BOZHEN HH. CP-01 Co2 Incubator gas sleeve/160L
BOZHEN HH. CP-01 Co2 Incubator Temperature range RT + 5 ℃~ 50 ℃, Temperature Fluctuation +/- 0.2 ℃, Temperature resolution 0.1 ℃, liner size 500 × 500 × 650mm, volume 160L, shelf (standard) 2 pieces, HH. CP-01 can heat the inner Glass door, which can effectively prevent the condensation generated by the Glass door and prevent the possibility of microbial contamination caused by the condensation of the Glass door.
BoZhen-
JINGQI MHP-250 Mold Incubator 250L
Login -
SANFA SHP-160DA low temperature Biochemical Incubator -20 ℃/160L
$ 2364.00 -
HUITAI LRH-70FN biochemistry cultivating box 70L
Login -
RONGHUA GHP-150C digital lighting chamber volume: 150L
$ 804.00 -
Kenton DNP-9052 Precision LCD screen electric Incubator 50L
$ 512.00
Introduction
The CO2 Incubator is an upgraded product of the HH.CP-series CO2 Incubator. Guided by the needs of users, the factory constantly develops new technologies and applies them to products, breaking through the defects of low control accuracy, large error of carbon dioxide gas measurement and large consumption of carbon dioxide gas in the existing domestic (CN) carbon dioxide Incubator.
Overview of uses
Carbon dioxide Incubators are used by modern medicine, biochemistry and agricultural science research institutes and industrial production departments as biological cells, tissues, bacterial cultures, etc.
Features
1. It can be stacked (two layers), which is convenient for the full use of laboratory space, and the microcomputer controller can control the temperature accurately and reliably. The stainless steel liner is used on the shelf, and the four corners are semi-circular and excessive, and the shelf bracket can be freely loaded and unloaded, which is convenient for cleaning in the studio.
2. The carbon dioxide inlet is equipped with an effective microbial filter, which can effectively filter bacteria and dust particles in carbon dioxide gas for particles with a diameter of 0.3 um.
Door heating system
CO2 Incubators can heat the inner glass door, which effectively prevents condensation from the glass door and the possibility of microbial contamination due to condensation from the glass door.
Automatic control of circulating fan speed
The speed of the circulating fan is controlled to avoid the volatilization of the sample due to excessive air volume during the test. The safety red energy sound and light alarm prompts the operator to ensure that the test safety operation department has an accident, low temperature, high temperature, over-temperature alarm and long door opening time alarm function.
Series selection
Model | Temperature range °C | Temperature accuracy | Working trough volume mm | Working groove opening mm | Heating power (W) | Circulating pump flow rate L/min |
BZ-200 | -5~95 | ±0.05 | 250X200X150 | 200X140 | 600 | 6 |
BZ-201 | -10~95 | ±0.05 | 250X200X150 | 200X140 | 6 | |
BZ-202 | -20~95 | ±0.05 | 250X200X150 | 200X140 | 6 | |
BZ-203 | -30~95 | ±0.1 | 250X200X150 | 200X140 | 6 | |
BZ-204 | -40~95 | ±0.1 | 250X200X150 | 200X140 | 6 | |
BZ-300 | -5~95 | ±0.05 | 300X250X200 | 250X160 | 800 | 6 |
BZ-301 | -10~95 | ±0.05 | 250X200X150 | 250X160 | 6 | |
BZ-302 | -20~95 | ±0.05 | 250X200X150 | 250X160 | 6 | |
BZ-303 | -30~95 | ±0.1 | 250X200X150 | 250X160 | 6 | |
BZ-304 | -40~95 | ±0.1 | 250X200X150 | 250X160 | 6 |
BoZhen HH.CP-01 Co2 IncubatorSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | RT+5~50℃ |
| Temperature Fluctuation | ±0.2℃ |
| Temperature Resolution | 0.1℃ |
| Liner material | stainless steel |
| Liner size | 500*500*650mm |
| Volume | 160L |
| Shelf (standard) | 2pcs |
| Power supply Voltage | 220V 50Hz |
| Input Power | 720W |
| Environmental temperature | 5℃~35℃ |
| Dimension | 630*605*935mm |
| CO2 range | 0~20% (valve type) |
| CO2 recovery time | ≤ concentration value X1.2min |
| Humidification mode | natural evaporation |
BoZhen HH.CP-01 Co2 Incubator Packing list
Host X1, Shelf X2, Operation Manual X1, Warranty Card X1, Certificate of Conformity X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HH.CP-01