Qnix 5500 eddy Current paints Thickness Gauge split 3mm
Split eddy Current Thickness Probe, Thickness range 0~3000 microns, 2-inch large color LCD screen, the screen can be turned over from multiple angles, can be used for bridge cavity and Water Tank, outdoor environment thickness measurement.
Qnix-
PHYNIX Surfix SX-F0.5A iron-based micro probe coated platings Thickness Gauge 500μm
Login -
LANDTEK CM8826n dry Film Thickness Gauge measurement of non-metallic coatings on nonmagnetic metallic substrates
$ 309.00 -
DONGRU DR320 Coating Thickness Gauge electromagnetic induction principle for magnetic metal substrate surface platings measurement
$ 304.00 -
List Magnetik Pocket TOP-CHECK FE Pocket platings Thickness Gauge
$ 1159.00 -
AMITTARI AC-112-200F Coating Thickness Gauge Iron-based film thickness Measurement Instrument
$ 610.00
The QNix 5500 Coating Thickness Gauge is a convenient, durable, and action-friendly instrument for:Modular version, the user can decide which probe to use and the cable. Just in case, remember to disconnect the power supply when replacing the probe!

Whether it's in industrial painting, task testing, corrosion protection or vehicle evaluation, the QNix5500 is designed to provide the fastest and most convenient way to measure coating thickness by simply turning on the machine and placing the instrument on the surface of the workpiece to obtain measurement data, without the need for a series of setup operations.
The large 2-inch color LCD with auto-flip makes it easier to read the measured values in any position, even in harsh lighting conditions. Such as bridge cavities and Water Tanks, or when working outdoors or in strong sunlight. The QNix5500 provides all the necessary statistical information about the current measurement series: the display of the mean, standard deviation, maximum and minimum measurements.
The proper design ensures safe contact and avoids erroneous measurements. For smaller contact areas or inclined components, simply use the probe cable and plug the QNix®5500 into the cable device for a few seconds (only available for the modular version). The angled cable connection makes it easier to work comfortably even when space is limited.
With one-button operation, you can reliably and quickly zero the workpiece on the substrate or on the supplied zero plate.
The right probe for every application – precise, with high accuracy over the entire measuring range: measuring ranges from 1.25 mm to 3 mm to 5 mm, Fe, NFe or dual probes can be used.

Qnix QNix5500+NFe3mm Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 0~3000μm |
| margin of error | ±2~3% |
| Minimum measurement surface | Φ14.5mm |
| Minimum radius of curvature | R70mm |
| thinnest substrate | 0.05mm |
| probe | Line probe |
| Probe size | Φ14.5*34.5mm |
| Probe material | Shell top stainless steel (1.4305); Shell bottom Trogramid ® (CX7323) |
| Probe Weight | 11.9g |
| Unit display | μm |
| statistical function | MAX Maximum, MIN Minimum, Average, Standard deviation |
| Power Supply | 2 * 1.5V (AA) alkaline battery |
| Standards | DIN EN ISO 2808,DIN 50981,DIN 50984,ISO 2178, BS 5411(3&11),BS 3900-C5,ASTM B 499,ISO 2360, ASTM D 1400,ASTM D 1186,ASTM D 7091 |
| Display screen | IPS-LCD, 2-inch, color, 350cd/m2, with a Viewing Angle of 70 ° in all directions. |
| Operating temperature | -20℃-70℃ |
| Battery life | 1 year (1 measurement per second) |
| Protection level | IP65 |
| Shell material | Hard fiberglass * PA12 GF30 |
| Machine Weight | 132g |
| Machine size | 136* 63*42mm |
| Storage temperature | -20~70℃ |
| Maximum workpiece surface temperature for continuous measurement | 80℃ |
| Battery life | > 2 years |
Qnix QNix5500+NFe3mm Coating Thickness Gauge Packing list
QNix5500 host, 1 NFe zero adjustment board, 1 standard piece, factory test report, instruction manual, 2 1.5V AA alkaline batteries, plastic instrument case
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle and application analysis of wood paints Thickness Gauge
- Principle, Application and Type Selection of Electronic Coating Thickness Gauge
- Coating Thickness Gauge for coated Film thickness measurement in vehicle evaluation
- Why Use Coating Thickness Gauges in Powder Coatings?
- Which Coating Thickness Gauge is Right for You?
- Optimizing laboratory management and paint production with Qnix8500 coated Film thickness measurement technology
- Three precautions for the use of paint film coating Thickness Gauges
- Preparation of SiO _ 2 aerogel composite insulating coating
- Film coating thickness measurement in industrial painting and cissing coating
- Application of QNIX Thickness Gauge in coated Film thickness measurement
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ActiveGB/T 13448-2019
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveGB/T 12967.1-2020
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- AbolishGB/T 13448-2006
- ActiveGB/T 11374-2012
- ActiveGB/T 4957-2003


QNix5500+NFe3mm