BENTING CBGDW-800L low/high Temperature Test Chamber -40 ℃/800L
BENTING low/high Temperature Test Chamber CBGDW-800L temperature control as low as minus 40 ℃, Temperature fluctuation ≤ 0.5 ℃, is 800L volume low/high Temperature Test Chamber, CBGDW-800L adopts binary cascade refrigeration method, fiberglass insulation material.
BenTing-
ZKHS GDW-500B Temperature Cycling Test Chamber -40 ℃~ 150 ℃
$ 7844.00 -
HUDA material rapid temperature change Test Chamber QD-E708-512K40-X5
$ 11061.00 -
HUDA rapid temperature change Test Chamber QD-E708-150K40-X10
$ 14052.00 -
HZAOC GDJW-150A Temperature Cycling Test Chamber -20 ℃~ 150 ℃/150L
$ 6258.00 -
ZKHS GDJW-225B High and Low Temperature Cyclic Test Chamber -20 ℃~ 150 ℃
$ 6056.00
Features
1. Enclosure Material: cold plate baking paint
2. Inner wall material: good mirror stainless steel plate
3. Box insulation material: glass fiber
4. Single hinged door (left hinge, right handle when facing the cabinet), equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device
5. Control panel: controller display screen, U disk interface, RS232 computer communication interface, power switch, status indicator light and sound and light alarm device
6. Unit: refrigeration unit, water tray, drain hole, condensing fan, condenser air inlet, water supply tank
7. Power distribution: IO board, machine tool transformer, ballast, intermediate relay, solid state relay, AC contactor, thermal relay, fuse, under-reverse phase relay, air switch
8. The control system automatically adjusts the energy-saving Operating Conditions of the refrigerator according to the test conditions
9. The cooling capacity of the evaporator is switched by the solenoid valve driven by the control system
Applications
It is used for the reliability test of high, low temperature, constant humidity and heat of industrial products. For components and materials of related products such as electronics, automobiles and motorcycles, aerospace, ship weapons, colleges and universities, scientific research units, etc., test their various performance indicators under the conditions of high-low temperature cycles and constant humidity and heat changes. The product has a wide range of temperature control, and its performance indicators have reached the technical conditions of the national standard GB10592-89 high-low Temperature Test Chamber, which is suitable for environmental testing of electrical and electronic products according to GB2423.1, GB2423.2, and GB2423.3. Test A: low temperature Test method Test B: High temperature test method C: Constant damp heat test method "Carry out low temperature, high temperature and constant damp heat tests on the product. The products comply with GB2423.1, GB2423.2, GJB150.3, GJB150.4, IEC, MIL standards.
BGDW series high-low temperature Test Chamber parameter comparison table
| model | volume | Inner box size | Carton size |
| BGDW-80L | 80L | 400*500*400mm | 900*1580* 950mm |
| BGDW-100L | 100L | 500*500* 400mm | 1000*1580* 950mm |
| BGDW-150L | 150L | 500*600* 500mm | 1000*1650* 1050mm |
| BGDW-225L | 225L | 600*750* 500mm | 1100*1800* 1050mm |
| BGDW-408L | 408L | 800*850* 600mm | 1300*1900* 1150mm |
| BGDW-800L | 800L | 1000*1000* 800mm | 1500*2050* 1350mm |
| BGDW-1000L | 1000L | 1000*1000* 1000mm | 1500*2050* 1550mm |
| Other parameters | |||
| temperature range | -20°C: -20°C~+150°C; -40°C: -40°C~+150°C; -70°C: -70°C~+150°C | ||
| temperature error | ≤±1℃ | ||
| temperature fluctuation | ≤0.5℃ | ||
| temperature uniformity | ≤2.0℃ | ||
| Heating time | 3°C/min (non-linear no-load) | ||
| cooling time | 0.75~1℃/min (non-linear no-load) | ||
| Relative Humidity error | ±2.5%RH | ||
| Humidifier power | 2.5KW | ||
| Way of working | The 0℃~-40℃ model adopts one-stage compression, and the -40℃~-70℃ adopts a two-element cascade refrigeration method | ||
| Refrigeration Compressors | Fully enclosed low noise rotary compressor | ||
| condenser | Air-cooled type: external fin and internal thread tube heat exchanger (water-cooled type: shell-and-tube heat exchanger) | ||
BenTing CBGDW-800L Low/high Temperature Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -40~150℃ |
| Interior size | 1000*1000*800mm |
| Temperature fluctuation | ≤0.5℃ |
| temperature error | ≤ +/- 1 ℃ (the average temperature of the displayed value of the studio temperature Controller minus the measured average temperature at the center point) |
| Temperature Uniformity | ≤2.0℃ |
| Heating rate | 3℃/min |
| Cooling rate | 0.75~ 1 ℃/min (non-linear no-load) |
| Humidity Deviation | ±2.5%RH |
| Humidifier power | 2.5KW |
| Operating Mode | -40 ℃~ -70 ℃ adopts binary cascade refrigeration method |
| Refrigeration system | Fully enclosed low noise rotary compressor |
| Refrigeration system | Air-cooled type: external fin internal thread tube heat exchanger (water-cooled type: shell and tube heat exchanger) |
| Interior Volume | 800L |
| Dimensions | 1500*2050*1350mm |
| Weight | 600kg |
| Prohibit testing products | Prohibition of testing of products that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive substances |
BenTing CBGDW-800L Low/high Temperature Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 2424.7-2024
- ActiveJB/T 4278.8-2011
- ActiveGB/T 9979-2005
- ActiveGB/T 39933-2021
- ActiveGB/T 10590-2006
- ActiveGB/T 33861-2017
- ActiveGB/T 10592-2023
- ActiveGB/T 2423.63-2019
- Active 10590-2006
- ActiveGB/T 41166-2021
- ActiveGB/T 2423.102-2008
- AbolishGB/T 2423.34-2005
- AbolishGB/T 2423.25-2008
- ActiveGB/T 8013.1-2018
- ActiveHG/T 5164-2017
- ActiveGB/T 10589-2008
- ReplacedGB/T 10592-2008
- ActiveGB/T 2423.1-2008
- ActiveHG/T 2003-1991


CBGDW-800L