FANGRUI STM-2T Stormer Viscometer with PT100 temperature probe
Support 30 sets of test procedures, using 5-inch large color touch screen, measuring range 40.2~ 141.0KU, 32~ 1099g, 27~ 5274cP, in line with ASTM D562 and GB9296 standards.
FangRui-
NIRUN STM-2T Digital Stormer Viscometer Coating paints inks
$ 1024.00 -
STM-IV Digital Stormer Viscometer YONGLIDA 40.2KU~ 141.0KU Viscosity Range
$ 755.00 -
JFL STM-IV Stormer Viscometer
$ 762.00 -
JINGKELIAN QNZ Stormer Viscometer measurement viscosity KU value ASTM-D562 standard and GB9269-88 standard
$ 417.00 -
MODERNER STM-VII Digital Stormer Viscometer
Login
STM-2T Stormer viscometer is an upgraded product of STM-IV and STM-2, fully integrated with touch screen technology, using a fashionable and modern high technology to quickly, accurately and conveniently measure the viscosity of paint, ink and coating . Powerful and highly intelligent, it is far from comparable to previous liquid crystal display viscometers.
Self-built 30 sets of test procedures help users to quickly and accurately obtain the viscosity and related data of the sample. The 5-inch super-large color touch screen can comprehensively and vividly display various parameters and Operating Conditions. It has obvious advantages such as many measurement parameters, rich display content, convenient operation, intuitive reading, high measurement accuracy, stable speed, strong anti-interference performance, and wide working Voltage.
main feature
Using ARM technology and built-in Linux system: the operation interface is simple and clear, and the viscosity test can be performed quickly and conveniently through the creation of test programs and data analysis;
Accurate viscosity measurement: automatic calibration by computer, high precision and small error;
Rich display content: In addition to displaying the three commonly used parameters of KU, g, and cp, there are also temperature, the percentage of the measured value in the full range value (graphic display), viscosity curve, range overflow alarm, measurement time, date, etc.;
Timing measurement function: very practical. The paints, inks, and coatings we measure are typical non-Newtonian liquids, and their viscosity is not only related to temperature (the viscosity decreases as the temperature rises), but also related to the length of the measurement time. Paints, inks and coatings exhibit the characteristics of shear thinning. The longer the measurement time, the lower the viscosity. If the viscosity of the same type of samples is to be comparable, the measurement time needs to be the same;
Self-built 30 sets of test programs: can be compiled by oneself and quickly called;
Access 30 sets of measurement data and curves; save in the viscometer, the data includes sample name, KU, g, CP value, date, etc.;
Real-time display of viscosity curve: can be adjusted at any time on the touch screen;
Can be connected to a micro-printer and a computer: there are two interfaces respectively, the serial port is connected to the computer, and the parallel port is connected to the printer;
Front level meter: The rotor is put into the sample vertically, which is very important for the accuracy of the measurement data. By observing the front level meter, adjusting the three level feet of the base can easily adjust the water bubble of the level meter to the middle position (there is no level adjustment device in the domestic (CN) market at present);
Abundant optional accessories: temperature probe, constant temperature bath for viscometer, constant temperature cup, printer, standard viscosity samples, etc.;
Chinese and English operating system.
STM-2T is widely used in measuring the viscosity of paints, inks, coatings or other industries where the KU value is used to express the viscosity. It complies with international standards ASTM D562 and GB9296 and other relevant national standards.
FangRui STM-2T+PT100 Stormer ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display | digital display |
| Measuring range | 40.2 ~ 141.0KU, 32 ~ 1099g, 27 ~ 5274cP |
| Unit display | KU / g / cP |
| Swirl/spin speed | 200rpm |
| Sexual repeability | ±0.5%F.S |
| Accuracy | ±1% |
| Power | 110V/60Hz 或 220V/50Hz |
| Data Interface | Can be connected to a computer (computer optional) |
| Applicable standard | GB/T 9269、ASTM D 562 |
| Lifting method | Knob lift |
| Dimensions | 300*300*450mm |
| Container size | 1pint、0.5pint |
| Timer | From 1 minute - 99 hours, standard |
| Thermostatic parts | PT100 temperature probe |
| Self-built measurement program | Can save 30 sets (including sample name, measurement time, date, etc.) |
| data storage | Can save 30 sets of data (including KU, g, cP, time, Linear dispersion, etc.) |
| Viscosity Linear dispersion | Viscosity Linear dispersion in real time |
| Printer output | Data, Linear dispersion printable (printer optional) |
| Thermostatic parts | Options (including various Viscometer Thermostats, thermostatic cups,) |
| Speed Accuracy | ±0.1rpm |
FangRui STM-2T+PT100 Stormer Viscometer Packing list
Viscometer host x1, PT100 temperature probe x1, KU rotor x1, triangular base x1, column x1, sample container cup x1, power adapter x1, instrument aluminum box gold foil x1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Fangresstomer viscometer installation operation demonstration video
- Installation and use of Fangrui Rotational Viscometer No. 0 rotor
- Measuring methods of paints viscosity
- How to ensure accurate Stormer Viscometer measurements? with calibration method
- Stormer Viscometer (KU): Accurate measurement and multi-domain applications
- What is a drop ball viscometer?
- The basic knowledge of viscometer is enough to read this article
- Viscosity of paint rheology
- Viscosity, consistency and surface tension - what are these?
- How to choose the right powder coating synthetic resin?


STM-2T+PT100
STM-2T