QNix 9500Pro + dual-use Film Thickness Gauge 1250μm built-in probe Film Thickness Gauge
Built-in dual-function probe, using magnetic Induction and eddy Current thickness measurement principle, thickness measurement range of 0~1250 microns, support independent measurement allowable value, can store 10 sets of calibrated memory value.
Qnix-
Defelsko FLS ultra-thick coating probe 38mm/+/- 3%
$ 1561.00 -
LEEB leeb252 Coating Thickness Gauge magnetic Induction/eddy Current dual-use automatic identification substrate
Login -
Leeb222 (N1) eddy current Thickness Gauge for non-magnetic metal substrates
Login -
Defelsko NRS split 90 ° conventional probe
$ 853.00 -
German EPK probe F1.6/90 Thickness Gauge probe, extended 6mm line, thickness measurement range 0~1600um
$ 2541.00
QNix9500, rugged, user-friendly interface, reliable quality, multi-purpose and high precision.
QNix9500 has considerable characteristics for the quality control of product production in the process of industrial anti-corrosion, spraying, and surface treatment, whether in compliance with standards or technical parameters. The newly developed QNix9500 PC software enables faster and more efficient management of documentation and inspection reports than ever before. Every QNix9500 is manufactured entirely in Germany.
The Enhanced+ Thickness Gauge is a further upgrade from the Enhanced Gauge and has the following unique features:
1. The calibration supports ISO19840 zero offset, ISO19840 2 points, SSPC PA2 zero offset, SSPC PA2 2 points, AS 3894.3 Switzerland, SIS 184160 Australia.
2. In terms of data storage, it supports 100 tasks, each task has 100 areas, each region has 10,000 points, and the total storage capacity is 2,000,000 readings.
3. Support ISO 19840, SSPC PA2 (80/120) (level 1-5), IMO PSPC (90/10)

Features
1. High-precision measurementEnsure that the quality results are effective
• High-precision measurement in the full range
• High repeatability of measurement results
• Temperature compensation in the probe
• Guaranteed measurement accuracy on curved surfaces and small workpieces
• Easy indexing on rough, smooth, and curved substrates
2. Solid and durable protectionLong-term use under the conditions of satisfying the evil strategy
• Fiberglass included, consisting of 5 components in accordance with IP64
• Waterproof and light-proof
• Three layers of shock protection
• LCD window glass is scratch and chemical resistant (H6 rating)
• Operating temperature -20°C-70°C
• Stainless steel probe with dust film
3. The use of ergonomic design to save time, can be used quickly and continuously without fatigue
• Overrun indicator, LED directly on the LCD and probe
• High-brightness 24-inch LCD, which can be viewed at a 70° angle
• Adjust the brightness of the LCD automatically or manually under sunlight to the best effect display
• Large tactile buttons and low weight medium
• Flip display 0°, 90°, 180°, 270°
4. Flexibility and scalability
• The main machine can be adapted to Fe (iron-based), NFe (non-iron-based),Fe/NFe (iron-based/non-iron-based) dual-purpose probes
• The main unit can be adapted to other types of probes
• Can be equipped with both integrated and split probes
• Quick and easy plug-and-play probe replacement
• Rapid adaptation to meet different needs
5. Friendly interface that is easy for users to understand, intuitive and operable, saving time and money
• Simple calibration for standard use
• The host and PC software are guided by intuitive menus, and the report can be reached in three steps
• Customizable keys for quick and direct single operation
• Pre-configured as standard
Diagram of the display

QNIX9500 Thickness Gauge Specification Drawing

Qnix QNix 9500P+Fe/NFe1.2mm Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|
Qnix QNix 9500P+Fe/NFe1.2mm Coating Thickness Gauge Packing list
QNix9500Pro host, 2 zero adjustment boards, 2 standard pieces, factory test report, instruction manual, 2 1.5V AA alkaline batteries, plastic instrument case
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Which Coating Thickness Gauge is Right for You?
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Principle, Application and Type Selection of Electronic Coating Thickness Gauge
- Optimizing laboratory management and paint production with Qnix8500 coated Film thickness measurement technology
- QNix ® 9500 Coating Thickness Gauge Operation Test FAQ
- Consequences of poor coating thickness control
- QNix ® 9500 Coating Thickness Gauge Measuring Probes FAQ
- Preparation of SiO _ 2 aerogel composite insulating coating
- Film Thickness Gauge and its calibration method
- Principle characteristics and application of silver Film Thickness Gauge
- ActiveGB/T 44757-2024
- ActiveGB/T 13448-2019
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 5367.1-2018
- ActiveGB/T 4956-2003
- AbolishGB/T 13448-2006
- AbolishGB/T 4956-1985
- ActiveGB/T 5209-1985
- ActiveQB/T 2183-1995
- ActiveGB/T 1733-1993
- ActiveGB/T 4957-2003


QNix 9500P+Fe/NFe1.2mm






