JENCO 9010M portable dissolved oxygen Tester, range: 0.00~20.00mg/L
JENCO 9010M portable dissolved oxygen Tester can display dissolved oxygen, air saturation, temperature value, JENCO 9010M dissolved oxygen value Measurement range of 0.00~20.00mg/L, widely used in aquaculture, river water quality measurement, sewage measurement.
JENCO-
DDKSIC PD100 desktop pH, Dissolved Oxygen Meter pH/mV (ORP electrode optional)/DO/℃
$ 789.00 -
HANNA HI98311 conductivity EC/TDS total solid solubility Measurement Instrument
$ 297.00 -
LEICI 780800N04 residual chlorine/total chlorine/chlorine dioxide kit for DGB-403F
$ 124.00 -
HANNA HI9829-11042 high-precision multiparameter Water Quality Analyzer pH/ORP/EC/DO/turbidity 4 meters probe 230V
$ 8244.00 -
Bante980 laboratory Dissolved Oxygen Meter
$ 467.00
Introduction
The 9010M is a dissolved oxygen Detector that is suitable for general use, easy to use, and can access up to 50 data records. The 9010M uses polarographic detection to obtain data.
Features
Conductivity/salinity or one of the total solids capacity is displayed at the same time as the temperature measurement
Access up to 50 data items
Convenient single-point correction
Automatic temperature compensation of dissolved oxygen data
The user can select salinity and pressure to compensate for the dissolved oxygen data
The polarographic formula has an automatic break
Electric function (after 45 seconds of inactivity)
The battery life is more than 500 hours
IP-65 waterproof enclosure
Low battery indication
This product is RoHS and EU certified
Product display diagram

JENCO 9010M Portable dissolved oxygen TesterSpecifications
| LIST | VALUE |
|---|---|
| DO range | 0.00~20.00ppm |
| DOS resolution | 0.01ppm |
| Accuracy of air saturation | ±0.5%FS |
| Air saturation range | 0.0~200.0% |
| Air saturation resolution | 0.1% |
| Accuracy of air saturation | ±0.5%FS |
| Measurement range | -6.0~46.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | +/- 0.3 ℃ +/- 1 word |
| Pressure compensation range | 600~1100mBar adjustable, the default value is 1013mBar |
| Salinity compensation range | 0.0~40.0ppt adjustable, the default value is 0.0ppt |
| Electrode type | polarography |
| calibration data store | Yes, 50 sets. |
| Automatic temperature compensation | Yes. |
| Power Supply | 9V battery |
| Environmental temperature | 0~50℃ |
| Weight | About 260g (without battery) |
| DO Measurement Accuracy | ± 0.5% FS |
| Working Relative Humidity | <90% |
| size | 186x70x37mm |
JENCO 9010M Portable dissolved oxygen Tester Packing list
Host X1, LD-900-11 electrode X1, LD-900-3A electrode film head X1, 9V battery X1, suitcase X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 9010M dissolved Oxygen Meter instruction manual
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- ActiveJJF 1714-2018
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveHJ 925-2017
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveHJ 2515-2012


9010M