Rongjida DM-III minimum film formation temperature Tester
Rongjida minimum film formation temperature meter DM-III layer interval of 20mm, layer plate temperature range -10 ℃~ 50 ℃ between arbitrary adjustment, DM-III layer plate detection point 13 points, inspection table shows 16 points.
RongJiDa-
PUSHEN MFFT minimum film forming temperature (MFFT) Tester
$ 3568.00 -
TQC VF9700 MFFT20 minimum film forming temperature (MFFT) Tester -30~ + 250 ℃
$ 60310.00 -
JINGKELIAN QMB-II minimum film forming temperature (MFFT) Tester GB9267 standard
$ 2779.00 -
TQC VF9600 MFFT10 minimum film forming temperature (MFFT) Tester -10~80 ℃
$ 39193.00 -
JINGKELIAN QMB minimum film forming temperature (MFFT) Tester, stainless steel profiled temperature layer
$ 2835.00
Introduction
Developed according to GB/T9267-2008 standard. At the same time, it meets the test requirements of GB/T 11175-2002. It is used to determine the minimum film-forming temperature of polymer emulsions and interface treatment agents. When polymer emulsions are used as surface treatment agents for coatings, adhesives, chemical fiber fabrics, leather and paper, their film-forming properties are one of the most important properties. . Using multi-channel inspection digital display, the temperature control data is accurate, and the calibration is convenient. Fully automatic measurement, no human error, simple, accurate, fast and convenient. It can simply, intuitively and accurately determine the minimum film-forming temperature of polymer emulsion.
Product principle
A cooling source and a heating source are respectively set on a suitable metal plate, and kept at the constant temperature point of the set temperature, and different temperature gradients are generated on the metal plate through the principle of metal heat conduction. A uniform thickness of sample is coated on the temperature gradient plate, and the sample is subjected to the temperature on the gradient plate to evaporate water to form a film. Due to the different temperatures on the gradient plate, the phenomenon of film formation on the sample is also different. The part where the dividing line is found is the MFT temperature of the sample.
RongJiDa DM-III Minimum film formation temperature TesterSpecifications
| LIST | VALUE |
|---|---|
| Layer operation temperature range | -10~50℃ |
| Layer spacing | 20mm |
| Layer board detection point | 13 point |
| Inspection form display | 16 point, of which 1 to 13 point is the working layer temperature, 14 point is the instrument environment temperature, 15 and 16 point are the inlet and outlet temperature of the chilled down water |
RongJiDa DM-III Minimum film formation temperature Tester Packing list
Host: one; Plexiglass cover: one; Safety tube: four; Manual: one; Certificate of conformity: one
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the properties of dry film?
- Tester for film-forming process, physical drying, chemical curing, and minimum film-forming temperature of coatings
- Minimum film forming temperature (MFFT): from theory to practice
- What is the minimum film formation temperature? How to reduce MFT
- How to understand the minimum film forming temperature of emulsion?
- ActiveHG/T 4448-2012
- ActiveGB/T 20623-2006
- ActiveGB/T 9267-2008
- AbolishGB/T 11175-2002
- ISO 2115-1996
- AbolishGB/T 9267-1988


DM-III