QILI MN-B reflection blackness meter
MN-B reflection blackness meter is a high sensitivity reflectance measuring instrument for the measurement of black and dark gray surface blackness.
QiLi-
JFL JFL-R Portable reflectance Tester for hiding power of Paints, colorants, etc
$ 338.00 -
PUSHEN JFB-I portable reflectivity meter reflectance range 0-100
$ 483.00 -
YONGLIDA C84-III desktop reflectivity meter 0~100
$ 472.00 -
MODERNER C84-III reflectivity meter for white and shallow Paints hiding power measurement and comparison of Coating and Paints
Login -
AMITTARI ARM-216 hiding ratio 450nm Light source reflectance meter
$ 498.00
MN-B reflective blackness meter is a highly sensitive reflectivity measuring instrument used to measure the blackness of black and dark gray object surfaces. The measurement accuracy of the instrument has a good correlation with the densichon type reflection photometer specified by the American Society for Testing and Materials (ASTM) standards. The measurement circuit of the instrument uses high-precision, low-drift integrated operational amplifiers and large-scale integrated circuit A/D converters, so the instrument has stable readings, reliable operation, and is easy to use.
application
Determination of tinting strength and blackness of carbon in ink coatings, carbon black and rubber industries.
Features
1. Small size, light weight, truly portable.
2. Power-saving, worry-free and effective, one battery can last for nearly 60 hours to measure nearly 10,000 data.
3. High stability, ready to test.
4. Quartz crystal standard version with extremely low annual change rate.
5.LED long life light source.
6. Automatically shut down to save power and prevent battery leakage from causing failure.
7. You can choose a powder sample box and a sample press for accurate powder measurement.
8. Standard grayscale transfers standard values, which is accurate and reliable.
QiLi MN-B blackness MeterSpecifications
| LIST | VALUE |
|---|---|
| Indication interval | 0~199.9 |
| Resolution | 0.1 |
| Repeatability | ±0.2 |
| Error of indication | ±1.2 |
| irradiation conditions | 45/0° |
| Measurement aperture | 12*26mm |
| Power | One AA dry battery is enough. (1.5v) |
| Dimensions | 114*32*64mm |
| Net Weight | 300g |
QiLi MN-B blackness Meter Packing list
host x1, manual x1, certificate of conformity x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- AbolishASTM
- ActiveJG/T 235-2014
- ActiveJC/T 1040-2020
- ActiveGB/T 7048-2012
- ActiveJJF 1232-2009
- ActiveGB/T 9780-2013
- ActiveGB/T 9757-2001
- ActiveASTM D2805-2023
- ActiveGB/T 5211.17-1988
- ReplacedJG/T 172-2005
- ISO 2814-1973
- AbolishGB/T 23981-2009
- ActiveGB/T 13452.3-1992
- ActiveGB/T 5211.17-1988


MN-B
MN-BII