JENCO 6360 Portable Water Quality Analyzer Determination of pH/ORP/conductivity/salinity /TDS/temperature
-2~ 16/0.01 pH, -1500~1500/1mV, 0~80ppt, 0~200.0mS/0.01µS, manual/automatic temperature compensation -5.0~75.0 ℃, RS-232C
JENCO-
YUEFENG SZ81111 Chlorine dioxide analyzer, chlorine dioxide concentration analysis 0~ 5.0mg/L
$ 343.00 -
JINGQI WD8217 boron Tester
$ 481.00 -
YUEFENG SZ8128 multiparameter STIP-scan to measure 12 kinds of water quality parameters
$ 1019.00 -
LEICI sodium ion electrode calibrated solution, suitable for sodium ion composite electrode
$ 106.00 -
TONGAO TR-701H Water Quality Nitrate Nitrogen Tester
$ 786.00
Features
1. Can measure acidity and alkalinity (pH) redox (ORP) conductivity (EC) salinity (Salt) TDS temperature
2. Microcomputer design, with RS-232C communication interface (can be converted to USB)
3. Automatic/manual temperature compensation
4. Automatic shutdown function
5. Can be connected to 2-ring and 4-ring conductivity electrodes
6. Fifty sets of test data memory storage
7. AC and DC power supply

Jenco 6360 portable multi-parameter Water Quality Analyzer standard configuration
| 6360 | Host, four-ring electrode (K=0.475cm-1), 6005P, AC power converter (output: DC9V) or 6 1.5 volt 7# batteries, suitcase, software CD |
Optional for Jenco 6360 portable multi-parameter Water Quality Analyzer
| 600S-ORP/600L-ORP | Plastic/glass ORP composite electrode (oxidation-reduction potential measurement) |
| GB700E | Refillable glass pH combination electrode (routine measurement |
| GB710E | Composite electrode (glass), sticky or greasy objects, strong acids and alkalis |
| 600P | Composite plastic shell pH composite electrode (no temperature compensation, routine measurement) |
| 600C | Pure water glass pH composite electrode (pure water, ultrapure water measurement) |
| 6230AST | Stainless steel temperature probe |
JENCO 6360 Portable Water Quality AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| pH Measurement Range | -2.00~16.00pH |
| pH resolution | 0.01pH |
| pH measurement Accuracy | +/- 0.1% pH +/- 1 word |
| ORP Measurement Range | ± 2000.0mV |
| ORP resolution | 1mV |
| ORP Accuracy | +/- 1% +/- 1 word |
| TDS range | 0.00ppm~200.0ppt |
| TDS resolution | 0.01/0.1 |
| TDS measurement Accuracy | ± 0.5%FS |
| Salinity range | 0.0~80.0ppt |
| Salinity resolution | 0.1 |
| Salinity measurement Accuracy | ± 1%FS |
| Temperature Measurement Range | -5.0~100.0℃ |
| Temperature Resolution | 0.1℃ |
| Temperature measurement Accuracy | +/- 0.3 ℃ +/- 1 word |
| pH correction solution type | 4.0, 6.86, 9.18/4.0, 7.0, 10.0 two groups optional, 2 points automatic correction |
| EC Temperature Compensation Range | Automatic -5.0~100.0 ℃ |
| temperature coefficient | 0.00~4.00% adjustable, default 1.9% |
| TDS conversion factor | 0.30~1.00 adjustable, default value 0.65 |
| Conductivity calibrated point | Multi-point manual correction |
| Salinity correction | Multi-point manual correction (China's standard seawater salinity is 5ppt, 20ppt, 30ppt, 35ppt and 40ppt) |
| Data storage | 50 sets |
| Communication interface | RS-232C (to USB) |
| Power | AC power converter (output: DC9V) or 6 1.5 volt 7 #batteries |
| Ambient Temperature | 0~50℃ |
| Dimensions | 241*86*72mm |
| Weight | Approx. 470g (without battery) |
| Shop Accessories | Plastic case/Glass ORP composite electrode (Oxidation-reduction potential measurement), Fillable Glass pH composite electrode (conventional measurement), composite electrode (Glass), viscous or greasy objects, strong acid and alkali |
| Shop Accessories | Stainless steel temperature probe, plastic shell pH composite electrode (conventional measurement), pure water Glass pH composite electrode (pure water, ultrapure water measurement), Glass pH composite electrode (70~100.0 ℃ medium, organic solvent, protein medium measurement) |
| Working Relative Humidity | <90% |
JENCO 6360 Portable Water Quality Analyzer Packing list
Host X1, Conductivity detector (101C) X1, 6005P electrode X1, AC voltage regulator X1, battery X1, correction liquid X1, software X1, suitcase X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use


6360