HZAOC AK-PCT-350 PCT high Voltage accelerated aging box PCT test box
Internal dimensions of HZAOC AK-PCT-350 PCT high Voltage accelerated aging box are φ 350 × 500mm, outer box size 850 × 1000 × 1550mm, operating temperature 121 ℃; 132 ℃, using Humidity 100% RH saturated vapor Humidity, using vapor pressure (absolute pressure) 1 atmosphere pressure + 0.0Kg/cm2-2.0Kg/cm2.
hzaoc-
CHINA DHG-401A aging Test Chamber 1500W/200 ℃
$ 532.00 -
HZAOC RLH-800 Hot Air Aging Oven, stainless steel liner ventilation 8-20 times/hour 800L
$ 6957.00 -
YIHENG BHO-402A aging Test Chamber
$ 2357.00 -
ZKHS QLH-100 Ventilation Conditioning Test Chamber 4KW/200 ℃
$ 4299.00 -
ZKHS QLH-500 Ventilation Conditioning Test Chamber 5.5KW/200 ℃
$ 5823.00
overview
The high-Voltage acceleration Test Chamber is used to test the moisture capacity of semiconductor packaging, the product to be tested is subjected to severe temperature, humidity and pressure, and the moisture will penetrate into the packaging along the interface between the colloid or the colloid and the wire frame, multilayer circuit boards, photovoltaic modules, EVA, IC, LED, LCD, magnetic materials, polymer materials and other products, and test the pressure resistance and air tightness of the products.
Equipment features:
1. It has the function of automatic water addition, and automatically replenishes water when the water is too low during the test.
2. The test process runs automatically to the end of the test, which is easy to use.
3. Temperature control: The LED digital temperature controller can be used to accurately set the test temperature, control and display.
4. Timer: LED digital timer, when the temperature in the pot reaches the timer, it will start to time to ensure that the test is complete.
5. Accurate pressure/temperature gauge shows the pressure and relative temperature in the pot at any time.
6. During operation, the water unit automatically discharges unsaturated steam to achieve better steam quality.
7. One-piece silicone door gasket with good air density and long service life.
8. The inside is polished, durable and beautiful.
Security
Thermostat detection protection, the first stage of high temperature protection, the first stage of high pressure protection, door pressure limit, Water Tank water shortage alarm power off, temperature heater protection, humidity humidifier protection, second stage high temperature protection, second stage high pressure protection, third stage emergency pressure relief protection, manual pressure relief protection, automatic pressure relief, etc.
Enforce the standard
1.IEC60068-2-66
2.JESD22-A102-B
3.EIAJED4701
4.EIA/JESD22
hzaoc AK-PCT-350 PCT high Voltage accelerated aging boxSpecifications
| LIST | VALUE |
|---|---|
| operating temperature | 121℃;132℃ |
| Humidity | 100% RH Saturated Vapor Humidity |
| Use vapor pressure (absolute pressure) | 1 environment atmospheric pressure + 0.0Kg/cm2-2.0Kg/cm2; (3.0KG/cm2 belongs to special specifications) |
| Temperature Resolution | 0.1 |
| Pressure resolution | Pointer 0.1 |
| control stability | Temperature: +/- 0.5 ℃, Humidity: 100% |
| Circular mode | Water vapor natural convection cycle |
| Safety protection device | Water shortage protection, overpressure protection, (with automatic/manual water replenishment function, automatic pressure relief function) |
| Humidity range | 100% RH saturated vapor |
| Pressure range | Gauge pressure + 0.2~ 2.0kg/cm2, pressurization time: about 50 minutes |
| gauge pressure | + 0.2~ 3.5kg/cm2 Pressurization time: 55 minutes |
| Circular mode | Water vapor natural convection cycle |
| Power supply Voltage | AC380V,50/60Hz |
hzaoc AK-PCT-350 PCT high Voltage accelerated aging box Packing list
host x1, sample holder x1, warranty card x1, manual x1, certificate x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 45939-2025
- ActiveIEC
- ActiveGB/T 44357-2024
- ActiveJB/T 7444-2018
- ActiveHG/T 5229-2017
- ActiveGB/T 43489-2023
- ActiveASTM D573-2019


AK-PCT-350