ZKHS GDJW-010B High and Low Temperature Cyclic Test Chamber -20 ℃~ 150 ℃
Interior size 1000 * 1000 * 1000mm, Temperature range -20~150 ℃, Alternating range -20 ℃~ 85 ℃, Temperature fluctuation ≤ ± 0.5 ℃, Heating rate -20 → 100 ℃ Technologies 35min; -40 → 100 ℃ Technologies 45min, cooling rate 25~ -40 ℃ Technologies 50min; 25~ -60 ℃ Technologies 65min
ZKHS-
BENTING CBGDW-80L low/high Temperature Test Chamber -20 ℃/80L
Login -
ZKHS GDJS-500C high-low temperature Humidity Cyclic Chamber -40~150 ℃/500L
$ 10409.00 -
YIHENG BPHJ-060C experimental high-low temperature (alternating) Test Chamber -60 ℃~ 130 ℃/60L
$ 5967.00 -
HZAOC GDJW-010A high-low temperature cyclic Test Chamber -20-150 ℃/1000L
$ 10113.00 -
ZKHS GDJW-010C High and Low Temperature Cyclic Test Chamber -40 ℃~ 150 ℃
$ 11186.00
Applications
◆The product is suitable for aviation, aerospace products, information electronics, instrumentation, materials, electricians, electronic products, and various electronic components in the high-low temperature environment to test their performance indicators.
Cabinet structure
◆The box body is processed and formed by CNC machine tools, the shape is beautiful and generous, and the non-reaction handle is adopted, which is easy to operate.
◆ The inner tank of the box is made of imported stainless steel (SUS304) mirror panel, and the shell of the box is sprayed with A3 steel plate, which increases the appearance texture and cleanliness.
◆ The large observation window is equipped with a light to keep the box bright, and the tempered glass embedded in the heating body is used to clearly observe the situation in the box at any time.
◆The left side of the box is equipped with a test hole with a diameter of 50mm, which can be used for external test power cable or signal cable.
Control system
◆ The temperature control adopts "7.0" inch large-screen touch screen temperature and humidity control instrument, which is simple to operate and set.
◆After the data and test conditions are input, the controller has a locking function to avoid changing the temperature value by human touch.
◆ With the function of P.I.D automatic calculation, the temperature change conditions can be corrected immediately, so that the temperature control is more accurate and stable.
Refrigeration and air circulation system
◆ The refrigerator adopts the original French "Taikang" fully enclosed compressor unit.
◆ The refrigeration system is designed with unit or binary cryogenic circuit system.
◆ The multi-wing blower is used to supply air with strong air supply circulation to avoid any dead angles, which can make the temperature distribution in the test area uniform.
◆ The air path is designed to circulate the air outlet and return air, and the wind pressure and wind speed meet the test standards, and the temperature can stabilize quickly at the moment of opening the door.
◆ Heating, cooling, and the system is completely independent and effective, reducing the cost of testing, increasing the life expectancy, and reducing the failure rate.
Meets standards
Strictly refer to: GB2423.1-2008 Test A "High Temperature Test Method", GB2423.2-2008 Test B "Low Temperature Test Method" GJB150A.3, GJB150A.4 and other relevant standards for design and manufacturing.
