FANGRUIs ULR Ultra Low Viscosity Adapter, Enhanced, Optional
FANGRUI ULR Ultra Low Viscosity Adapter is used for Viscometer matching, which can be applied to the measurement of low Viscosity objects. It consists of cylindrical rotor and tubular sleeve.
FangRui-
HUINUO HBDV-2 Digital Rotational Viscometer with L0 rotor
$ 1979.00 -
HUINUO NDJ-5S Digital Rotational Viscometer Digital Viscosity Testing Instrument 100,000 CP
$ 350.00 -
HUINUO NDJ-5S Digital Rotational Viscometer with RTD temperature sensor
$ 469.00 -
MODERNER NDJ-5S Digital Rotational Viscometer viscosity range: 1~ 100000mPa · s
Login -
FANGRUI RTD temperature probe, temperature range 0~100 ℃ optional accessories
$ 131.00
Introduction
The Enhanced Ultra Low Viscosity Adapter ULR is used in conjunction with the Foray Viscometer for accurate and repeatable measurements of low viscosity objects. Both Newtonian and non-Newtonian fluids are applicable. The Ultra Low Viscosity Adapter ULR consists of a precision cylindrical rotor and a precision tubular sleeve (sample cup). The rheologically rigorous cylindrical structure design allows it to perform accurate viscosity measurement and shear rate determination.

Adapter detail drawing
Ultra Low Viscosity Adapter Features
● Designed for low viscosity fluid measurement
● Jacketed and non-jacketed specifications are available
● The lowest detection limit is 1cP, the range depends on the type of viscometer used
● Accurate measurement at specified shear rates for detailed product analysis
● The stainless steel material is easy to clean and can withstand the working temperature range of -40℃-250℃
● Sample volume 18-20mL 
Structure of Ultra Low Viscosity Adapter
1. Mounting bracket
2. Water bath jacket (ULR-PLUS included)
3. Sample cup
4. Sample cup holder with knob
5.0 rotor
Application Scenario

FangRui ULR Ultra Low Viscosity AdapterSpecifications
| LIST | VALUE |
|---|---|
| Capacity | 18~20ml |
| material | stainless steel |
| Minimum detection limit | 1cp |
| Allowable Operating Temperature | -40~250℃ |
FangRui ULR Ultra Low Viscosity Adapter Packing list
Mounting bracket x1, sample cartridge x1, sample collet x1, 0 #rotor x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to choose a Rotational Viscometer? This is enough
- Principle characteristics and application analysis of spot inks viscosity Measurement Instrument
- Comparison table of rotor speed and test range of each model
- Precautions for the use of Rotational Viscometer
- AbolishGB/T 14235.8-1993
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveSY/T 5377-2007
- ActiveJB/T 9357-1999
- ActiveGB/T 10247-2008


ULR





