      BenTing CBGDW-225L Low/high Temperature Test Chamber

      BENTING CBGDW-225L low/high Temperature Test Chamber -70 ℃/225L

      BENTING CBGDW-225L is a low/high Temperature Test Chamber with an inner volume of 225L, the inner box size is 600 * 750 * 500mm, fiberglass insulation material, CBGDW-225L Temperature range -70 ℃~ 150 ℃, using binary cascade refrigeration method.

      Brand
      SKU: NB028780
      China BenTing
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • BenTing CBGDW-225L Low/high Temperature Test ChamberOverview

        • Specifications
        • Comments
        • FAQs
        CBGDW-225L
        Low/high Temperature Test Chamber

        Features

        1. Enclosure Material: cold plate baking paint

        2. Inner wall material: good mirror stainless steel plate

        3. Box insulation material: glass fiber

        4. Single hinged door (left hinge, right handle when facing the cabinet), equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device

        5. Control panel: controller display screen, U disk interface, RS232 computer communication interface, power switch, status indicator light and sound and light alarm device

        6. Unit: refrigeration unit, water tray, drain hole, condensing fan, condenser air inlet, water supply tank

        7. Power distribution: IO board, machine tool transformer, ballast, intermediate relay, solid state relay, AC contactor, thermal relay, fuse, under-reverse phase relay, air switch

        8. The control system automatically adjusts the energy-saving Operating Conditions of the refrigerator according to the test conditions

        9. The cooling capacity of the evaporator is switched by the solenoid valve driven by the control system

        BGDW series high-low temperature Test Chamber parameter pair

        modelBGDW-80LBGDW-100LBGDW-150LBGDW-225LBGDW-408LBGDW-800LBGDW-1000L
        -20°C, -40°C, -70°C-20°C, -40°C, -70°C-20°C, -40°C; -70°C-20°C, -40°C; -70°C-20°C, -40°C, -70°C-20°C, -40°C, -70°C-20°C, -40°C, -70°C
        temperature range-20°C: -20°C~+150°C -40°C: -40°C~+150°C -70°C: -70°C~+150°C
        temperature fluctuation≤0.5°C (temperature fluctuation is half of the difference between the highest temperature and the lowest temperature measured at the central point)
        temperature error≤±1°C (the average temperature displayed by the studio temperature controller minus the average temperature measured at the central point)
        temperature uniformity≤2.0°C (The temperature uniformity is the arithmetic mean of the difference between the highest temperature and the lowest temperature measured in each test)
        Heating time3°C/min (non-linear no-load)
        cooling time0.75~1℃/min (non-linear no-load)
        Relative Humidity error±2.5%RH
        Humidifier power2.5KW
        Way of workingThe 0℃~-40℃ model adopts one-stage compression, and the -40℃~-70℃ adopts a two-element cascade refrigeration method
        Refrigeration CompressorsFully enclosed low noise rotary compressor
        condenserAir-cooled type: external fin and internal thread tube heat exchanger (water-cooled type: shell-and-tube heat exchanger)
        Internal volume80L100L150L225L408L800L1000L
        Inner box size W*H*D400*500*400500*500*400500*600*500600*750*500800*850*6001000*1000*8001000*1000*1000
        Outer box size W*H*D900*1580*9501000*1580*9501000*1650*10501100*1800*10501300*1900*11501500*2050*13501500*2050*1550
        Weight KG200230250300400600700
        Do not test productIt is forbidden to test products that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive substances


        VS

        BenTing CBGDW-225L Low/high Temperature Test ChamberSpecifications

        LIST VALUE
        Temperature range -70~150℃
        Interior size 600*750*500mm
        Temperature fluctuation ≤0.5℃
        temperature error ≤ +/- 1 ℃ (the average temperature of the displayed value of the studio temperature Controller minus the measured average temperature at the center point)
        Temperature Uniformity ≤2.0℃
        Heating rate 3℃/min
        Cooling rate 0.75~ 1 ℃/min (non-linear no-load)
        Humidity Deviation ±2.5%RH
        Humidifier power 2.5KW
        Operating Mode -40 ℃~ -70 ℃ adopts binary cascade refrigeration method
        Refrigeration system Fully enclosed low noise rotary compressor
        Refrigeration system Air-cooled type: external fin internal thread tube heat exchanger (water-cooled type: shell and tube heat exchanger)
        Interior Volume 225L
        Dimensions 1100*1800*1050mm
        Weight 300kg
        Prohibit testing products Prohibition of testing of products that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive substances

        BenTing CBGDW-225L Low/high Temperature Test Chamber Packing list

        complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is this low/high temperature test chamber HG/T2003 compliant?
        [A]
        This low/high temperature test chamber is suitable for HG/T2003. Please consult customer service for detailed application definition