      Home> Miscellaneous instruments> hzaoc> hzaoc AK-RJX-9S Mechanical Properties Testing Machine (horizontal)
      hzaoc AK-RJX-9S Mechanical Properties Testing Machine (horizontal)

      HZAOC AK-RJX-9S horizontal Mechanical Properties Testing Machine

      HZAOC Thermal Mechanical Properties Testing Machine AK-RJX-9S Temperature range is -40 ℃~ 80 ℃, Temperature uniformity ≤ +/- 2 ℃, is a horizontal Thermal Mechanical Properties Testing Machine, AK-RJX-9S can be used to test the high-low temperature tensile load performance of insulator materials.

      Brand
      SKU: NB029432
      China hzaoc
      VS
      Genuinegoods
      • hzaoc AK-RJX-9S Mechanical Properties Testing Machine (horizontal)Overview

      • Specifications
      • Comments
      • FAQs
      AK-RJX-9S
      Mechanical Properties Testing Machine (horizontal)

      Applications

      The product is suitable for the performance test of insulator materials under high-low temperature environmental conditions for cooling and heating cycles and tensile load application at the same time.

      Cabinet structure

      1. The structure of the box is customized according to the size of the specimen. 

      2. The inside of the box is made of 1.0mm imported SUS304B stainless steel plate, the outer side is sprayed with 1.0mm cold-rolled steel plate, and the insulation material is made of ultra-fine glass insulation cotton.

      3. The door seal is made of double-layer silicone rubber sealing material.

      4. An air conditioning cabinet is set up in the box studio, and evaporators, electric heaters, fans, fan volutes and other equipment are installed in the middle of it.

      5. The temperature sensor is placed at the air outlet.

      6. The air supply mode in the Test Chamber is the upper air supply and lower return air mode.

      Mechanical performance load system

      It is equipped with a mechanical properties tensile device, and the insulator element bears four 24-hour cooling and heating cycles at the same time, and applies a tensile load, and the size of the load is kept between 60% ~ 65% of the specified electromechanical or mechanical damage load.

      Heating and cooling systems

      1. The heater adopts porcelain frame nickel-chromium wire electric heater, which has low thermal inertia and long life. The controllable pulse duty cycle PID signal is output by the instrument, which is controlled by a solid-state relay, and the control is stable and reliable.

      2. Low-temperature refrigeration adopts French "Taikang" fully enclosed compressor unit. OTHER REFRIGERATION COMPONENTS SUCH AS THE UNITED STATES RANCO, SPORLAN, SWITZERLAND "ALFALAVAL", DENMARK DANFOSS, ITALY CASTEL, JAPAN SAGINOMIYA AND OTHER ORIGINAL IMPORTED PRODUCTS. R404A environmentally friendly refrigerant is used.

      3. In order to ensure the safe operation of the system, it is necessary to set up high-low Voltage control, overpressure, overload and other protection systems in the system. At the same time, in order to monitor the operation of the system, high-low Voltage gauges need to be installed at both the high-low Voltage ends to monitor the operation of the system.

      4. The refrigeration capacity is adjusted by the shunt method.

      Control system

      1. Temperature controller: 7-inch large-screen true-color LCD touch screen temperature controller, accurate and stable control, long-term operation without drifting.

      2. Sensor: PT100 temperature sensor.

      3. The control heating output is triggered by solid-state relay zero-crossing to reduce noise, reduce pollution, facilitate maintenance, and improve control accuracy.

      4. Safety protection measures should be set in the control system, including: phase loss protection, phase sequence error protection, phase Voltage uneven protection, fan overload protection, overtemperature, power-off protection, unit high-Voltage protection, unit overload protection, unit overtemperature protection, leakage and other protection.

      5. The control system is equipped with a user-friendly operation panel, equipped with power supply, lighting, operation buttons for various functions and fault indicators.

      6. In addition to the main controller in the system, an independent over-temperature protector is also set up, even if the main controller fails, the over-temperature protector can reliably disconnect the heating power supply to protect the safety of equipment and samples.

      7. There is an interlock device in the electrical control system, when the circulating fan is not started or overloaded, the refrigeration unit and the heating system can not be started, and the refrigeration unit will be prohibited when the unit is overloaded and overloaded.

      Enforce the standard

      GB/T 22708-2008 Thermal and mechanical properties test of insulator string elements;

      VS

      hzaoc AK-RJX-9S Mechanical Properties Testing Machine (horizontal)Specifications

      LIST VALUE
      Liner size 700 × 600 × 4200Mm (depending on the size of the specimen)
      Temperature range -40℃~80℃
      Temperature Uniformity ≤ +/- 2 ℃ (when no load)
      Temperature Fluctuation ≤ +/- 0.5 ℃ (when no load)
      Cooling rate 0.7~1.0℃/min
      Heating rate 1.0~3.0℃/min
      Specimen mechanical system Mechanical Properties Stretching Device for Insulators (7-55T, Customizable)
      Maximum test force 600KN
      Force resolution 0.01KN
      Force indication Precision Level 1.0
      Displacement scale stroke 600mm
      displacement rate 0~100mm/min
      Time setting range 0~999 hours
      Power supply Voltage AC220V 5KW
      Execution standards GB/T 22708-2008
      Environmental temperature 5 ℃~ + 28 ℃ (average temperature within 24 hours ≤ 28 ℃)
      Environmental humidity ≤85%
      Power supply Voltage AC380 (+/- 10%) V/50HZ three-phase four-wire system
      Operating environment It needs to be below 28 degrees at room temperature and well ventilated; the machine is placed at 80 cm left and right before and after, and nothing can be placed

      hzaoc AK-RJX-9S Mechanical Properties Testing Machine (horizontal) Packing list

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +hzaoc AK-RJX-9S Mechanical Properties Testing Machine (horizontal) Big data
        +Navigation
        hzaoc
        HZAOC AK-RJX-9S horizontal Mechanical Properties Testing Machine
        Service
        Focus on online sales of Lab Testing Instruments