Series selection
Model | GDJW-100 | GDJW-225 | GDJW-500 | GDJW-800 | GDJW-010 |
Inner dimensions | 450X450X500mm | 500X600X750mm | 700X800X900mm | 800X1000X1000mm | 1000X1000X1000mm |
Temperature range | A:0℃~150℃ B:-20℃~150℃?? C:-40℃~150℃ D:-60℃~150℃ E:-70℃~150℃ | ||||
Alternating range | B: -20°C~85°C, C: -40°C~85°C D model: -60°C~85°C | ||||
Fluctuation/uniformity | ≤±0.5℃/≤±2℃ | ||||
Heating time | -20°C~100°C for about 35min | -40°C~100°C for about 45min | -70°C~100°C for about 55min | ||
Cool-down time | 25°C~-40°C for about 50min | 25°C~-60°C for about 65min | 25°C~-70°C for about 80min | ||
controller | Large screen touch screen temperature and humidity control instrument | ||||
Accuracy range | Setting accuracy: temperature±0.1°C, indication accuracy | ||||
Temperature sensor | Platinum resistor PT100Ω/MV | ||||
Heating system | Fully self-contained, nickel-chromium alloy electrically heated heater | ||||
Refrigeration system | Original French "Taikang", fully enclosed air-cooled compression refrigeration method | ||||
circulatory system | Temperature-resistant and low-noise air-conditioning motor, multi-leaf centrifugal wind wheel | ||||
Enclosure Material | A3 steel plate electrostatic spraying treatment | ||||
Inner box material | SUS304 stainless steel good mirror steel plate | ||||
Insulation material | Polyurethane rigid foam, ultra-fine glass fiber foam | ||||
Door frame insulation | Double-layer silicone rubber door sealing strip resistant to high-low temperature aging | ||||
Duration of the trial | 0~9999 M, H adjustable | ||||
Standard configuration | 1 set of multi-layer heating cream with illuminated glass window, 2 sample racks, and 1 test lead hole φ50mm | ||||
Security | Leakage, short circuit, overtemperature, motor overheating, compressor overpressure, overload, overcurrent protection | ||||
Supply Voltage | AC280V±10% AC380V±10% 50Hz three-phase five-wire system | ||||
Use ambient temperature | 5℃~+30℃ ≤85%R.H | ||||
ZKHS GDJW-010B High-Low Temperature Cycling Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Interior size | 1000*1000*1000mm |
| Temperature range | -20~150℃ |
| Alternating range | -20℃~85℃ |
| Temperature fluctuation | ≤±0.5℃ |
| Heating rate | -20→100℃≈35min;-40→100℃≈45min |
| Cooling rate | 25~-40℃≈50min;25~-60℃≈65min |
| display | Large screen touch screen temperature and humidity control instrument |
| Accuracy range | Setting Accuracy: temperature ± 0.1 ℃, indication Accuracy |
| Temperature transducer | Platinum resistance PT100Ω/MV |
| Heating system | Fully independent system, nickel-chromium alloy electric heating heater |
| Refrigeration system | Original French "Taikang", fully enclosed air-cooled compression refrigeration method |
| Circulatory system | Temperature-resistant and low-noise air-conditioned motor, multi-leaf centrifugal wind turbine |
| Enclosure Material | A3 steel plate electrostatic spray treatment |
| Inner chamber material | SUS304 stainless steel high quality mirror steel plate |
| Thermal insulation material | Polyurethane Rigid Foam, Ultrafine Glass Fiber Cotton |
| Door frame insulation | Double Layer High and Low Temperature Conditioning Silicone Rubber Door Seal |
| Timer | 0~9999 M, H adjustable |
| Safety Devices | Leakage, short circuit, over temperature, motor overheating, compressor overVoltage, overload, overcurrent protection |
| Power | AC280V ± 10% AC380V ± 10% 50Hz three-phase five-wire system |
| Environment temperature | 5~30℃ |
| Environment humidity | ≤85%R.H |
| Temperature Uniformity | ≤±2℃ |
ZKHS GDJW-010B High-Low Temperature Cycling Test Chamber Packing list
Host x1, multi-layer heating and defrosting with lighting Glass window x1 set, test rack x2, test lead hole φ50mmx1, manual x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 2424.7-2024
- ActiveJG/T 25-2017
- ActiveQJ 481-1990
- ActiveGB/T 9979-2005
- ActiveGB/T 23711.2-2019
- ActiveGB/T 10590-2006
- ActiveGB/T 33861-2017
- ActiveGB/T 10592-2023
- ActiveGB/T 32065.7-2015
- ActiveGB/T 2423.63-2019
- Active 10590-2006
- ActiveGB/T 2423.4-2008
- ActiveGB/T 41166-2021
- ActiveGB/T 25261-2018
- ActiveGB/T 2423.102-2008
- AbolishGB/T 2423.34-2005
- ActiveHG/T 5175-2017
- ActiveGB/T 2573-2008
- ActiveGB/T 10589-2008
- ReplacedGB/T 10592-2008


GDJW-010B