HZAOC RLH-010 Hot Air Aging Oven, Ventilated Air Oven 300 ℃/1000L
Temperature range RT + 10~ 300 ℃, Temperature Uniformity +/- 1 ℃, stainless steel liner and forced circulation system, with over-temperature protection and independent ventilation control function.
hzaoc-
HZAOC RLH-225 Hot Air Aging Oven, stainless steel liner automatic ventilation system
$ 4159.00 -
HZAOC RLH-500 Hot Air Aging Oven, Ventilated Air Oven
$ 5558.00 -
YIHENG BHO-401A aging Test Chamber
$ 1597.00 -
ZKHS QLH-010 Ventilation Conditioning Test Chamber 6.5KW/200 ℃
$ 7750.00 -
ZKHS QLH-500 Ventilation Conditioning Test Chamber 5.5KW/200 ℃
$ 5823.00
Applications
The hot air aging Test Chamber is suitable for heat resistance test of non-metallic materials, ventilation aging test of electronic parts and plasticized products.
Box structure
1. The outer shell is processed by A3 steel plate CNC machine tool, and the inner tank is made of high-quality stainless steel plate. The insulation material is high-density glass fiber cotton, and the thickness of the insulation layer is 150mm.
2. Stirring system: It adopts high-power long-axis fan motor, high-temperature-resistant stainless steel shaft and impeller to achieve strong convection and vertical diffusion cycle. The ventilation system of the equipment is automatically controlled, and the ventilation volume is adjustable.
3. The sample rack is driven by a geared motor and can rotate.
Heating and Humidification System
1. Use far-infrared nickel alloy to heat the heating wire at high speed.
2. Heating and ventilation are completely independent systems.
3. The output power of temperature control is calculated by microcomputer to achieve high precision and effective power consumption
Control System
1. Temperature control: It is controlled by a high-precision touch screen temperature controller.
2. Time control: Imported time relay is adopted, and H, M, S can be set arbitrarily.
3. Electrical components of the equipment: all adopt the "Schneider" brand and domestic (CN) familiar brands.
4. Heating system: Far-infrared kneading chromium alloy is used for high-speed heating and electric heating.
5. The rotation of the sample rack, the control of the ventilation system and the heating system are independent, and are controlled by the switch on the operation panel.
Protection System
Overall equipment overheating, fan overheating protection, overall equipment phase loss/reverse phase protection, overall equipment timing, other protections include leakage, running instructions, automatic shutdown after fault alarm, etc.
Executive standard
1.GB/T3512-2001;
2.JB/T7444;
3.IEC540
hzaoc RLH-010 Hot air aging boxSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | RT+10~300℃ |
| Temperature Fluctuation | +/- 0.5 ° C (without load) |
| Temperature Uniformity | ±1℃ |
| heating rate | 3~5℃/min |
| Timer Range | 1~ 9999 (s, m, h) adjustable |
| ventilation time | 1~ 99 (s, m, h) adjustable |
| ventilation volume | 8~ 20 times/hour |
| ventilation method | Forced ventilation, forced air intake of the fan, automatic ventilation by adjusting the Flow rate of the Flow rate meter |
| Specimen turntable | Two-layer stainless steel turret |
| circular mode | Fan forced circulation |
| Power supply voltage | 380V three-phase five-wire system |
| Liner size | 1000*1000*1000mm |
| Dimension | 1800*1400*1700mm |
| Rotation speed of turntable | 10rpm |
hzaoc RLH-010 Hot air aging box Packing list
host x1, sample holder x1, silicone plug x1, warranty card x1, manual x1, certificate x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB 45671-2025
- ActiveGB/T 44357-2024
- ActiveFZ/T 01008-2008
- ActiveSH/T 1542-2023
- ActiveJB/T 7444-2018
- ActiveHB 5319-1993
- ActiveHG/T 5229-2017
- ActiveNF
- ActiveJC/T 2678-2022
- ActiveGB/T 17782-1999
- ActiveGB/T 9871-2008
- ActiveGB/T 12747.2-2017
- ActiveGB/T 3512-2014
- AbolishGB/T 18244-2000
- ActiveASTM D573-2019
- ActiveGB/T 37259-2018
- ActiveGB/T 3903.7-2019
- ActiveGB/T 7141-2008
- ActiveGB/T 22894-2008
- ActiveGB/T 464-2008


RLH-010