Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> JENCO> JENCO 3020M Water quality Measurement Instrument

      JENCO 3020M portable Water Quality Meter conductivity /TDS/salinity/temperature measurement

      0~200mS/0.01µS, salinity display 0~80ppt, TDS (can be equipped with 4-ring and 2-ring electrodes)

      Brand
      SKU: NB002909
      United States JENCO
      Model
      VS
      Genuinegoods
      • JENCO 3020M Water quality Measurement InstrumentOverview

      • Specifications
      • Comments
      • FAQs
      3020M
      Water quality Measurement Instrument
      • JENCO 3020M portable Water Quality Meter conductivity /TDS/salinity/temperature measurement
      • JENCO 3020M portable Water Quality Meter conductivity /TDS/salinity/temperature measurement Figure 1
      • JENCO 3020M portable Water Quality Meter conductivity /TDS/salinity/temperature measurement Figure 2
      0~200mS/0.01µS, salinity display 0~80ppt, TDS (can be equipped with 4-ring and 2-ring electrodes)


      When Ren designed the 3020M, we based it on the star model 3010M, increased its range and accuracy, and upgraded it to be compatible with 2/4-wire conductivity electrodes. This product has passed RoHS certification and does not contain any environmentally harmful substances. This product can simultaneously display conductivity/temperature, salinity/temperature, TDS/temperature, and can store up to 50 ratios of data.

      Features

      Simultaneously display conductivity, temperature, salinity, and TDS measurement data

      Up to 50 sets of measurement data can be stored

      Adjustable TDS coefficient, reference temperature, temperature coefficient

      Can be connected to four-wire electrode (K=0.475) and two-wire electrode (K=0.1).

      Automatic shutdown function (after 30 minutes of inactivity)

      Battery life of over 150 hours

      IP-65 waterproof body

      Low battery indicator

      Product display picture

      Display picture of JENCO 3020M portable water quality meter from the United States

      VS

      JENCO 3020M Water quality Measurement InstrumentSpecifications

      LIST VALUE
      Conductivity Measurement Range 0.00uS/cm~200.0mS/cm
      EC resolution 0.01μS/cm,0.1μS/cm,1μS/cm,0.01mS/cm,0.1mS/cm
      EC measurement Accuracy ±0.5%FS
      TDS range 0.00mg/L~200.0g/L
      TDS resolution 0.01mg/L,0.1mg/L,1mg/L,0.01g/L,0.1g/L
      TDS measurement Accuracy ±0.5%FS
      Salinity range 0.0~70.0ppt
      Salinity resolution 0.1ppt
      Salinity measurement Accuracy ±0.2%FS
      Temperature Measurement Range -10.0~90.0℃
      Temperature Resolution 0.1℃
      Temperature measurement Accuracy +/- 0.2 ℃ or +/- 0.4% F.S. Choose a larger value
      reference temperature 15.0~25.0 ℃, default 25.0 ℃
      temperature coefficient 0.00~4.00%, default 1.91%
      TDS conversion factor 0.30~1.00, default 0.65
      Four-wire conductivity electrode K=0.475
      Two-wire conductivity electrode K=0.1
      Automatic temperature compensation Thermistor, 10Kohms (25.0 ℃)
      Data storage 50 sets
      Power 9V battery
      Ambient Temperature 0~50℃
      Working Relative Humidity <90%

      JENCO 3020M Water quality Measurement Instrument Packing list

      Host X1, Four-wire Conductivity detector electrode X1, 9V battery X1, suitcase X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      What is the conductivity of silicon generally measured?
      [A]
      This one is ok.
      [Q]
      The Ren's 3020M water quality tester I bought always shows "OVER". How can I solve it?
      [A]
      Hello, the test shows that there are three reasons: Conductivity detector value exceeds 200.0mS (K = 0.475) ● Conductivity detector value exceeds 200.0uS. (K = 0.1) ● Salinity value exceeds 70.0ppt. Correction method: ● Make sure that the electrode is immersed in the standard solution or the tested solution at least 2~ 3 inches or 5~ 7cm. ● Have enough time to wait for the electrode reading to stabilize. ● Recalibrate with the standard solution. ● Replace the standard solution. ● Clean the Conductivity detector electrode.
      [Q]
      How many kinds of water quality data can JENCO3020M water quality measurement instrument test?
      [A]
      Hello, Ren's water quality measurement instrument 3020M can simultaneously test and display the measurement data of conductivity, temperature, salinity and total solid capacity.
      [Q]
      Can the jenco3020M water quality measurement instrument be used in fish pond breeding?
      [A]
      Hello, it's OK.
      +JENCO 3020M Water quality Measurement Instrument Big data
        +JENCO 3020M Water quality Measurement InstrumentSimilar products
        +JENCO 3020M Water quality Measurement InstrumentKnowledge
        +JENCO 3020M Water quality Measurement InstrumentStandard
        +Navigation
        JENCO
        JENCO 3020M portable Water Quality Meter conductivity /TDS/salinity/temperature measurement
        Service
        Focus on online sales of Lab Testing Instruments