NIRUN CAP-10 Cone Plate Rheometer Rotor 50~100000mPa · s
The NIRUN CAP-09 Cone Plate Rheometer is an optional CAP rotor for the NTV-CAP3H Cone Plate Rheometer with a shear rate of 5.0N and a sample size of 170 μL for a viscosity range of 50 to 100,000 mPa · s.
NiRun-
NIRUN CAP-10 Cone Plate Rheometer Rotor 50~100000mPa · s
$ 658.00 -
NIRUN CAP-04 Cone Plate Rheometer Rotor 150~300000mPa · s
$ 658.00 -
NIRUN CAP-05 Cone Plate Rheometer Rotor 300~600000mPa · s
$ 658.00 -
NIRUN NTV-LP2 Digital Viscometer (Rheometer) 0.3-100 MmPa · s
$ 3251.00 -
NIRUN CAP-06 Cone Plate Rheometer Rotor 750~1500000mPa · s
$ 658.00
Introduction
NIRUN CAP-09 cone-plate rheometer is an optional CAP rotor for NTV-CAP3H cone-plate rheometer. The shear rate is 5.0N, the sample volume is 170μL, and the applicable viscosity range is 50~100000mPa·s.
Applications
Medium viscosity fluid: hot melt adhesive, coating, resin, starch, screen printing ink, surface treatment, organic solvent, cream, food, gel, chewing gum, plastisol, etc.
High viscosity fluids: adhesives, gels, sealants, asphalt, printing inks, chocolate, tar, molasses, pastes, synthetic polymers, epoxy polymers, vinyl esters, roofing materials
Parameter comparison table
| Rotor number | shear rate | sample size | Rotating speed |
| CAP-01 | 13.3N | 67μL | 20-37500 |
| CAP-02 | 13.3N | 38μL | 37-75000 |
| CAP-03 | 13.3N | 24 μL | 75-150000 |
| CAP-04 | 3.3N | 134μL | 150-300000 |
| CAP-05 | 3.3N | 67μL | 300-600000 |
| CAP-06 | 3.3N | 30μL | 750-1500000 |
| CAP-07 | 2.0N | 1700μL | 32-63000 |
| CAP-08 | 2.0N | 400μL | 125-250000 |
| CAP-09 | 2.0N | 100μL | 500-1000000 |
| CAP-10 | 5.0N | 170μL | 50-100000 |
| Other parameters | |||
| measurement accuracy | ±2% | ||
| Plate temperature range | 5℃~150℃ | ||
| temperature accuracy | ±0.1℃ | ||
NiRun CAP-10 rotorSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 50~100000mPa·s |
| Rotor speed | 5~1000rpm |
| shear rate | 5.0N |
| Measurement Accuracy | ±2%F.S |
| sample size | 170µL |
NiRun CAP-10 rotor Packing list
Rotor X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Methods for Verifying the Accuracy of a Digital Viscometer
- Classification, Principle, Structure and Operation of SWIRL/spin Rheometer
- Digital Viscometer Tips [Must Read Dry Goods]
- Viscometer temperature controlled heater measurement Viscosity operating procedures
- Nerun STM-2T Stormer Viscometer User Manual
- Nerun: Correction of Digital Viscometers
- Nirun Viscometer Small Sample Adapter Instructions for Use
- A must read for beginners using digital Viscometers
- How Digital Viscometers Work
- 5 points to note when using online Viscometers


CAP-10