
| Environment temperature | 5~30℃ |
| Environment humidity | ≤85%R.H |
| Temperature Uniformity | ≤+2℃ |
ZKHS GDJS-800D Temperature&Humidity Cycling Test Chamber Packing list
Host x1, multi-layer heating and defrosting with lighting Glass window x1 set, test rack x2, test lead hole φ50mmx1, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 2424.7-2024
- ActiveQJ 481-1990
- Active 901-2021
- Active 10254-2022
- ActiveGB/T 9979-2005
- ActiveGB/T 39933-2021
- ActiveGB/T 10590-2006
- ActiveGB/T 33861-2017
- ActiveGB/T 10592-2023
- ActiveGB/T 32065.7-2015
- ActiveGB/T 2423.63-2019
- AbolishGB 15442.1-1995
- ActiveGB 28375-2012
- ActiveGB 12441-2018
- ActiveGB 14907-2018
- Active 10590-2006
- ActiveGB/T 2423.4-2008
- ActiveGB/T 41166-2021
- AbolishGB/T 2423.34-2005
- AbolishGB/T 2423.25-2008


GDJS-800D