Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Incubator> TaiSiTe> TaiSiTe WPL-230BE Electrothermal Thermostatic Incubator
      TaiSiTe WPL-230BE Electrothermal Thermostatic Incubator

      TAISITE WPL-230BE Electric Thermostatic Incubator 80 ℃/230L

      TAISITE WPL-230BE electrothermal static Incubator liner size 600 * 500 * 750mm, using nickel-chromium alloy heating wire heater, Heating power 0.7KW, WPL-230BE Temperature range RT + 5~ 80 ℃, Temperature Fluctuation +/- 0.5 ℃, using liquid crystal dual column PID temperature control.

      Brand
      SKU: NB029120
      China TaiSiTe
      VS
      TaiSiTeLOGO

      TaiSiTe

      Information
      Genuinegoods
      • TaiSiTe WPL-230BE Electrothermal Thermostatic IncubatorOverview

      • Specifications
      • Comments
      • FAQs
      WPL-230BE
      Electrothermal Thermostatic Incubator

      Benefits:

      • High precision, high efficiency, safety, wide range.

      • Convenient operation, fixed value operation, timed operation, automatic stop.

      • Dedicated function keys enable temperature setting.

      • Auxiliary menu, to achieve over-rise alarm, deviation correction, menu locking.

      • Vertical double air duct air jacket, turbine centrifugal forced air supply, more uniform temperature.

      • Speed-controlled fans enable the use of lightweight, fine, powdery samples.

      • The forced fan dissipates heat and intakes the air structure, so that the maximum working temperature of the fan < 50°C

      • LCD multi-data full-screen operation display, power failure memory, power failure compensation

      • Overlift preventer

      Detail design advantages

      Figure 1: Heating curve: time unit: minutes, temperature unit: °C

      Figure 2: Thickened safety door design: Thickened and heat-insulated safety door design reduces heat dissipation and makes the experiment more comfortable

      Figure 3, multi-function control panel

      WPL series

      ModelRated powerContent volume
      WPL-30BE0.15KW30L
      WPL-45BE0.25KW45L
      WPL-65BE0.5KW65L
      WPL-125BE0.6KW125L
      WPL-230BE0.7KW230L
      Other parameters
      mannerDual air ducts force convection
      Operating temperature range RT+5~80℃  
      Temperature resolution0.1℃
      Temperature fluctuations±0.5 ℃
      Temperature distribution accuracy±1.0℃
      Built-inStainless steel plate   
      ExteriorCold-rolled steel plate, surface resistance * quality coating
      Insulating materialspolyurethane
      Temperature control method LCD double-row PID
      Temperature setting methodTap the four buttons to set it
      Temperature representation Measured temperature display: LCD upper display; Set temperature display: LCD lower display
      timer0~9999 minutes (with timed waiting function)
      Run the functionFixed-value operation, timed operation, automatic stop
      Program modeMatching
      Additional featuresDeviation correction, menu button locking, power failure compensation, power failure memory (overlift preventer)
      clapboard2 pcs
      Partition shelves4 pcs
      Configurations can be addedPartition, RS485 interface, printer, Recorder, external communication, remote control, program thermometer, wireless SMS alarm, U disk data storage
      VS

      TaiSiTe WPL-230BE Electrothermal Thermostatic IncubatorSpecifications

      LIST VALUE
      Temperature range RT+5~80℃
      Temperature Fluctuation ±0.5℃
      Temperature Resolution 0.1℃
      Temperature Uniformity ±1.0℃
      Volume 230L
      Liner size 600*500*750mm
      Liner material stainless steel plate
      Shelf (standard) 2pcs
      Shelf (max.) The 17th floor.
      Load per shelf 15kg
      Timer Range 0~9999min (with Timer and waiting function)
      Power supply Voltage AC 220V/3.2A 50/60Hz
      Input Power 0.7KW
      Dimension 735*625*1220mm
      Net Weight 84kg
      Enclosure Material Cold rolled steel plate, surface resistance painting
      Thermal Insulation Polyurethane
      heater Nickel chromium alloy heating wire
      Exhaust Port Inner diameter 28mm * 2, top
      Temperature Control mode LCD dual row PID
      Temperature setting method Tap the four-button setting
      Temperature representation Measuring temperature display: liquid crystal upper display; setting temperature display: liquid crystal lower display
      Operational Features Fixed value operation, regular operation, automatic stop
      Program control function optional
      Additional features Deviation correction, menu button lock, power outage compensation, power outage memory (over-rise preventer), constant speed fan
      temperature sensor pt100
      packing size 898*814*1347mm
      Shelf spacing 35mm
      Gross Weight 100kg
      Safety Devices Over-rise alarm (over-rise preventer)
      Thermostatic mode Double duct forced convection
      Shelf (standard) 2pcs
      Shelf (standard) 4pcs

      TaiSiTe WPL-230BE Electrothermal Thermostatic Incubator Packing list

      Host X1, operation manual X1, certificate of conformity X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +TaiSiTe WPL-230BE Electrothermal Thermostatic Incubator Big data
        +TaiSiTe WPL-230BE Electrothermal Thermostatic IncubatorSimilar products
        +Navigation
        TaiSiTe
        TAISITE WPL-230BE Electric Thermostatic Incubator 80 ℃/230L
        Service
        Focus on online sales of Lab Testing Instruments