BENTING CBGDW-100L low/high Temperature Test Chamber -20 ℃/100L
The temperature range of BENTING CBGDW-100L low/high Temperature Test Chamber is -20 ℃~ + 150 ℃, and the inner volume is 100L. CBGDW-100L adopts first-stage compression refrigeration, and the inner box size is 500 * 500 * 400mm.
BenTing-
HZAOC GDJW-225E high-low temperature cyclic Test Chamber-70-150 ℃/225L
$ 8169.00 -
ZKHS GDJW-225B High and Low Temperature Cyclic Test Chamber -20 ℃~ 150 ℃
$ 6101.00 -
HZAOC GDJW-225E high-low temperature experimental Test Chamber -70 ℃~ 150 ℃/225L
$ 8169.00 -
HZAOC GDJW-010B high-low temperature cyclic Test Chamber -30-150 ℃/1000L
$ 10957.00 -
KESIONOTS High and Low Temperature Environmental Test Chamber KS-OTS-HD800LA Temperature Control -70 ℃~ 150 ℃
$ 8748.00
Features
1. Enclosure Material: cold plate baking paint
2. Inner wall material: good mirror stainless steel plate
3. Box insulation material: glass fiber
4. Single hinged door (left hinge, right handle when facing the cabinet), equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device
5. Control panel: controller display screen, U disk interface, RS232 computer communication interface, power switch, status indicator light and sound and light alarm device
6. Unit: refrigeration unit, water tray, drain hole, condensing fan, condenser air inlet, water supply tank
7. Power distribution: IO board, machine tool transformer, ballast, intermediate relay, solid state relay, AC contactor, thermal relay, fuse, under-reverse phase relay, air switch
8. The control system automatically adjusts the energy-saving Operating Conditions of the refrigerator according to the test conditions
9. The cooling capacity of the evaporator is switched by the solenoid valve driven by the control system
BGDW series high-low temperature Test Chamber parameter pair
| model | BGDW-80L | BGDW-100L | BGDW-150L | BGDW-225L | BGDW-408L | BGDW-800L | BGDW-1000L |
| -20°C, -40°C, -70°C | -20°C, -40°C, -70°C | -20°C, -40°C; -70°C | -20°C, -40°C; -70°C | -20°C, -40°C, -70°C | -20°C, -40°C, -70°C | -20°C, -40°C, -70°C | |
| temperature range | -20°C: -20°C~+150°C -40°C: -40°C~+150°C -70°C: -70°C~+150°C | ||||||
| temperature fluctuation | ≤0.5°C (temperature fluctuation is half of the difference between the highest temperature and the lowest temperature measured at the central point) | ||||||
| temperature error | ≤±1°C (the average temperature displayed by the studio temperature controller minus the average temperature measured at the central point) | ||||||
| temperature uniformity | ≤2.0°C (The temperature uniformity is the arithmetic mean of the difference between the highest temperature and the lowest temperature measured in each test) | ||||||
| Heating time | 3°C/min (non-linear no-load) | ||||||
| cooling time | 0.75~1℃/min (non-linear no-load) | ||||||
| Relative Humidity error | ±2.5%RH | ||||||
| Humidifier power | 2.5KW | ||||||
| Way of working | The 0℃~-40℃ model adopts one-stage compression, and the -40℃~-70℃ adopts a two-element cascade refrigeration method | ||||||
| Refrigeration Compressors | Fully enclosed low noise rotary compressor | ||||||
| condenser | Air-cooled type: external fin and internal thread tube heat exchanger (water-cooled type: shell-and-tube heat exchanger) | ||||||
| Internal volume | 80L | 100L | 150L | 225L | 408L | 800L | 1000L |
| Inner box size W*H*D | 400*500*400 | 500*500*400 | 500*600*500 | 600*750*500 | 800*850*600 | 1000*1000*800 | 1000*1000*1000 |
| Outer box size W*H*D | 900*1580*950 | 1000*1580*950 | 1000*1650*1050 | 1100*1800*1050 | 1300*1900*1150 | 1500*2050*1350 | 1500*2050*1550 |
| Weight KG | 200 | 230 | 250 | 300 | 400 | 600 | 700 |
| Do not test product | It is forbidden to test products that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive substances | ||||||
BenTing CBGDW-100L Low/high Temperature Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -20~150℃ |
| Interior size | 500*500*400mm |
| Temperature fluctuation | ≤0.5℃ |
| temperature error | ≤ +/- 1 ℃ (the average temperature of the displayed value of the studio temperature Controller minus the measured average temperature at the center point) |
| Temperature Uniformity | ≤2.0℃ |
| Heating rate | 3℃/min |
| Cooling rate | 0.75~ 1 ℃/min (non-linear no-load) |
| Humidity Deviation | ±2.5%RH |
| Humidifier power | 2.5KW |
| Operating Mode | The 0 ℃~ -40 ℃ model adopts one-stage compression |
| Refrigeration system | Fully enclosed low noise rotary compressor |
| Refrigeration system | Air-cooled type: external fin internal thread tube heat exchanger (water-cooled type: shell and tube heat exchanger) |
| Interior Volume | 100L |
| Dimensions | 1000*1580*950mm |
| Weight | 230kg |
| Prohibit testing products | Prohibition of testing of products that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive substances |
BenTing CBGDW-100L Low/high Temperature Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Low/high Temperature Test Chamber for high-low temperature resistance test of insulating potting materials
- Low/high Temperature Test Chamber for automobile bunker oil pump
- High-low temperature resistance test of electronic chip
- Low/high Temperature Test Chamber for potentiometers
- Low/high Temperature Test Chamber test magnesium alloy high-low temperature performance
- Low/high Temperature Test Chamber for high-low temperature performance test of pharmaceuticals
- Application of low/high Temperature Test Chamber in high-low temperature resistance test of electrical coatings
- Low/high Temperature Test Chamber for testing high-low temperature resistance of plastic profiles
- High-low Temperature Test Chamber, principle-application-operation-selection-problem
- What factors affect the uniformity of the high-low Temperature Test Chamber?
- ActiveGB/T 2424.7-2024
- ActiveJB/T 4278.8-2011
- ActiveJG/T 25-2017
- ActiveGB/T 9979-2005
- ActiveGB/T 23711.2-2019
- ActiveGB/T 10590-2006
- ActiveGB/T 33861-2017
- ActiveGB/T 10592-2023
- ActiveGB/T 2423.63-2019
- Active 10590-2006
- ActiveGB/T 41166-2021
- ActiveGB/T 25261-2018
- ActiveGB/T 2423.102-2008
- AbolishGB/T 2423.34-2005
- ActiveHG/T 5175-2017
- ActiveGB/T 10589-2008
- ReplacedGB/T 10592-2008
- ActiveGB/T 2423.1-2008
- AbolishGB/T 11175-2002
- ActiveHG/T 2003-1991


CBGDW-100L