JENCO 3173R desktop conductivity Tester, detection conductivity /TDS/salinity Tester
0~200mS/cm, TDS range 0~100.0ppt, salinity display 0~80ppt, RS-232C and USB communication function.
JENCO-
DDKSIC PD100T desktop pH, Dissolved Oxygen Meter (touch screen) pH/mV (ORP electrode optional)/DO/℃
$ 929.00 -
HANNA HI98192 Conductivity Meter EC/TDS/Electrical resistivity /NaCl/Temperature professional measurement
$ 1223.00 -
HANNA HI98196/10 Water Quality Analyzer 10 meters long
$ 1969.00 -
TDS Standard 744.7 ppm, 480 ml
$ 102.00 -
HANNA HI764073 Special dissolved Oxygen electrode (built-in temperature sensor)
$ 584.00
Introducing the JENCO 3173R Benchtop Conductivity Meter
3173R conductivity value, total dissolved solids (TDS), salinity, temperature
Microcomputer processor, high measurement accuracy and good repeatability
Extra-large LCD display
Power-off correction plant memory
Automatic temperature compensation
Low battery alert
AC and DC dual-purpose power supply

Optional
| Model | Introduction |
| 107N | K = 10.0 cm-1 conductivity electrode (high conductivity dielectric measurement) |
| 109L | K=01.cm-1 conductivity electrode (pure water, ultrapure water measurement) |
JENCO 3173R Conductivity TesterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.00uS/cm~200.0mS/cm |
| Resolution | 0.01uS/0.1mS |
| Accuracy | ±0.5%FS |
| Types of electrode constants | K=0.1/1.0/10.0 |
| EC Temperature Compensation Range | Automatic -10.0~120.0 ℃ |
| reference temperature | 15.0~25.0 ℃ adjustable, the default value is 25.0 ℃ |
| temperature coefficient | 0.00~4.00% adjustable, the default value is 1.91% |
| Total solids dissolved (TDS) coefficient | 0.5 |
| calibration data store | Yes. |
| Communication interface | RS-232C |
| Power Supply | AC (220V) or 6 5 #batteries (1.5V) |
| Environmental temperature | 0~50℃ |
| Dimensions | 230*165*80mm |
| Weight | 650G (without battery) |
| TDS range | 0.00ppm~100.0ppt |
| TDS resolution | 0.01/0.1ppt |
| TDS Measurement Accuracy | ±0.5%FS |
| Salinity range | 0.0~80.0ppt |
| Salinity resolution | 0.1ppt |
| Measurement Accuracy of salinity | ±1%FS |
| Measurement range | -10.0~120.0℃ |
| Temperature Resolution | 0.1℃ |
| Measurement Accuracy | ±0.5℃ |
| Shop Accessories | K = 0.1 Glass two-wire Conductivity Detector electrode (pure water, ultrapure water measurement), K = 10.0 Glass (outer tube plastic) two-wire Conductivity Detector electrode (high conductivity medium water measurement) |
| Working Relative Humidity | <90% |
JENCO 3173R Conductivity Tester Packing list
Host X1, 106L Conductivity detector electrode X1, 007A universal electrode bracket X1, AC voltage regulator X1, data cable X1, software X1, battery X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Ren's JENCO 3671 pH/ORP Controller Instruction Manual
- Ren's JENCO 3621 Microcomputer pH/ORP Controller Instruction Manual
- Ren's JENCO 3331 Microcomputer Conductivity Detector/resistivity transmitter manual
- Ren's JENCO MODEL 3321 Microcomputer Conductivity Detector/resistivity controller Instructions for use
- Ren's JENCOMODEL 3250M Microcomputer Processing Conductivity Detector/TDS/salinity/temperature Portable measuring instrument Operation manual
- JENCO MODEL 3173 Microcomputer Processing Conductivity Detector Benchtop measuring instrument Instruction manual
- Ren's JENCO 3107 Microcomputer Desktop Conductivity Detector Instruction Manual
- Ren's JENCO ORP 628N Microcomputer Type ORP & Temperature Test Pen Instructions for Use
- Ren's JENCO3010M laboratory conductivity meter instruction manual
- Ren's JENCO692 pH Transmitter Instructions for Use
- ActiveJJF 1565-2016
- ActiveJJG 2059-2014
- ActiveJJF 2105-2024
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveHJ 2515-2012


3173R