BENTING CBGDW-1000L low/high Temperature Test Chamber -20 ℃/1000L
BENTING low/high Temperature Test Chamber CBGDW-1000L adopts fiberglass insulation material, Temperature range -20 ℃~ + 150 ℃, fluctuation ≤ 0.5 ℃, CBGDW-1000L is a high-low temperature environment Test Chamber with an inner volume of 1000L.
BenTing-
YIHENG BPHJ-250C high-low temperature (alternating) Test Chamber -60 ℃~ 130 ℃/250L
$ 8151.00 -
HZAOC GDJW-100A Temperature Cycling Test Chamber -20 ℃~ 150 ℃/100L
$ 5636.00 -
BOZHEN GDW4025 low/high Temperature Test Chamber -40~130 ℃/250L
$ 4997.00 -
KESIONOTS programmable low/high temperature test chamber KS-OTS-HD150LC temperature control -40 ℃~ 150 ℃
$ 5232.00 -
ZKHS GDW-010B Temperature Cycling Test Chamber -20 ℃~ 150 ℃
$ 9522.00
Features
1. Enclosure Material: cold plate baking paint
2. Inner wall material: good mirror stainless steel plate
3. Box insulation material: glass fiber
4. Single hinged door (left hinge, right handle when facing the cabinet), equipped with observation window, lighting, window frame/door frame anti-condensation electric heating device
5. Control panel: controller display screen, U disk interface, RS232 computer communication interface, power switch, status indicator light and sound and light alarm device
6. Unit: refrigeration unit, water tray, drain hole, condensing fan, condenser air inlet, water supply tank
7. Power distribution: IO board, machine tool transformer, ballast, intermediate relay, solid state relay, AC contactor, thermal relay, fuse, under-reverse phase relay, air switch
8. The control system automatically adjusts the energy-saving Operating Conditions of the refrigerator according to the test conditions
9. The cooling capacity of the evaporator is switched by the solenoid valve driven by the control system
BGDW series high-low temperature Test Chamber parameter pair
| model | BGDW-80L | BGDW-100L | BGDW-150L | BGDW-225L | BGDW-408L | BGDW-800L | BGDW-1000L |
| -20°C, -40°C, -70°C | -20°C, -40°C, -70°C | -20°C, -40°C; -70°C | -20°C, -40°C; -70°C | -20°C, -40°C, -70°C | -20°C, -40°C, -70°C | -20°C, -40°C, -70°C | |
| temperature range | -20°C: -20°C~+150°C -40°C: -40°C~+150°C -70°C: -70°C~+150°C | ||||||
| temperature fluctuation | ≤0.5°C (temperature fluctuation is half of the difference between the highest temperature and the lowest temperature measured at the central point) | ||||||
| temperature error | ≤±1°C (the average temperature displayed by the studio temperature controller minus the average temperature measured at the central point) | ||||||
| temperature uniformity | ≤2.0°C (The temperature uniformity is the arithmetic mean of the difference between the highest temperature and the lowest temperature measured in each test) | ||||||
| Heating time | 3°C/min (non-linear no-load) | ||||||
| cooling time | 0.75~1℃/min (non-linear no-load) | ||||||
| Relative Humidity error | ±2.5%RH | ||||||
| Humidifier power | 2.5KW | ||||||
| Way of working | The 0℃~-40℃ model adopts one-stage compression, and the -40℃~-70℃ adopts a two-element cascade refrigeration method | ||||||
| Refrigeration Compressors | Fully enclosed low noise rotary compressor | ||||||
| condenser | Air-cooled type: external fin and internal thread tube heat exchanger (water-cooled type: shell-and-tube heat exchanger) | ||||||
| Internal volume | 80L | 100L | 150L | 225L | 408L | 800L | 1000L |
| Inner box size W*H*D | 400*500*400 | 500*500*400 | 500*600*500 | 600*750*500 | 800*850*600 | 1000*1000*800 | 1000*1000*1000 |
| Outer box size W*H*D | 900*1580*950 | 1000*1580*950 | 1000*1650*1050 | 1100*1800*1050 | 1300*1900*1150 | 1500*2050*1350 | 1500*2050*1550 |
| Weight KG | 200 | 230 | 250 | 300 | 400 | 600 | 700 |
| Do not test product | It is forbidden to test products that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive substances | ||||||
BenTing CBGDW-1000L Low/high Temperature Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -20~150℃ |
| Interior size | 1000*1000*1000mm |
| Temperature fluctuation | ≤0.5℃ |
| temperature error | ≤ +/- 1 ℃ (the average temperature of the displayed value of the studio temperature Controller minus the measured average temperature at the center point) |
| Temperature Uniformity | ≤2.0℃ |
| Heating rate | 3℃/min |
| Cooling rate | 0.75~ 1 ℃/min (non-linear no-load) |
| Humidity Deviation | ±2.5%RH |
| Humidifier power | 2.5KW |
| Operating Mode | The 0 ℃~ -40 ℃ model adopts one-stage compression |
| Refrigeration system | Fully enclosed low noise rotary compressor |
| Refrigeration system | Air-cooled type: external fin internal thread tube heat exchanger (water-cooled type: shell and tube heat exchanger) |
| Interior Volume | 1000L |
| Dimensions | 1500*2050*1550mm |
| Weight | 700kg |
| Prohibit testing products | Prohibition of testing of products that may produce flammable, explosive, volatile, highly toxic, corrosive and radioactive substances |
BenTing CBGDW-1000L Low/high Temperature Test Chamber Packing list
complete-built unit X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 2424.7-2024
- ActiveJB/T 4278.8-2011
- ActiveJG/T 25-2017
- ActiveGB/T 9979-2005
- ActiveGB/T 23711.2-2019
- ActiveGB/T 10590-2006
- ActiveGB/T 33861-2017
- ActiveGB/T 10592-2023
- ActiveGB/T 2423.63-2019
- ActiveGB/T 32710.11-2016
- Active 10590-2006
- ActiveGB/T 41166-2021
- ActiveGB/T 25261-2018
- ActiveGB/T 2423.102-2008
- AbolishGB/T 2423.34-2005
- ActiveHG/T 5175-2017
- ActiveGB/T 10589-2008
- ReplacedGB/T 10592-2008
- ActiveGB/T 2423.1-2008
- AbolishGB/T 11175-2002


CBGDW-1000L