Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Thermal Shock Test Chamber> ZKHS> ZKHS WDCJ-162A Thermal Shock Test Chamber

      ZKHS WDCJ-162A High and low temperature impact test box, High and low temperature Impact test machine -20 ℃~ 150 ℃

      ZKHS WDCJ-162A high and low temperature impact test box inner size 450X450X450mm, temperature range -20 ℃~ 150 ℃, temperature fluctuation high greenhouse and low greenhouse are ≤ +/- 2 ℃, sample area temperature fluctuation ≤ +/- 0.5 ℃ (thermostatic), sample area load bearing 20kg, controller 7.0 inch Touchscreen controller, accuracy range +/- 0.1 ℃.

      Brand
      SKU: NB026980
      China ZKHS
      Stock
      Loading…
      Price
      $ 21648.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • ZKHS WDCJ-162A Thermal Shock Test ChamberOverview

        • Specifications
        • Comments
        • FAQs
        WDCJ-162A
        Thermal Shock Test Chamber

        Applications

        ◆This product is suitable for the safety performance test of electronic components, providing reliability test, product screening test, etc. At the same time, through this equipment test, the reliability of the product can be improved and the quality control of the product can be carried out.

        Box structure

        ◆All functions are controlled by computer, which is a self-developed software with a good operation interface, which makes the user's operation and monitoring easier and more intuitive. The hold function can keep the program you are running at the current state and can be temporarily changed The value of this program segment can be set on the screen as the time parameter, so that the switching of cooling, heating, and blue transfer will be automatically carried out according to the set value.

        Control System

        ◆The cold box and hot box are independently controlled, and the doors are independent of each other, which expands the scope of use of the test box (one box for three purposes), and the product's heat preservation effect can be fully guaranteed.

        ◆The door of the Test Chamber is interlocked with the circulating fan and the blue drive to protect the safety of the operator. Once the door is opened, the power supply of the circulating fan and the blue drive will be cut off automatically.

        ◆There are standard lead hole tubes on the top of the box, which is convenient for users to introduce sensor lines, detection cables and other types of leads into the box.

        ◆The switching time between low temperature zone and high temperature zone is ≤15 seconds, and the temperature recovery time is ≤5 minutes.

        Standards 

        Strictly refer to: GJB150.3A, GJB150.4A, GJB150.5A-2009 high-low temperature impact test standards design and manufacture.

        Series selection

        model

        WDCJ-100L

        WDCJ-300L

        WDCJ-500L

        WDCJ-010L

        Internal dimensions

        450X450X450

        600X600X600

        800X800X800

        1000X1000X1000

        temperature range

        A: -20℃~200℃ B: -40℃~200℃ C: -60℃~200℃ D: -70℃~200℃

        temperature fluctuation

        Both the high temperature room and the low temperature room are ≤±2℃

        Temperature fluctuations in the sample area

        ≤±0.5°C (at constant temperature)

        Load bearing of sample area

        20kg

        30kg

        40kg

        50kg

        controller

        7.0 inch touch screen controller

        Accuracy range

        ±0.1℃

        Cooling System

        Original French "Taikang" fully enclosed air-cooled cascade compression refrigeration method, imported German Copeland semi-closed water-cooled compressor unit

        circulatory system

        Temperature-resistant low-noise air-conditioning motor. Multi-blade centrifugal wind wheel

        temperature conversion time

        ≤15 seconds from low temperature zone to high temperature zone or from high temperature zone to low temperature zone

        temperature recovery time

        ≤5min (related to temperature recovery conditions, namely cooling water temperature, exposure temperature difference, constant temperature time, sample weight)

        Test time

        ~9999 M, H adjustable

        Voltage

        AC380V±10% 50Hz three-phase five-wire system


        VS

        ZKHS WDCJ-162A Thermal Shock Test ChamberSpecifications

        LIST VALUE
        Liner size 450*450*450mm
        Temperature range -20~150℃
        Temperature fluctuation ≤±2℃
        Temperature fluctuation in sample area ≤ ± 0.5 ℃ (at constant temperature)
        Sample area load bearing 20kg
        Control method 7.0 inch touch screen Controller
        Accuracy range ±0.1℃
        Refrigeration system Original French "Taikang" fully enclosed air-cooled cascade compression refrigeration method, imported German Copeland semi-enclosed water-cooled Compressor unit
        Circulatory system Temperature-resistant and low-noise air-conditioned motor. Multi-leaf centrifugal wind turbine
        High and low temperature switching time ≤15s
        Temperature recovery time ≤5min
        test time ~ 9999 M, H adjustable
        Power AC380V ± 10% 50Hz three-phase five-wire system

        ZKHS WDCJ-162A Thermal Shock Test Chamber Packing list

        host X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        I want to test the Reliability of electronic components. Do you have a recommended test chamber?
        [A]
        WDCJ-162A high and low temperature impact test box is specially used for Reliability testing and screening of electronic components, which can simulate the environment of rapid temperature change, effectively find potential defects of products, and improve the quality control level.
        [Q]
        We do product environmental adaptability test, need to quickly switch between high and low temperature, choose which model is suitable?
        [A]
        WDCJ-162A is suitable. Its high and low temperature zone conversion time is ≤ 15 seconds, and the temperature recovery is ≤ 5 minutes. It can quickly and accurately simulate the harsh temperature Impact environment. It fully complies with military standards such as GJB150 and is often used for Reliability verification in military, automotive electronics and other fields.
        [Q]
        What is the difference between this high-low-temperature chamber A and B?
        [A]
        A is without refrigeration, only high temperature and high humidity, B is with refrigeration, high temperature and high humidity, low temperature and low humidity can be done.
        [Q]
        Does this high and low temperature impact test box meet the GB/T2423.2 standard?
        [A]
        The high and low temperature impact test box is suitable for GB/T2423.2, please consult customer service for detailed application definition
        ZKHS
        ZKHS WDCJ-162A High and low temperature impact test box, High and low temperature Impact test machine -20 ℃~ 150 ℃
        Service
        Focus on online sales of Lab Testing Instruments