PNSHAR PN-SPT towel permeability Tester
PN-SPT towel permeability Tester is developed according to the national standard GB/T 8939 and GB/T 28004, a testing instrument for towel penetration and diaper penetration performance.
PNshar-
YUZHOU PG-1A metallographic sample polishing machine, the diameter of the throwing plate is 230mm
$ 319.00 -
DZ3500A carbon black content Tester carbon black analyzer
Login -
CHINA NBC-5025B 360 degree wire swing testing machine
$ 1386.00 -
AMITTARI FM-210V10 Portable Flow Meter 0.01-10 m/s
$ 643.00 -
Jingyi JY-40B double barrel paint mixer, double barrel inks paint vertical mixer
$ 1128.00
PN-SPT towel permeability Tester is a testing instrument for towel penetration and diaper permeability developed according to the national standards GB/T 8939 and GB/T 28004. It is mainly suitable for the detection of the penetration amount of women's towels and pads. It is mainly used for the permeation performance test of disposable diapers, diapers and diaper pads (nursing pads), and is not suitable for adult mild incontinence products, such as care towels.
The amount of infiltration is an important parameter to describe the permeability of a towel. To a certain extent, it expresses the instantaneous absorption capacity of the towel in the face of raging floods. When the liquid flows down the slope, the gravity carries a certain velocity, which cleverly simulates the real situation when the human body uses the surging tide of the towel. The liquid flows quickly through the body of the towel, and the absorption capacity of the towel represents its instantaneous absorption capacity.
Permeability is an important technical parameter for the permeability of baby diapers, baby diapers, adult diapers and diapers, and diaper pads (nursing pads). It includes the amount of slippage, retracement, and leakage. The amount of slippage refers to the volume of a certain amount of test solution that is not absorbed when it flows through the surface of the inclined specimen, in ml.

Product features
1. One instrument with two functions, measuring the infiltration amount of towels and pads, and measuring the permeation performance of baby and adult diapers;
2. The angle is 10° and 30° and can be switched by plugging and removing the positioning pin, which is easy to operate.
Execution standards
GB/T 8939 、GB/T 28004、QB/T 2493
PNshar PN-SPT Sanitary napkin permeability TesterSpecifications
| LIST | VALUE |
|---|---|
| Tilt angle | 10 ° (sanitary napkins and sanitary pads)/30 ° (for baby and adult diapers) |
| Drain funnel | 250ml |
PNshar PN-SPT Sanitary napkin permeability Tester Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


PN-SPT