JENCO 9250M is a dissolved oxygen range of 0.00~50.00ppm, dissolved oxygen resolution and accuracy are 0.01ppm, +/- 0.2% FS a portable Dissolved Oxygen Meter, 9250M portable Dissolved Oxygen Meter can be measured dissolved oxygen, air saturation, temperature.
JENCO-
TONGAO TR-205H Total Chromium (Chromium Ion) Tester
$ 786.00 -
Bante903-CN Precision pH/Dissolved Oxygen Meter water quality monitor
$ 563.00 -
HANNA HI97751 Sulfate Portable Photometer
$ 540.00 -
DDKSIC PD100 desktop pH, Dissolved Oxygen Meter pH/mV (ORP electrode optional)/DO/℃
$ 783.00 -
Bante820 economical portable Dissolved Oxygen Meter with DO100 dissolved Oxygen electrode
$ 392.00
Introduction to JENCO 9250M Portable Dissolved Oxygen Meter
1) Can measure dissolved oxygen, air saturation and temperature
2) Correction value power-off memory function
3) Automatic temperature compensation
4) Manual pressure and salinity compensation
5) Low battery warning
6) RS-232C communication interface
7) 50 sets of test data storage
8) AC and DC power supply
9) Imported polarographic dissolved oxygen electrode

Portable Dissolved Oxygen Meter standard configuration | |||
| 9250M | Host, LD-900-10 electrode, LD-900-3A electrode membrane head, 007N universal bracket, AC power converter (output: DC9V), 6 1.5 volt 7# batteries, software CD, suitcase | ||
JENCO 9250M Portable Dissolved Oxygen MeterSpecifications
| LIST | VALUE |
|---|---|
| DO Measurement Range | 0.00~50.00ppm |
| DOS resolution | 0.01ppm |
| DO measurement Accuracy | ± 0.2% FS |
| Air saturation range | 0.0~500.0% |
| Air saturation resolution | 0.1% |
| Accuracy of air saturation | ± 0.2% FS |
| Temperature Measurement Range | -6.0~46.0℃ |
| Temperature Resolution | 0.1℃ |
| Temperature measurement Accuracy | ±0.3℃ |
| Pressure compensation range | 600 to 1100mBar adjustable, default value is 1013mBar |
| Salinity compensation range | 0.0~40.0ppt adjustable, the default value is 0.0ppt |
| Electrode type | polarography |
| calibration data store | Yes. |
| Measured value storage | There are 50 groups |
| Communication interface | RS232,USB |
| Automatic temperature compensation | Yes. |
| Power | AC Power (220V) or 6 5 #batteries (1.5V) |
| Ambient Temperature | 0~50℃ |
| Weight | 410G (without battery) |
| Working Relative Humidity | <90% |
| size | 241mm x 86mm x72mm |
JENCO 9250M Portable Dissolved Oxygen Meter Packing list
Host X1, LD-900-10 electrode X1, LD-900-3A electrode film head X1, AC voltage regulator X1, battery X1, software X1, suitcase X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveHJ 925-2017
- Active 096-2007
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveHJ 2515-2012


9250M