FANGRUI instrument NDJ-9T + DC0506N temperature control Rotational Viscometer refrigeration and heating dual purpose
FANGRUI NDJ-9T temperature control Rotational Viscometer is equipped with a Thermostatic Bath for heating and cooling, which can control the sample temperature between -5 ℃ and 100 ℃. NDJ-9T Rotational Viscometer can build 20 groups of test programs by itself, using large LCD touch screen.
FangRui-
MODERNER NDJ-5T Rotational Viscometer 1~ 100,000 mPa · s viscosity range
Login -
NIRUN CPE-42 cone-plate viscometer rotor, shear rate 3.84N
$ 658.00 -
Pingxuan NDJ-1S Digital Rotational Viscometer 0.1~ 100000cp
$ 444.00 -
HUINUO LVDV-2 Digital Rotational Viscometer 6 million mPa · s 200rpm
$ 1459.00 -
TQC DV2204 viscosity calibrated oil S60 500ml
$ 428.00
Introduction
NDJ-9T Digital Rotational Viscometer is well integrated with touch screen technology, using a fashionable and modern high technology to measure viscosity quickly, accurately and conveniently. Powerful functions, far from comparable to previous liquid crystal display viscometers.
Self-built 30 sets of test procedures help users to quickly and accurately obtain the viscosity and related data of the sample. The 5-inch super-large color touch screen can comprehensively and vividly display various parameters and Operating Conditions. It has obvious advantages such as many measurement parameters, rich display content, convenient operation, intuitive reading, high measurement accuracy, stable speed, strong anti-interference performance, and wide working Voltage. It can completely replace the imported instruments of the same type, closely following the new technological trend of domestic (CN) viscometers.
NDJ-9T Digital Rotational Viscometer can measure the absolute viscosity of Newtonian liquid or the apparent viscosity of non-Newtonian liquid.
Features
① Using ARM technology, built-in Linux system. The operation interface is simple and clear, and the viscosity test can be performed quickly and conveniently through the creation of test programs and data analysis;
② Viscosity measurement is accurate, and each range is automatically calibrated by computer, with high precision and small error;
③ Rich display content: In addition to viscosity, there are also temperature, percentage of measured value to full scale value (graphic display), range overflow alarm, automatic scan, maximum measurement range under current rotor speed combination, date, time, etc. And it can display the kinematic viscosity when the density is known, which greatly meets the different measurement requirements of users;
④ Complete functions, can measure regularly, build 30 sets of test programs, store and retrieve 30 sets of measurement data, display viscosity curves in real time, print data and curves, etc.;
⑤ Front-mounted spirit level, intuitive and convenient level adjustment;
⑥ Optional temperature probe, constant temperature bath for viscometer, constant temperature cup, printer, standard viscosity sample (standard silicone oil), etc.;
⑦ Chinese and English operating system.
Application
NDJ-9T Digital Rotational Viscometer is widely used in various fluids that need to measure viscosity and fluids under high temperature melting. Including paints, coatings, cosmetics, inks, pulp, food, oil, starch, solvent-based adhesives, latex, biochemical products, etc., as well as industries that require high-temperature melting, such as asphalt, paraffin, hot-melt adhesives, etc.
Temperature control tank introduction
The special constant temperature bath for cooling and heating dual-purpose viscometer is cooled by compressor, the maximum temperature can reach 100°C, the temperature range is -5°C~100°C, and the temperature accuracy is 0.1°C.
The machine has a 75mm round hole, which can be put into a 40ml tall beaker, and the sample to be tested is poured into the beaker, which is convenient, simple and fast to control the sample temperature.
Pictures

FangRui NDJ-9T + DC0506N Rotational viscometer setSpecifications
| LIST | VALUE |
|---|
FangRui NDJ-9T + DC0506N Rotational viscometer set Packing list
NDJ-9T Viscometer complete set x1, DC0506N Thermostat X1, manual X2, certificate of conformity X2, warranty card X2
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Fangrui NKY-25 Viscometer Temperature Controller Instructions for Use
- Viscosity, consistency and surface tension - what are these?
- Fangrui SNB-1A/NDJ-1C viscometer rotor installation specific steps
- Method for Determination of Ink Rheology: Rheological Curve Thixotropic Ring Area Method
- Viscosity measurement of coating solution by rotary viscometer
- How to install Fangrui digital Rotational Viscometer NDJ/SNB?
- How to choose a Rotational Viscometer? This is enough
- What are Newtonian and non-Newtonian fluids?
- Fangrui SNB/NDJ digital viscometer operation interface description and operation method
- Rotational viscometer data bias, these key factors to pay attention to
- ActiveJC/T 2316-2015
- ActiveSJ/T 10454-2020
- ActiveHG/T 4443-2012
- ActiveHG/T 3323-2008
- ActiveGB/T 24148.4-2009
- ActiveGB/T 21894-2008
- ActiveGB/T 17001.6-2022
- ActiveHG/T 5187-2017
- ActiveGB/T 13217.4-2020
- ActiveGB/T 12009.3-2009
- ActiveASTM D3794-2022
- ActiveJJG 1002-2005
- ActiveGB/T 21882-2008
- AbolishGB/T 11175-2002
- ActiveGB/T 1981.3-2009


NDJ-9T + DC0506N
NDJ-9T