INESA SGW X-5 Melting point meter capillary method + hot stage method
Adopt PID temperature adjustment technology, equipped with microscope camera and color LCD touch screen, support capillary method and hot table method, suitable for solid and powder samples. With data storage, USB transfer to PC and printing functions, it is convenient to view and record results.
INESA-
SUOGUANG WRS-1A Melting point meter melting point measurement range: room temperature~ 320 ℃
$ 1075.00 -
YOUKE YK3654 melting point Tester
$ 630.00 -
INESA WRS-1B Digital Melting point meter 320 ℃
$ 1470.00 -
SUOGUANG MPZ-3B Melting point meter 50~320 ℃
$ 3180.00 -
INESA SGW-630 Automatic image oil melting point (sliding point) instrument
$ 4035.00
Features
PID temperature regulation technology is used to accurately control the change of measured temperature.
The microscope camera and color LCD touch screen visualize the melting process of the sample under the microscope on the screen, allowing users to observe and control the measurement process more accurately.
The measured temperature values (primary melting, final melting) data can be stored for easy viewing at any time.
The test results can be transferred to a PC for processing via a USB interface, or they can be connected to a micro printer to print the test results.
The instrument has two melting point measurement methods, capillary method and hot stage method, which can measure solid and powder samples to meet the needs of different users.
INESA SGW X-5 Melting point meterSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | RT+~360℃ |
| Measuring method | visual |
| Temperature Resolution | 0.1℃ |
| Heating rate | 0.2/0. 5/1/1 5/2/3/4/5 ℃/min |
| error of indication | Capillary method: ≤ 200 ℃: +/- 0.4 ℃; > 200 ℃: +/- 0.7 ℃; Hot stage method: room temperature~ 100 ℃: +/- 0.4 ℃; 100 ℃~ 200 ℃: +/- 0.6 ℃; 200 ℃~ 300 ℃: +/- 0.8 ℃ |
| Repeatability | ±0.3℃(1.0℃/min) |
| linear Heating rate error | ±10% |
| Capillary tubing size | Outer diameter is 1.4mm; Inner diameter is 1.0mm; Length is 90mm. |
| Sample height | 3mm |
| Slide size | 76.2*25.4mm |
| Field of view diameter | Æ2.0mm |
| Data storage | 1000 sets |
| Display mode | 7-Inch LCD touch screen |
| Calibration method | Multipoint calibrated |
| Interface | USB (connected to the host PC), U disk |
| Printer model | CK NT-T24S (optional) |
| Power Supply | 220V±22V 50Hz±1Hz |
| Dimension | 310*230*505mm |
| Net Weight of instrument | 4Kg |
| Slide size | 18*18mm |
| Slide thickness | 0.17mm |
| Slide thickness | 0.8mm |
INESA SGW X-5 Melting point meter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


SGW X-5






