DADI CHD-4030 Thermostatic Bath -40 ℃/30L
CHD-4030 Low temperature Thermostatic Bath Temperature range -40~95 ℃, Temperature Fluctuation +/- 0.1 ℃, Temperature controller Microcomputer temperature controller, working tank volume 30L, opening size 400 * 160mm, working bath depth 250mm, working tank material stainless steel
DaDi-
HDC0506N (W) Horizontal Thermostat Temperature range -5~ 100 ℃
$ 719.00 -
FANGRUI HDC2006 Constant Temperature Circulating Bath, temperature range -20~100 ℃
$ 845.00 -
CH1530 LABOratory Thermostat 30L Temperature range RT + 10~150 ℃
$ 665.00 -
CHANGZHOU GUOHUA HH-42 digital thermostatic stirring circulating Water Tank
$ 217.00 -
SANFA DKB-501A high-precision super constant temperature Water Bath + 5 - 100 ℃/ +/- 0.2 ℃
$ 599.00
use
The super thermostat is suitable for precision constant temperature in biological, chemical, physical, plant, chemical and other scientific research.
structure
The chassis of this product is made of good cold-rolled plate spraying, the inner liner is made of good stainless steel, and the insulation is foamed with foaming agent, which has good thermal insulation effect, strong and reliable, and the whole machine is controlled by a microcomputer temperature controller, which has the advantages of high temperature control accuracy.
CHD series models
| Model | Temperature range | Temperature fluctuations | The volume of the tank is mm³ Length× width × depth | Groove opening mm² | Pump flow | Heating power |
| CHD-0515 | -5~95℃ | ±0.05℃ | 300×250×200 | 250×160 | 6L/min | 800W |
| CHD-1015 | -10~95℃ | ±0.05℃ | ||||
| CHD-2015 | -20~95℃ | ±0.05℃ | ||||
| CHD-3015 | -30~95℃ | ±0.1℃ | ||||
| CHD-4015 | -40~95℃ | ±0.1℃ | ||||
| CHD-0506 | -5~95℃ | ±0.05℃ | 250×200×150 | 200×140 | 600W | |
| CHD-1006 | -10~95℃ | ±0.05℃ | ||||
| CHD-2006 | -20~95℃ | ±0.05℃ | ||||
| CHD-3006 | -30~95℃ | ±0.1℃ | ||||
| CHD-4006 | -40~95℃ | ±0.1℃ | ||||
| CHD-0530 | -5~95℃ | ±0.05℃ | 300×400×250 | 400×160 | 1500W | |
| CHD-1030 | -10~95℃ | ±0.05℃ | ||||
| CHD-2030 | -20~95℃ | ±0.05℃ | ||||
| CHD-3030 | -30~95℃ | ±0.1℃ | ||||
| CHD-4030 | -40~95℃ | ±0.1℃ | ||||
| CHD05120 | -5~95℃ | ±0.05℃ | 450×670×400 | 420×640 | 30 | 7500W |
| CHD20120 | -20~95℃ | |||||
| CHD0550 | -5~65℃ | ±0.30℃ | 400×450×280 | 350×410 | 15 | 1000W |
How to use:
1. Read the instruction manual carefully and be familiar with the name of the instrument before use.
2. Add the refrigeration solution before use, and the solution is generally added to the overflow port until the overflow is overflowed.
3. Turn on the power switch to "ON", set the temperature required for the experiment on the thermostat, in order to make the temperature in the working room uniform, you can turn on the Circulating Chiller switch to make the water circulate inside.
4. Normal use: the refrigeration switch should be played in the "dual control" position, the intelligent thermostat CL should be set at 0-0.5 °C, the P value should be set according to the difference between the actual environment and the experimental temperature, if the actual ambient temperature is greater than the actual temperature, the P value should be set between 30-50, if the actual environment is less than the experimental temperature, the P value should be adjusted between 10-30, and the CT should be set between 240-300 seconds. If the temperature control accuracy is required to be high≤± when 0.2 °C, you can turn the refrigeration switch to the "direct cooling" position, at this time the compressor has been working, refer to the temperature controller manual, start the self-tuning function, set the actual temperature, press and hold "∨", press and hold for 20 seconds, and the RUN light will flash. After the machine works for a period of time, the RUN light turns to steady on and enters the normal constant temperature state.
Precautions
1. The refrigeration medium of this machine is better to use distilled water, alcohol, etc., and it is strictly forbidden to use corrosive solutions such as sodium chloride.
2. The water pump of this product can be used externally, and the horizontal position of the external Water Bath should be higher than that of the super constant temperature Water Bath, and the water inlet pipe of the external Water Bath should be placed at the bottom, and the water outlet pipe should be on the top, as a high hydraulic limit standard, and the external Water Bath should be added with a certain amount of water when in use, and then connected to the connecting pipe to open the water pump to work, otherwise the liquid in the super temperature control tube alone will be evacuated by the external Water Bath, causing the heating pipe to be exposed to the water surface and damaged.
3. Pay attention to cleanliness when using to prevent the Water Bath liquid from splashing into the controller, causing damage to the control line or leakage.
DaDi CHD-4030 Thermostatic BathSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -40~95℃ |
| Temperature Fluctuation | ±0.1℃ |
| Temperature control mode | Microcomputer temperature Controller |
| Tank Volume | 30L |
| Tank opening Dimensions | 400*160mm |
| Tank Depth | 250mm |
| Tank Material | stainless steel |
| Tank Size | 300*400*250mm |
| refrigeration method | Compressor refrigeration |
| Flow rate of pump | 6L/min |
| Heating power | 1500W |
DaDi CHD-4030 Thermostatic Bath Packing list
whole machine X1, operation manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


CHD-4030