JENCO 6173 laboratory STIP-scan pH oxidation reduction temperature Tester
-6~ 20/0.01 pH, -2000~2000/1mV, manual/automatic temperature compensation -10~120 ℃, two-point correction
JENCO-
JINGQI WD8219 Arsenic Tester
$ 481.00 -
LEICI 782500N02 Total Nitrogen Working Reagent Kit for DGB-401
$ 158.00 -
HANNA HI7032L TDS calibrated solution 1382ppm (mg/L)/500mL
$ 117.00 -
TONGAO TR-782H Water Quality Silica Tester
$ 786.00 -
YUEFENG SZ8112 copper analyzer, copper content analyzer 0~ 2.0mg/L
$ 343.00
Introducing the JENCO 6173/6173R Laboratory Water Quality Tester
The 6173/6173R measures pH, oxidation-reduction potential (ORP), and temperature.
Microcomputer processor, high measurement accuracy and good repeatability.
Ultra-large LCD display, electrode efficiency, temperature display, low battery warning.
AC and DC dual-purpose, universal electrode bracket, easy to operate.
RS-232C communication interface (6173R only)
The 6005P electrode can meet the conventional test and be used with the JENCO series electrode.

Optional
| Model | Introduction |
| 6230AST | Stainless steel temperature probes |
| 600S/600L-ORP | Molded/glass ORP composite electrode (redox potential measurement) |
| GB700E | Refillable glass pH combination electrode (routine measurement) |
| 600P | Molded case pH composite electrode (routine measurement) |
| GB710E | Composite electrodes (glass), viscous or greasy objects, strong acids and alkalis |
| 600C | Composite electrode (glass) (pure water measurement) |
JENCO 6173 STIP-scanSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | -6.00~20.00pH |
| Resolution | 0.01pH |
| Accuracy | ±0.01pH |
| pH correction solution type | (4.01, 7.00 & 10.01) or (4.00, 6.86 & 9.18), user-selected, automatic two-point correction |
| Temperature range of pH correction solution | 0~60.0℃ |
| pH temperature compensation range | -10.0~120.0℃ |
| End point sensing and locking | Yes. |
| Impedance | >10^12Ω |
| Temperature compensation probe | Thermistor 10KΩ (25 ℃) |
| calibration data store | Yes. |
| Communication interface | 6173R Yes, RS-232C; 6173 No |
| Power Supply | Power Supply |
| Environmental temperature | 0~50℃ |
| Dimensions | 230*165*80mm |
| Weight | 650G (without battery) |
| Measurement range mV | -2000~+2000mV |
| mV resolution | 1mV |
| Measurement Accuracy of mV | ±0.05%FS |
| Measurement range | -10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ±0.3℃ |
| Shop Accessories | Stainless steel temperature probe, composite electrode (Glass), viscous or greasy objects, strong acid measurement), plastic/Glass ORP composite electrode (Oxidation-reduction potential measurement), Fillable Glass pH composite electrode (conventional measurement) |
| Shop Accessories | Plastic shell pH composite electrode (conventional measurement), pure water Glass pH composite electrode (pure water, ultrapure water measurement), Glass pH composite electrode (70~100.0 ℃ medium, organic solvent, protein medium measurement) |
| pH temperature compensation | Automatic/manual |
| Working Relative Humidity | <95% |
JENCO 6173 STIP-scan Packing list
Host X1, 6005P electrode X1, 007A universal electrode bracket X1, AC voltage regulator X1, battery X1, correction liquid X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use


6173