Determination of rheological performance of cone-plate viscometer 129.6~ 25920mPa · s
The TOKI RE-85R cone-plate viscometer is an experimental cone-plate Viscometer with a viscosity measurement range of 129.6~ 25920mPa · s, standard 1 '34'xR24 cone rotor, RE-85R full scale torque 1437.4 μN · m, with preheating and automatic stop function, RS232C interface can be connected to the printer.
TOKI-
FANGRUI instrument NDJ-5T Digital Rotational Viscometer with PT100 temperature probe
$ 629.00 -
Fungilab APM Small Capacity Adapter
$ 2216.00 -
NIRUN CPE-52 cone-plate viscometer rotor, shear rate 2.0N
$ 658.00 -
NIRUN 3000 series, standard solution (not sold separately)
$ 192.00 -
Pingxuan RVTV-2H Brinell Viscometer High Temperature Viscometer 10 million mpas
$ 2092.00
Introduction
The R85 viscometer is a viscometer with an automatic locking function in the standard configuration. It is a sister model of the popular R100 series. It is also a new model that combines ease of use and compact design. Of course, the automatic locking function is more reliable, so even novices who are using the viscometer for the first time can make measurements with peace of mind. The R85 model has two measurement methods: a single cylinder viscometer model RB-85 that uses a 500 ml beaker for measurement, and a cone and plate viscometer model RE-85 that can measure only a trace amount of 1 ml sample. Customers can choose the most suitable model according to their respective measurement purposes. In addition, there are .
Features
1.Auto lock
After the measurement is completed, the rotating shaft can be automatically locked to protect the pivot. Therefore, the rotor can be safely detached from the bearing without damaging the bearing. Even novices who use the viscometer for the first time can use it with confidence.
2. Setting of zero point and range
Differences between instruments are compensated during calibration, so the actual usage accuracy is higher than the accuracy stated on the sample.
3. Preheating and automatic stop
It has preheating and automatic stop functions. Preheating can also be used as an automatic start function. With the automatic stop function, the operation and stop of the viscometer can be set at any time.
4.Data exchange
The data measured by the R85 viscometer can be interchanged with other models of single cylinder and cone-plate viscometers produced by our company. It also complies with JIS standards and ISO standards.
5.Power lock
Even if the power switch is turned off during operation, the power will not be turned off until the bearing is locked.
6. Slow acceleration and slow deceleration during rotation
In order to prevent the viscometer from sudden impact, change the rotation speed smoothly when starting, changing, and stopping the measurement.
7.Alarm display
When the measured data is below 10%, or exceeds 100%, an alarm sign will be displayed and an alarm sound will sound.
8. Data recording
The R85 viscometer has a built-in calendar function. In addition to recording measurement data, a special printer can also be used to print the date and viscometer model.
TOKI RE-85R ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital explicit |
| Viscosity range | 129.6~25920 mPa·s |
| Rotor specification | 1''34'xR24 |
| Rotor speed | 0.5rpm、1rpm、2rpm、2.5rpm、4rpm、5rpm、10rpm、20rpm、50rpm、100rpm |
| Reproducibility | ±0.2%F.S |
| Measurement Accuracy | Within +/- 2.0% of full scale |
| Container size | 500ml |
| Power | Input Power Supply (host) DC12V 2A |
| peripheral interface | RS232C port |
| Instrument Weight | 6.0Kg (including base bracket) |
| Operating language | English |
| Environment Operating temperature | 0~40℃ |
| Environment Relative Humidity | Relative Humidity less than 90% (no condensation) |
| Full scale torque | 67.37μN·m |
| Base size | 300*300*450mm |
| current consumption | Below 50VA |
| Dedicated AC adapter | Input AC100~240V +/- 10%; Output DC12V |
| Materials in contact with liquid parts | Steel (SUS304, SUS303) |
| Display information | Viscosity measurement value (optional SI system, CGS system,% value) alarm, swirl/spin series, rotor number, swirl/spin speed and model display |
TOKI RE-85R Viscometer Packing list
Viscometer X1, certificate of conformity, warranty card, manual
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


RE-85R