Qnix 5500 eddy current paints Thickness Gauge split 5mm
EDDY Current thickness measurement principle can be used to test the thickness of nonmagnetic metal substrate coating such as aluminum and copper, the thickness measurement range is 0~5000 μm, and it has good waterproof and dustproof properties and is suitable for thickness measurement under different environmental conditions.
Qnix-
PHYNIX Surfix Easy x I-F HR Iron-based Coating Thickness Gauge 300μm
Login -
KAIRDA N1 standard probe eddy Current NDT530 Coating Thickness Gauge optional probe
$ 173.00 -
Defelsko PosiTector 6000 FNS3 Coating Thickness Gauge metal substrate Automatic substrate type identification and measurement
$ 1882.00 -
DONGRU DR220 (upgraded version) Integrated Coating Thickness Gauge 0-2000μm
$ 226.00 -
TQC SP1114 Destructiveness Thickness Gauge Blade 4 Blade 2~ 200μm Range
$ 271.00
The QNix 5500 Coating Thickness Gauge is a convenient, durable, and action-friendly instrument for:Modular version, the user can decide which probe to use and the cable. Just in case, remember to disconnect the power supply when replacing the probe!

Whether it's in industrial painting, task testing, corrosion protection or vehicle evaluation, the QNix5500 is designed to provide the fastest and most convenient way to measure coating thickness by simply turning on the machine and placing the instrument on the surface of the workpiece to obtain measurement data, without the need for a series of setup operations.
The large 2-inch color LCD with auto-flip makes it easier to read the measured values in any position, even in harsh lighting conditions. Such as bridge cavities and Water Tanks, or when working outdoors or in strong sunlight. The QNix5500 provides all the necessary statistical information about the current measurement series: the display of the mean, standard deviation, maximum and minimum measurements.
The proper design ensures safe contact and avoids erroneous measurements. For smaller contact areas or inclined components, simply use the probe cable and plug the QNix®5500 into the cable device for a few seconds (only available for the modular version). The angled cable connection makes it easier to work comfortably even when space is limited.
With one-button operation, you can reliably and quickly zero the workpiece on the substrate or on the supplied zero plate.
The right probe for every application – precise, with high accuracy over the entire measuring range: measuring ranges from 1.25 mm to 3 mm to 5 mm, Fe, NFe or dual probes can be used.

Qnix QNix5500+NFe5mm Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 0~5000μm |
| margin of error | ±2~3% |
| Minimum measurement surface | Φ14.5mm |
| Minimum radius of curvature | R70mm |
| thinnest substrate | 0.05mm |
| probe | Line probe |
| Probe size | Φ14.5*34.5mm |
| Probe material | Shell top stainless steel (1.4305); Shell bottom Trogramid ® (CX7323) |
| Probe Weight | 11.9g |
| Unit display | μm |
| statistical function | MAX Maximum, MIN Minimum, Average, Standard deviation |
| Power Supply | 2 * 1.5V (AA) alkaline battery |
| Standards | DIN EN ISO 2808,DIN 50981,DIN 50984,ISO 2178, BS 5411(3&11),BS 3900-C5,ASTM B 499,ISO 2360, ASTM D 1400,ASTM D 1186,ASTM D 7091 |
| Display screen | IPS-LCD, 2-inch, color, 350cd/m2, with a Viewing Angle of 70 ° in all directions. |
| Operating temperature | -20℃-70℃ |
| Battery life | 1 year (1 measurement per second) |
| Protection level | IP65 |
| Shell material | Hard fiberglass * PA12 GF30 |
| Machine Weight | 132g |
| Machine size | 136* 63*42mm |
| Storage temperature | -20~70℃ |
| Maximum workpiece surface temperature for continuous measurement | 80℃ |
| Battery life | > 2 years |
Qnix QNix5500+NFe5mm Coating Thickness Gauge Packing list
QNix5500 host, 1 NFe zero adjustment board each, 1 standard piece, factory test report, instruction manual, 2 1.5V AA alkaline batteries, plastic instrument case
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle and application analysis of wood paints Thickness Gauge
- Principle, Application and Type Selection of Electronic Coating Thickness Gauge
- Which Coating Thickness Gauge is Right for You?
- Consequences of poor coating thickness control
- Concept and basic knowledge of coating Thickness Gauge
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Synthesis of Hyperbranched Resin and Its Application in Polyurethane Coatings
- Film coating thickness measurement in industrial painting and cissing coating
- Optimizing laboratory management and paint production with Qnix8500 coated Film thickness measurement technology
- Coating Thickness Gauge for coated Film thickness measurement in vehicle evaluation
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ActiveGB/T 13448-2019
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveGB/T 12967.1-2020
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- AbolishGB/T 13448-2006
- ActiveGB/T 11374-2012
- ActiveGB/T 4957-2003


QNix5500+NFe5mm